Download Print this page

Troubleshooting; Specifications; Recharging From A Solar Panel; Replacing The Emergency Light Bulb - Duracell 854-1707-07 Instruction Manual

Advertisement

INSTANT JUMPSTART SYSTEM
Disconnect the jumpstart clips from the vehicle's battery and redo
steps 2 and 3 in this procedure.
If no alarm sounds, and the Green Jumpstart Connection LED is
illuminated, then proceed to the next step.
4. Switch ON the Instant Jumpstart System Power Switch.
:
.
CAUTION
EQUIPMENT DAMAGE
Do not recharge the Instant Jumpstart System when an external
battery is connected. The AC charger may be damaged.
To disconnect the jumpstart clips from an external battery and
from the Instant Jumpstart System:
1. Ensure that the Jumpstart Power Switch is OFF.
2. Remove the red positive (+) clip, and then remove the black
negative (–) clip from the external battery terminals.
3. Store the jumpstart clips in the appropriate holder on each side of
the Jumpstart.
4. Recharge the Jumpstart as soon as possible after use.
:
.
CAUTION
EQUIPMENT DAMAGE
When charging for the first time, you must completely charge the
Instant Jumpstart System. This may take up to 48 hours.
If not used for a month, or when recharging after use, charging the
Instant Jumpstart System may take 4-5 hours with vehicle DC or up
to 28 hours with household AC.
Instant Jumpstart System Maintenance
Routine maintenance is required to keep your Jumpstart operating
properly. Occasionally clean the exterior of the unit with a damp cloth
to remove the accumulated dust and dirt.
:
.
WARNING
ENERGY HAZARD
Disconnect all sources of AC power and DC power before
performing any type of maintenance.
Maintaining the Battery
All rechargeable batteries gradually discharge when left standing, and
you need to recharge them periodically to maintain maximum battery
capacity. The AC Charger supplied with the Jumpstart is designed to
regulate the charging process, ensuring that the battery is always fully
charged but never overcharged. To ensure safe recharging and
maximum battery life, recharge the Jumpstart only with the supplied
charger or approved battery chargers.
:
.
CAUTION
INTERNAL BATTERY DAMAGE
Due to inherent self-discharge, lead acid batteries must be charged at
least every month, especially in a warm environment. Leaving a
battery in a discharged state, or not recharging every month, may
result in permanent battery damage and poor jumpstarting
performance.
:
.
CAUTION
INTERNAL BATTERY DAMAGE
Do not attempt to recharge the Instant Jumpstart System battery if it
is frozen. Gradually warm the frozen battery to 0°C (32°F) before
recharging.
Recharging with the AC Charger
See "Recharging with the AC Charger" under "Instant Jumpstart
System Operation".
Recharging Using the DC Charging Cable
:
,
.
ENERGY
SHOCK HAZARD
WARNING
Do not use this recharging method if your vehicle has abnormally
high voltage electrical systems that operate above 15 V DC. This
may lead to accumulations of hydrogen, causing exposure to fire and
explosion hazard.
:
.
EQUIPMENT DAMAGE
CAUTION
Do not operate DC appliances while the Jumpstart is being recharged
with the DC Charging Cable from your vehicle.
Important: Although the charge regulation circuitry in the Jumpstart
does not operate with this charging method, most vehicle voltage
regulators will ensure that the Jumpstart is not overcharged.
1. While the vehicle engine is running, plug one end of the DC
Charging Cable into the DC Power Outlet of the Instant Jumpstart
System.
2. Plug the opposite end of the DC Charging Cable into the vehicle's
lighter socket or 12 V accessory outlet.
3. Once the Instant Jumpstart System is fully charged or if your
vehicle's engine is not running, disconnect the DC Charging Cable
from both sockets. Most of the Instant Jumpstart System's capacity
will be restored in 2 ½ hours while the vehicle engine is running.
Note: The Battery Status LED will not illuminate when the Jumpstart
is recharged through the DC Charging Cable.
Important: Do not leave the Instant Jumpstart System permanently
connected to the vehicle's lighter socket or 12 V accessory outlet.
Recharging with a Generator's Regulated 12 V DC
Outlet
Refer to the Owner's Guide accompanying your generator for detailed
instructions on connecting a 12V load, like the jumpstart, to your
generator.
:
,
.
WARNING
FIRE
EXPLOSION HAZARD
The generator output must be intended for battery charging and have
an output of 15 V or less. An unregulated output or one that exceeds
15 V DC can damage the battery.
This may lead to accumulations of hydrogen, causing exposure to
fire and explosion hazard.
You can recharge using a generator in several ways:
• Using the AC Charger to recharge the Jumpstart from a generator
is possible, but would require extended generator running time.
• Using a generator which has an auxiliary regulated 12 V DC
output designed for charging 12 V DC batteries. Most generators
are equipped with them. Use this power source for faster charging.
• Using a generator with a regulated 12 V DC lighter socket. Follow
the connection instructions in "Recharging Using the DC Charging
Cable".

Recharging from a Solar Panel

Small, unregulated 12 V solar panels rated to produce a maximum of
2.5 A (or 30 W) can be used to charge the Jumpstart through the AC
Charger Input Socket. You will need to purchase a standard 5.5 mm
OD × 2.5 mm ID (0.217 × 0.10") coaxial DC (barrel type centre
positive) connector to mate with the AC Charger Input Socket. These
connectors are available at consumer electronics stores.
1. Connect the solar panel's red positive (+) wire to the coaxial plug's
inner or centre contact.
2. Connect the solar panel's black negative (–) wire to the plug's
outer contact.
Once the connector is inserted into the AC Charger Input Socket and
the solar panel is placed in the sun, the Jumpstart charges
automatically just as with the AC Charger. It takes about six hours in
direct sunlight to recharge the Jumpstart from a 2.5 A solar panel.

Replacing the Emergency Light Bulb

1. Turn the flashlight switch off.
2. Pop out the plastic lens cover.
3. Gently grasp the bulb and twist clockwise to unscrew the bulb.
Note: There's a triangular notch at the neck of the bulb which
should align with the reflector assembly's bulb socket collar.
4. Insert a replacement bulb of the same type and rating into the light
reflector assembly.
5. Gently grasp the bulb and twist counter-clockwise to screw the
bulb in.
6. Snap in the lens cover.
Recycling
If it's rechargeable, it's recyclable!
Battery-Biz is committed to environmental responsibility and has
established a program for recycling Duracell rechargeable
battery-related products.
For instructions on how to recycle this product visit www.rbrc.org

Troubleshooting

PROBLEM: Portable device or emergency light will not operate.
Possible cause
Remedy
Portable device connected
Portable device exceeds Instant
has a high startup surge.
Jumpstart System surge capability, do
not use.
The Instant Jumpstart
Unplug all devices connected to the 12
System has overheated
V DC power supply socket and switch
due to poor ventilation.
off the flashlight. Allow the Instant
Jumpstart System to cool for 15
minutes. Remove objects covering the
Instant Jumpstart System. Move the
Instant Jumpstart System to a cooler
place.
Product(s) connected are
Unplug the product that is causing the
rated at more than the
overload. Check the 15 A fuse. If it is
Instant Jumpstart
blown or damaged, replace it with a
System's continuous
similarly rated fuse (15 A, 32 V). Use a
power rating.
product with a power rating less than
the Instant Jumpstart System's
continuous power rating.
Instant Jumpstart System
Recharge Instant Jumpstart System.
battery is completely
discharged.
PROBLEM: Instant Jumpstart System will not jumpstart a vehicle.
Possible cause
Remedy
Instant Jumpstart System
Recharge Instant Jumpstart System.
battery is completely
discharged.
Vehicle battery is heavily
Replace vehicle battery.
discharged or sulfated.
Vehicle has 6 V or 24 V
Instant Jumpstart System is not
electrical system.
designed to jumpstart these vehicles.
PROBLEM: Instant Jumpstart System will not charge.
Possible cause
Remedy
The input charging
Replace charger.
voltage is out of range
(charger is defective).
Vehicle battery is
Recharge vehicle battery.
completely discharged (if
recharging with vehicle
DC).
Possible cause
Remedy
AC Charger is faulty or
Replace the AC Charger or make sure
there is no power at the
there is power available at the AC wall
AC wall outlet.
outlet.

Specifications

Specifications are subject to change without notice.
12 V DC Section
Internal battery type
Sealed, AGM (Absorbed
Glass Mat) lead-acid
Internal battery voltage (nominal) 12 V DC
Internal battery capacity (min.)
17 Ah
Internal battery current rating
170 CCA/400 CA
DC output current (max.)
15 A (fuse protected)
Replaceable Incandescent Bulb
12 V, 3–5 W
Internal Battery Charging
Charging current (nominal)
350 mA
Charging voltage (nominal)
13.8 V
AC Charger input socket
2.5 A
maximum current
Operating temperature range
0–40ºC (32–104ºF)
Storage temperature range
0–30ºC (32–86ºF)
Physical Specifications
Dimensions (L × W × H)
9 × 7 1/2 × 12 3/4 in.
(22.86 × 19.05 × 32.38 cm)
W
e
g i
t h
4 1
4 .
b l
6 (
5 .
k
) g
Accessories
DC charge cable
30" (76 cm) 18 AWG with male to
(Part no. 448-0156-01-01)
male lighter plug
AC Charger
Input: 100-240 Vac, 50/60 Hz, 250 mA
(Part no. 074-1019-04)
Output: 14.5 Vdc, 350 mA
Warranty and Return
Quality Guarantee
Battery-Biz guarantees each Duracell® product to be free of defects
due to faulty materials or workmanship. This Duracell® product
carries a 1-year limited warranty from the date of purchase.
If found to be defective, this Duracell® product will be replaced
without charge when returned to Battery-Biz. This guarantee does not
apply to damage from misuse or abuse beyond normal usage. This
guarantee gives you specific legal rights, and you may also have other
rights which vary from state to state. Should any device be damaged
by this product due to defects in the product arising from faulty
materials or workmanship, Battery-Biz will repair or replace (at our
option) the device, provided both device and product usage instruc-
tions have been followed.
Send device with the product to:
Battery-Biz Inc.
1380 Flynn Road, Camarillo, CA 93012
Attention: Duracell Product Returns
If you would like additional information on Duracell products call
1-800-842-2127 or 1-805-437-7765 (7:30 AM-4:30 PM PST).
975-0354-01-01 Revision 2010308
Contacting Customer Support
If you experience any problems or have any questions regarding your
DURACELL® product, free technical support is available. Prior to
calling, please review the technical support tips below.
• Call from a phone where you have access to your mobile
device
• Be prepared to provide the following information:
- Name, address and telephone number
- Name of the DURACELL® product
- Make and model of your device
- Symptoms of the problem(s) and what led to them
Technical Support is available by telephone
- U.S. and Canada (800) 842-2127
- Outside of the US/Canada: (805) 437-7765
Written inquires should be directed to:
Battery-Biz Inc.
DURACELL Product Inquiry
1380 Flynn Road,
Camarillo, CA 93012, USA
One Year Limited Warranty
This product carries a limited warranty against defects in material
and workmanship under normal use and service for one year from
the original date of purchase. The manufacturer or distributor, at its
option, shall repair or replace the defective unit covered by this
warranty. Please retain the dated sales receipt as evidence of the date
of purchase as it will be required for any warranty service. In order
to keep the warranty in effect, the product must have been handled
and used as described in the instructions accompanying this
warranty. This warranty does not cover any damage due to accident,
misuse, abuse or negligence.
Disclaimer Of Warranty
The limited warranty described herein is your sole remedy. To the
extent permitted by law, the manufacturer and distributor disclaim all
other implied or express warranties including all warranties of
merchantability and/or fitness for any particular purpose.
Limitation Of Liability
Except to the extent of repairing or replacing this product as
expressly stated in the limited warranty described herein, the
manufacturer and distributor shall not be liable for any damages,
whether direct, indirect, incidental, special, consequential,
exemplary, or otherwise, including lost revenues, lost profits, loss of
use of software, loss or recovery of data, rental of replacement
equipment, downtime, damage to property, and third-party claims,
arising out of any theory of recovery, including statutory, contract or
tort. Not withstanding the term of any limited or implied warranty, or
in the event that any limited warranty fails of its essential purpose, in
no event will the manufacturer's and distributor's entire liability
exceed the purchase price of this product. Some states and provinces
do not allow the exclusion or limitation of incidental or consequen-
tial damages so the above limitations or exclusions may not apply to
you. This limited warranty gives you specific legal rights. You may
have other rights which vary from state to state and province to
province.
©2010 Duracell. DURACELL® is a registered trademark of The Gillette Company, used
under license. All rights reserved. All logos and trademarks are used for identification
purposes only and may be trademarks or registered trademarks of their respective holders.

Advertisement

loading