Osaka OF 33 Z Operating Instructions Manual

Osaka OF 33 Z Operating Instructions Manual

Microprocessor-based digital electronic freezer controller

Advertisement

OF 33 Z / OF 33 AZ
MICROPROCESSOR-BASED
DIGITAL ELECTRONIC FREEZER
CONTROLLER

OPERATING INSTRUCTIONS

FOREWORD
This manual contains the information necessary for the product
to be installed correctly and also instructions for its
maintenance and use; we therefore recommend that the utmost
attention is paid to the following instructions.
Though this manual has been issued with the greatest care,
OSAKA will not take any responsibility deriving from its use.
The same applies to each person or Company involved in the
issuing of this manual.
This document is the exclusive property of OSAKA which
forbids any reproduction and divulgation , even in part, of the
document, unless expressly authorized.
OSAKA reserves the right to make any formal or functional
changes at any moment and without any notice.
INDEX
1
INSTRUMENT DESCRIPTION
1.1
GENERAL DESCRIPTION
1.2
FRONT PANEL DESCRIPTION
2
PROGRAMMING
2.1
PROGRAMMING OF SET POINT
2.2
PARAMETERS PROGRAMMING
2.3
PARAMETER
PASSWORD
2.4
PARAMETERS PROGRAMMING LEVEL
2.5
ACTIVE SET POINT SELECTION
2.6
ON / STAND-BY FUNCTION
2.7
CLOCK PROGRAMMING
3
INFORMATION ON INSTALLATION AND USE
3.1
PERMITTED USE
3.2
MECHANICAL MOUNTING
3.3
ELECTRICAL CONNECTIONS
3.4
ELECTRICAL WIRING DIAGRAM
4
FUNCTIONS
4.1
MEASURING AND VISUALIZATION
4.2
OUTPUTS CONFIGURATION
4.3
TEMPERATURE CONTROL
4.4
CONTINUOUS CYCLE FUNCTION
4.5
COMPRESSOR PROTECTION FUNCTION AND AND
DELAY AT POWER-ON
PROTECTION
USING
OSAKA - OF 33 AZ - OPERATING INSTRUCTIONS - Vr. 01 - PAG. 1
4.6
DEFROST CONTROL
4.7
MANUAL DEFROST
4.8
EVAPORATOR FANS CONTROL
4.9
ALARM FUNCTIONS
4.9.1 TEMPERATURE ALARMS
4.9.2 EXTERNAL ALARM
4.9.3 OPEN DOOR ALARM
4.9.4 ALARM MEMORY
4.10
DIGITAL INPUT
4.11
AUXILIARY OUTPUT
FUNCTION OF KEYS "F" AND "DOWN/AUX"
4.12
4.13
KEY USB + OSAKA SETUP: KEY PROGRAMMING
5
PROGRAMMABLE PARAMETERS TABLE
6
PROBLEMS , MAINTENANCE AND GUARANTEE
6.1
SIGNALLING
6.2
CLEANING
6.3
GUARANTEE AND REPAIRS
7
TECHNICAL DATA
7.1
ELECTRICAL DATA
7.2
MECHANICAL DATA
7.3
MECHANICAL DIMENSIONS, PANEL CUT-OUT AND
MOUNTING
7.4
FUNCTIONAL DATA
1 - INSTRUMENT DESCRIPTION
1.1 - GENERAL DESCRIPTION
The model OF 33 AZ is a digital controller with microprocessor
that is typically used in cooling applications that have
temperature control with ON/OFF regulation and defrosting
control with set time and hours intervals (Real Time Clock
Defrosting) by means of electrical heating or hot gas/cycle
inversion.
The instrument has 3 relay outputs, two inputs for PTC or NTC
temperature probes and a digital input, that can all be
configured.
The 3 outputs can be used for controlling the compressor or the
temperature control device (OUT), the defrosting device (DEF),
the evaporation fan (FAN) or, alternatively any of the previous
functions, using an auxiliary device (AUX) or an alarm (AL).
The two inputs for the PTC and NTC temperature probes
(which can be selected by parameter) can be used to measure
the cell temperature (Pr1) and the evaporator temperature (Pr2)
while the digital input (DIG) can be programmed to carry out
various functions such as defrosting commands, selecting a
different set of temperature regulations, external alarm signals,
activating a continuous cycle, and activating an auxiliary output
etc.
The instrument is equipped with 4 programme keys, a 4-digit
display and 9 LED signals, in addition to an internal buzzer that
is the sound system for alarms.
Other
important
programme
password, switching on and off (stand-by) of the instrument
using the front keys or the digital input,
parameters via the COPY KEY device, memorising of two sets
THE
of temperature regulations that can be switched and the
possibility of power supply in the range 100 ... 240 VAC.
1.2 - FRONT PANEL DESCRIPTION
characteristics
of
parameters
protection
the
instrument
are:
using
personalised
configuration of

Advertisement

Table of Contents
loading

Summary of Contents for Osaka OF 33 Z

  • Page 1: Operating Instructions

    MECHANICAL MOUNTING ELECTRICAL CONNECTIONS ELECTRICAL WIRING DIAGRAM FUNCTIONS MEASURING AND VISUALIZATION OUTPUTS CONFIGURATION TEMPERATURE CONTROL CONTINUOUS CYCLE FUNCTION COMPRESSOR PROTECTION FUNCTION AND AND DELAY AT POWER-ON OSAKA - OF 33 AZ - OPERATING INSTRUCTIONS - Vr. 01 - PAG. 1...
  • Page 2: Programming

    The instrument allows up to 2 different regulation Set points to be pre-set (“SP 1” and “SP 2”) and then to choose which one to make active. OSAKA - OF 33 AZ - OPERATING INSTRUCTIONS - Vr. 01 - PAG. 2...
  • Page 3: On / Stand-By Function

    (defrost food or changes in their ideal state), it is recalled that the facility should be OSAKA - OF 33 AZ - OPERATING INSTRUCTIONS - Vr. 01 - PAG. 3...
  • Page 4: Electrical Wiring Diagram

    (as for activation). sounds. The continuous cycle function cannot be activated during defrosting and with "tCC" = OFF. OSAKA - OF 33 AZ - OPERATING INSTRUCTIONS - Vr. 01 - PAG. 4...
  • Page 5: Defrost Control

    “Out” should take place, this does not take place and it is signalled by the flashing of the Out led. OSAKA - OF 33 AZ - OPERATING INSTRUCTIONS - Vr. 01 - PAG. 5...
  • Page 6: Manual Defrost

    The relative differential that can be set in parameter “dF” is on the instrument if the instrument is in alarm status when it is also associated with these parameters. switched on. OSAKA - OF 33 AZ - OPERATING INSTRUCTIONS - Vr. 01 - PAG. 6...
  • Page 7: Digital Input

    = -3 - continuous cycle start-up command with contact normally The instrument offers the possibility of arranging the alarm closed : similar to “diF”=3 but with function logic reversed. memory function via the parameter “tAL”. OSAKA - OF 33 AZ - OPERATING INSTRUCTIONS - Vr. 01 - PAG. 7...
  • Page 8: Auxiliary Output

    = 0 - The key carries out no function. = 1 - Pressing the key for at least 1 second, it is possible to enable/disable the auxiliary output if configured (“FOA”=2). OSAKA - OF 33 AZ - OPERATING INSTRUCTIONS - Vr. 01 - PAG. 8...
  • Page 9: Programmable Parameters Table

    23.59 hrs.min LAL Low temperature Alarm OFF / - 58 ÷ dF 5 Time start defrost 5 OFF - 00.00 ÷ threshold 302 °C/°F 23.59 hrs.min OSAKA - OF 33 AZ - OPERATING INSTRUCTIONS - Vr. 01 - PAG. 9...
  • Page 10: Problems , Maintenance And Guarantee

    Minimum temperature alarm in progress 61 Out2 Configuration of output OFF/Out/dEF/ function OUT2: FAn/AuS/ALt/ Digital input alarm in progress see “Out1” AL/ALL/ -ALt/ - Door open AL/ -ALL OSAKA - OF 33 AZ - OPERATING INSTRUCTIONS - Vr. 01 - PAG. 10...
  • Page 11: Cleaning

    Operating temperature: 0 ... 50 °C directive LV 73/23 and 93/68 (EN 61010-1) Operating humidity: 30 ... 95 RH% without condensation Storage temperature: -10 ... +60 °C OSAKA - OF 33 AZ - OPERATING INSTRUCTIONS - Vr. 01 - PAG. 11...

This manual is also suitable for:

Of 33 az

Table of Contents