Alarm Panel configuration changes. This handbook details the operation, connection and functionality of the SafeDial Wireless device, and the SafeDial Toolbox and Pocket Secure applications. There is a separate handbook detailing the operation of SafeDial Config.
PC, tablet or smartphone using SafeDial Toolbox. Ability to remotely arm & disarm Alarm Panels from your smartphone via the Pocket Secure App. Ability to remotely upload/download Alarm Panel configuration from your PC via SafeDial Config. Up to 14.4K band Modem for upload/download.
SafeDial Toolbox App on your smartphone, PC or tablet. Go to www.safedialtoolbox.com.au to activate your unit. NOTE: Refer to the SafeDial Toolbox Quick Start Guide or Page 22 – “Activating a GL45-3G” in this manual. Installation and Commissioning Procedure ...
The outputs can be Opened, Closed or Pulsed remotely using the SafeDial Toolbox App. Ensure there is a common negative between the GL45-3G and the device being switched. Output 1 is typically used for arming / didarming the Alarm Panel via Pocket Secure.
SafeDial Wireless GL45-3G - GL V1.0 / PM V3 Connection Guide to Alarm Panel LED Status Indicators GL45-3G ACTIVITY INDICATION Green Flash * Signal Strength OK / Processor OK Red Flash Signal Strength low or trying to reconnect MOBILE...
Background Polling Health Check polls are sent from the server to the GL45-3G at continuous intervals (typically every 20 minutes on 3G/GPRS and every minute on IP). The poll time in the server is reset after every received poll. If no poll is received for a consecutive 4 hours on either the IP path or 3G/GPRS path, a “Poll Fail” or “Off Line”...
All users can interrogate their SafeDial Wireless outstations remotely for installation, commissioning, diagnostic and control purposes. SafeDial Toolbox has been optimised to run on any touch screen phone, PC, tablet or iPad. To access SafeDial Toolbox, simply go to www.safedialtoolbox.com.au You will be prompted to enter your issued email address and password.
SafeDial Wireless GL45-3G - GL V1.0 / PM V3 NOTES: 1) If you enter the wrong password three times SafeDial will send your password to your registered email. 2) Anywhere within the application that you see , hover over the icon for more information about a particular field.
To ping a unit enter the name serial or account number into text box and click “Ping”. The Serial field is the unique Serial Number of the SafeDial Wireless unit. The serial number can be found on the back of the product prior to mounting, or on the lid of the box the unit is shipped in.
Page 13
Dialler Interface = Will return either OK or Failed status. This is the dialler lead between the Alarm Panel and the GL45-3G. A four wire connection is required between the Alarm Panel dialler and the GL45-3G. ‘Ring” (R) (Red) & ‘Tip’ (T) (Green) as the input and ‘R1’ (Black) & ‘T1’ (Yellow) as the return line.
Page 14
The inputs status will be displayed as either OK or Violated. Addtionally, the Input/Output tab provides functionality to Default the Unit. By selecting the “Default Unit” button, the SafeDial Wireless unit will be reset and loaded with its default settings. Page 14 ...
Page 15
SafeDial Wireless GL45-3G - GL V1.0 / PM V3 d) IP Tab The IP Tab displays the IP addresses and applicable configuration that the unit obtains when IP is connected. You can manually change any of these settings and then click “update” to write this information to the unit.
Uploading and Downloading configurations to your Alarm Panel can be done using Globe’s SafeDial Config utility software. Uploading / Downloading consumes bandwidth over the 3G/GPRS network and therefore we limit the number of times you can do this in a given month to two (2). These are referred to as Panel Client Software downloads.
CSV file for data manipulation, reporting etc. The Fleet tab is where you activate your GL45-3G units, please refer to Page 22 “Activating a GL45-3G” of this manual for detailed instructions.
The Activate Page is for use by Permaconn clients only. Safedial Toolbox is dual use and allows both Globe and Permaconn activations under the one log in. This page is not applicable to the activation or interrogation of Globe GL45-3G devices.
SafeDial Wireless GL45-3G - GL V1.0 / PM V3 8 Users Page The User Page allows you to Create, Edit, View, Delete or SMS users under your fleet. When you open this page your users are sorted by their access levels. You can view each access level via the use of the drop down box (in this example “Control Room Operators”...
The Central Station page shows all of your Control Rooms that you are assigned to. For the GL45-3G devices the Central Station is always “Globe Wireless”. If you are a Permaconn user, the Central Stations you have Permaconn units assigned to will also show in the top list.
Before applying power to the unit, activation must be completed via the SafeDial Toolbox App. 1 Go to https://safedial.permaconn.com on your PC, tablet or smartphone to arrive at the login portal. Login using the “Email” and “Password” sent with your order confirmation. [Screen 1] 2 Once you sign in, you will be greeted with the Ping tab.
To toggle the state of the alarm, the app presents an interface to pulse output 1 on the SafeDial Wireless unit in the field. This then forces the app to wait until the next open/close event is sent and updates the app...
1. Program a zone on the Alarm Panel to be a ‘key switch’ zone. 2. Pocket Secure pulses output 1 on the GL45-3G, so wire output 1 to the programmed ‘key switch’ zone. Output 1 is normally open switching to negative.
3 Enter the details of the user you wish to set up for Pocket Secure (remote Arm & Disarm of the alarm). The email address you use cannot be the same as an email address already used as a login to SafeDial Toolbox. An entry table will appear. [Screen 3] Enter the following details: –...
A. Contact ID messages shaded in green indicate that messages are being processed but not yet completed / delivered to the Control Room. Q. How do I know if the messages are being generated by the Alarm Panel or the SafeDial Wireless unit? A.
Page 26
Whenever the Alarm Panel dials out, pins 1 and 5 are temporarily disconnected by the Alarm Panel. If this 48v DC loop is broken for more than 90 seconds the GL45-3G unit will report a ‘Dialler Lead Fail’ to the Control Room.
Page 27
1 & 2, and do the same for pins 5 & 6. If CID light changes from [RED – ON] to either [GREEN – ON] or [OFF], (depending if the GL45-3G unit has processed any CID events from the alarm panel), the Globe fly lead and the GL45-3G hardware is ok.
THE EARTHING TERMINAL MUST BE PERMANENTLY CONNECTED TO EARTH The unit must only be operated with the supplied antenna. Install the GL45-3G in a location that no person[s] is closer than 200 mm to the antenna at all times.
Need help?
Do you have a question about the GL45-3G and is the answer not in the manual?
Questions and answers