This manual is intended only for use by a qualifi ed heating installer/technician. Read and follow this manual, all supplements and
related instructional information provided with the boiler. Install, start and service the boiler only in the sequence and methods
given in these instructions. Failure to do so can result in severe personal injury, death or substantial property damage.
Do not use the boiler during construction. Construction dust and particulate, particularly drywall dust, will cause contamination
of the burner, resulting in possible severe personal injury, death or substantial property damage. The boiler can only be operated with
a dust-free air supply. Follow the instruction manual procedures to duct air to the boiler air intake. If the boiler has been contaminated
by operation with contaminated air, follow the instruction manual guidelines to clean, repair or replace the boiler if necessary.
Affi x these instructions near to the boiler. Instruct the building owner to retain the instructions for future use by a qualifi ed service
technician, and to follow all guidelines in the User's Information Manual.
Condensing,
High Effi ciency
Water Heaters (IW)
and Boilers (IB)
User's
Information
Manual
Read all instructions thoroughly,
and perform regular maintenance
and service as directed. Keep this
manual on or near the boiler.
62417021 R00 Feb. 18, 2014
UMIE2-1
82-0148

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Infinite Energy 2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for RBI Infinite Energy 2

  • Page 1 UMIE2-1 82-0148 Condensing, High Effi ciency Water Heaters (IW) and Boilers (IB) User’s Information Manual Read all instructions thoroughly, and perform regular maintenance and service as directed. Keep this manual on or near the boiler. 62417021 R00 Feb. 18, 2014 This manual is intended only for use by a qualifi...
  • Page 2: Safety Instructions

    SAFETY INSTRUCTIONS WARNING: If the information in these instructions is not followed exactly, a fi re or explosion may result causing property damage, personal injury or death. - Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 4 AVERTISSMENT: Assurez vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incendie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort - Ne pas entreposer ni utiliser d’essence ou ni d’autres vapeurs ou liquides infl...
  • Page 5 SAFETY INSTRUCTIONS...
  • Page 6 SAFETY INSTRUCTIONS could result in excessive levels WARNING!!! WARNING!!! of carbon monoxide which can When cause severe personal injury or Maintenance: at least once a servicing heater, to avoid death! year the user must call a electric shock, disconnect Qualifi ed installer for routine electrical supply before WARNING!!! maintenance.
  • Page 7 SAFETY INSTRUCTIONS NOTICE! The manufacturer declines WARNING!!! all liability, contractual or otherwise Do not use (warranty included), for any this appliance if any part has damage to people, animals been under water. Immediately property or this same appliance, call a licensed authorized caused by: technician to inspect the a) - incorrect installation;...
  • Page 8: Table Of Contents

    TABLE OF CONTENTS SAFETY INSTRUCTIONS .........................2 TABLE OF CONTENTS ........................8 1 - CODE REQUIREMENTS ......................9 1.1 - Regulations and guidelines ..........................9 2 - GENERAL INFORMATION ......................10 2.1 - Key to symbols used ............................10 2.2 - Manufactured by ..............................10 2.3 - Description of models: ............................
  • Page 9: Code Requirements

    1 - CODE REQUIREMENTS 1.1 - Regulations and guidelines - The installation must conform to the requirements of the authority having jurisdiction or, in the absence of such requirements, to: - the latest edition of the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and or CAN/ CSA B149.1, Natural Gas and Propane Installation Code;...
  • Page 10: General Information

     Important indication symbol 2.2 - Manufactured by RBI WATER HEATER 7555 Tranmere Drive Mississauga, Ontario L5S 1L4 Canada Phone: (905) 670-5888 Fax: (905) 670-5782 www.rbiwaterheaters.com 2.3 - Description of...
  • Page 11: Function Overview

    3 - FUNCTION OVERVIEW 3.1 - Intended use to 98% (IB boiler and functions only) Section applicable to boiler version only. When the outdoor reset is activated (an 3.1.1 Intended use and outside sensor is connected), the boiler functions of the IB boiler always work at the maximum effi...
  • Page 12: Installation - Vent And Combustion Air

    4 - INSTALLATION - Vent and combustion air 4.1 - Prevent combustion air contamination Do not terminate vent/air in locations that can allow contamination of combustion air. WARNING!!! Contaminate combustion air will damage the boiler, resulting in possible severe personal injury, death or substantial property damage.
  • Page 13: Use

    5 - USE 020010.01.023 A - Key to reduce the supply water temperature; B - Multifunctional key: reset any lockouts; access to user and installer menu. C - Key to increase the supply water temperature; D - Flame icon, is present when the fl ame is present; E - Radiator icon.
  • Page 14: Overview

    5 - USE   temperature you have to use keys 5.1 - Overview fail ( ) that blink. The heater is pre-set with standard . When the keys parameters. It is possible to consult Press the RESET key in order to re- are pressed, the display, item “N”...
  • Page 15: Delays, Alarms And Protective Actions

    5 - USE Once the heater has reached a 5.7 - Delays, alarms temperature of 50 °F (10 °C), the and protective heating pump will automatically comes on. If the temperature falls actions below 41 °F (5 °C), the burner will light to prevent the heater from To protect the life of the appliance, freezing.
  • Page 16: Users' Menu

    5 - USE start showing parameters from 1000. For unit models 399 up to 1000 5.11 - “Users’ parameters adressed to “Burner 1” Press keys menu” are applicable for that burner only. can scroll all parameters inside this Pressing RESET key for 2 seconds, menu.
  • Page 17: Diagnostic

    5 - USE 5.12 - Diagnostic During normal operation display can show the below informations: Parameter Parameter description Visualization on display “N” (see Figure 5-1) AFro Heater is doing antifreezing protection Supply temperature (°F) Light fi xed = Indirect water heater enabled Supply temperature (°F) Blinking = indirect water heater loading Light fi...
  • Page 18: Maintenance

    6 - MAINTENANCE 6.1 - Care and performing any maintenance operations, shut the boiler off, maintenance close the manual gas shut-off This section must be brought to the valve and shut off electrical attention of the user by the installer so power to the heater.
  • Page 19: Annual Startup

    Service and maintenance schedules Service Technician User maintenance Daily: Annual Startup: - Check heater area (Follow section 6.1.2); - Address reported problems; - Check pressure gauge (Follow section 6.1.3); - Check all piping for gas leaks; - Verify fl ue and air lines in good condition and sealed tight; - Check system water pressure/system piping/expansion tank;...
  • Page 20: Check Relief Valve

    6 - MAINTENANCE 6.1.1 - Check relief valve away from contaminated areas. Inspect the relief valve and lift the 1. Combustible/fl ammable materials -- lever to verify fl ow. Before operating Do not store combustible materials, any relief valve, ensure that it is piped gasoline or any other fl...
  • Page 21: Check Air Piping

    6 - MAINTENANCE 6.1.5 - Check air piping 6.1.10 - Reset low water 1. Visually inspect the air inlet cut off button (If used) termination to be sure it is Testing the low water cutoff shuts the unobstructed. Inspect the entire unit off.
  • Page 22 NOTE...
  • Page 23 NOTE...
  • Page 24 260 North Elm Street 7555 Tranmere Drive Westfi eld, MA 01085 Mississauga, Ontario L5S 1L4 Canada Phone: (413) 568-9571 Phone: (905) 670-5888 Fax: (413) 568-9613 Fax: (905) 670-5782 www.rbiwaterheaters.com...

Table of Contents