12. Default Value in Adjustment mode
12-1. Auto Color Balance
<Component>
<AV>
(Fig. 7) Default on OSD
12-2. Write Balance
(Fig. 8) Default on OSD
Copyright©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
13. EEPROM Data Write(Serial No D/L)
13-1. Signal TABLE
<RGB>
CMD LENGTH ADH ADL DATA_1
CMD
LENGTH : 85~94h (1~16 bytes)
ADH
ADL
Data
CS
Delay
13-2. Command Set
No
1 EEPROM WRITE A0h
* Description
13-3. Method & Notice
14. Set Information
14-1. Setting up 'Tool Option1,2'
42PG6500
- 12 -
: A0h
2
: E
PROM Sub Address high (00~1F)
2
: E
PROM Sub Address low (00~FF)
: Write data
: CMD + LENGTH + ADH + ADL + Data_1 + ... + Data_n
: 20ms
Adjust mode
CMD(hex) LENGTH(hex)
FOS Default write : <7mode data> write
Vtotal, V_Frequency, Sync_Polarity, Htotal, Hstart, Vstart, 0, Phase
Data write : Model Name and Serial Number write in EEPROM,.
(1) Serial number D/L is using of scan equipment.
(2) Setting of scan equipment operated by Manufacturing
Technology Group.
(3) Serial number D/L must be conformed when it is produced
in production line, because serial number D/L is mandatory
by D-book 4.0.
(Serial No& Model name, Option Table)
(After setting white balance, this is set)
(Setting: Press ADJ Key in the Adjust remocon)
(1) Press ADJ Key in the R/C for adjustment.
(2) Insert Option value by a number key.
(3) Press the Enter Button.
Model
Tool
Tool
Area
Name
Option1
Option2
Option
10240 1697
...
DATA_n
CS DELAY
Description
84h+n
n-byted Write
(n=1~16)
Option1 Option2 Option3 Option4
0
14
2
1
LGE Internal Use Only
192