Keypad User Menu The keypad also provides a User Menu containing all of the functions you need to fully operate your system, such as the ability to change a personal user code number. www.PDF-Zoo.com XRSuper6 Introduction...
For example, the windows on the east side of the all the doors and windows on the outside of the building. When premises can all be grouped together in a zone named E. you arm the Perimeter, these zones sound an alarm if tripped. WINDOWS. www.PDF-Zoo.com XRSuper6 Introduction...
The system sounds the alarm sirens for 15 seconds to alert you of the condition and provide an opportunity for you to close the door. The Exit Error feature allows the central station to acknowledge the arming error without dispatching the police on a false alarm. www.PDF-Zoo.com XRSuper6 Introduction...
Select key under choices being shown in the At SET VOLUME LEVEL, use the left Select key to lower the display. keypad volume and the right Select key to raise the volume. Press the Back Arrow key to exit the User Options menu. www.PDF-Zoo.com XRSuper6 Introduction...
Select keys. This only silences the keypad and does not correct the condition that There is an electronic failure in your system. Contact the service originally caused the problem. department as soon as possible. www.PDF-Zoo.com XRSuper6 Introduction...
LOCAL ALARM ONLY before displaying the armed message. Arming Report: Your system can be programmed to send arming or zone bypass reports to a central station. This feature is optional and can be programmed for you at any time. www.PDF-Zoo.com XRSuper6 Introduction...
5. When the system is fully armed, the keypad displays PERIMETER provided and an alarm will occur should an entry door be opened. ON for perimeter arming and ALL SYSTEM ON for perimeter and interior arming. www.PDF-Zoo.com XRSuper6 Arming and Disarming...
2. The keypad then displays any zones that went into alarm or any communication problems that occurred during the armed period. 3. The keypad next displays ALL SYSTEM OFF to confirm the system is disarmed. www.PDF-Zoo.com XRSuper6 Arming and Disarming...
AWAY or HOME SLEEP AWAY (you may have three areas). 2. Select HOME to arm the Perimeter only. Select SLEEP to arm the Perimeter and Interior. Select AWAY to arm the Perimeter, Interior, and Bedroom. www.PDF-Zoo.com XRSuper6 Arming and Disarming...
BEFORE deciding to disarm the system. If you do not want to disarm the system and send the abort report, press SILENCE to only turn off the alarm bells. www.PDF-Zoo.com XRSuper6 Arming and Disarming...
The following pages detail each User Menu item and provide during an alarm. instructions on when and how to use them properly. OUTPUTS ON/OFF Turn on or off any of the outputs described in the System Setup section of this guide. XRSuper6 User Menu...
Activity Check Disabled message to the central station. 3. When YES is selected, the keypad displays CHECK ENABLED for four seconds and then sends the Activity Check Enabled message to the central station. www.PDF-Zoo.com XRSuper6 User Menu...
This also activates the door strike if your system has an Easy To exit the Output menu option, press the Back Arrow key until Entry™ access control keypad. you have returned to the keypad's Status List. www.PDF-Zoo.com XRSuper6 User Menu...
4. To reset a zone, enter the zone number and press the Select key under RST. 5. To Bypass a zone, enter the zone number and press the Select key under BYPS. www.PDF-Zoo.com XRSuper6 User Menu...
Testing your system's burglary protection: The System Test function should be part of your weekly testing and should be followed by placing the interior and perimeter burglary devices in Zone Monitor mode. See Zone Monitor. www.PDF-Zoo.com XRSuper6 User Menu...
6. Enter a 4-digit user code and press COMMAND. This is the number the user will use each time they arm, disarm, or make changes to the system. www.PDF-Zoo.com XRSuper6 User Menu...
Refer to the System Setup section of this guide to see if your system is programmed for Ambush. If so, do NOT program a code for user number 1 if you intend to use the Ambush function. www.PDF-Zoo.com XRSuper6 User Menu...
DAY: - Enter up to two digits for the day. Press COMMAND. YEAR: - Enter up to two digits for the year. Press COMMAND. The display returns to TIME DAY DATE. Press the Back Arrow key to exit the User Menu. www.PDF-Zoo.com XRSuper6 User Menu...
If you select FIRST, use the COMMAND key to scroll up through the events displays. If you select LAST, use the Back Arrow key to scroll down through the event displays. www.PDF-Zoo.com XRSuper6 User Menu...
Event Types - There are 7 event types you may see here: ALR - Alarm TBL - Trouble RST - Restore LOW - Low battery MIS - Missing xmitter FLT - Zone Fault SVC - Service Smoke Detector Note: LOW and MIS are for wireless systems only. www.PDF-Zoo.com XRSuper6 User Menu...
Check-in time. AUTO RECALL Central station at the date and time 32-Character Display Description shown. MSG 3: 31P 10 / 17 User 16 selected the Check-in feature CHECKIN USER: 16 at 3:31 PM on Oct. 17. www.PDF-Zoo.com XRSuper6 User Menu...
System Monitor Event Names - There are 2 system monitors: system, you must contact our service department directly for assistance. AC POWER BATTERY Note: This feature is not displayed if it has not been enabled on your system. www.PDF-Zoo.com XRSuper6 User Menu...
My system sends Zone Bypass reports. _______________________________________________ _______________________________________________ My system sends Ambush reports. _______________________________________________ Enter the Output number above when using the Outputs On Off My system sends Abort reports. User Menu option to manually toggle the outputs. www.PDF-Zoo.com XRSuper6 System Setup...
Temp Code - Is this code set to expire after seven days? Arm Only - Is this user restricted to just arming? Refer to the User Codes section of this User's Guide for additional information. Circle Your Selections www.PDF-Zoo.com XRSuper6 System Setup...
Strike relay activates. See Door Strike Relay Operation above. before the zone 2 Soft- Shunt expires. Home/Away systems only activate the Door Strike relay when While the keypad is in the Status List, present arming and disarming. your access card. www.PDF-Zoo.com XRSuper6 Appendix...
Using the access reader for user menu access You can also use a card reader to access the User Menu when the The system disarms the areas and activates the Door Strike relay. See Arming and Disarming. MENU? NO YES display is shown. www.PDF-Zoo.com XRSuper6 Appendix...
FA113 User's Guide These instructions guide you through the operation of the XRSuper6 Command Processor system using the FA113 Wireless Keychain Remote. The FA113 uses the audible output capability of the Security Command keypad to sound confirmation tones. It is recommended that you use the FA113 within hearing distance of these keypads.
If this message is for areas that are being armed or disarmed, the area numbers are shown in sequential order. For example, 1 2 4. User Number This is a 3-digit number, that identifies the user. Security Command Numeric Paging www.PDF-Zoo.com XRSuper6 Appendix...
PhoneAccess™ User's Guide This exciting feature allows you to call your XRSuper6 system from any outside touch-tone phone to arm and disarm protection areas Quick Reference Wallet Card or turn on or off the panel's relay outputs. How it works PhoneAccess™...
895 Voice Module 1. Call the panel phone number. The panel answers and sounds You can also use the 895 Voice Module with the XRSuper6 one short tone. Command Processor™ panel. The 895 allows you to call your 2. Enter your code within 8 seconds. One beep means the code security system using a touch-tone telephone, and perform a is good.
The wireless receiver is not communicating Wireless Trouble Call your service person. with the 472 Inovonics 900MHz Interface. Non-Polled Address Keypad Keypad is set to an invalid address. Call your service person. Only www.PDF-Zoo.com XRSuper6 Appendix...
List 24 Zone 20 Zone Activity Check 19 Resetting Sensors 13 Zone Bypass 20 COMMAND key 4 Zone 2 Exit Error 3 Activity Check 12, 19 Events 20 Monitor 14. See also Monitoring Zones (LED) Status 3 www.PDF-Zoo.com XRSuper6 Appendix...