Page 2
Always respect the following implicitly: The operation of kitchens and kitchen exhaust air equipment must only be performed with FRANKE - aerosol filters, see Figure 2a, page 5 inserted in the fume extraction hood. The UVC system must be switched off before the filters are removed from the...
Page 3
UVC-System Instruction manual Functional principle Whenever any cooking or frying is done, organic matter is deposited in the exhaust air systems. The highly efficient and effective UVC lamps "F" Cleaned exhaust air (see Fig. 1. Page 4) in our UVC system see to it towards the outside that this fat-contaminated kitchen air is processed without any problems.
Page 4
Fig. 1 Operating panel mesh filter main switch Airflow filter buzzer cover on-off button aerosol filter (Franke filter) front flap control UVC lamp socket for UVC lamp hinge with safety switch H1 screw head (safety switch) locks for front flap...
Page 5
14:151 geprüfte Sicherheit geprüfte Sicherheit Operating panel locks for front flap main switch screws for control component buzzer aerosol filter (Franke filter) on-off button front flap control hinge with safety switch H1 screw head (safety switch) FIG 2a FIG 2b...
Therefore, it is a basic principle that the UVC Clean the UVC system according to Chapter system must be shut down in all cases before the Franke aerosol filters of the universal hood or the mesh filters "M" are The failure to respect these specifications removed from the UVC system.
Page 7
Obligatory instructions: The operation of kitchens and kitchen exhaust air equipment must only be performed with Franke aerosol filters inserted in the universal hood. The UVC system must be switched off before the filters are removed from the hood! 2. Installation The installation must be performed by technical personnel in accordance with the manufacturer's specifications;...
Page 8
4.1 Operating information Obligatory instructions: The operation of kitchens and kitchen exhaust air equipment must only be performed with aerosol filters of the Franke SKKG, SKKF, SKKB filter type inserted in the universal hood. The UVC system must be switched off before the filters are removed from the hood.
Page 9
"ON-OFF" button. In the setup menu, you can set the method you have decided; see Chapter 4.3, page 10. Check that all of the Franke aerosol filters are present in the hood and correctly locked in place.
Page 10
UVC-System Instruction manual 2 Control a. Control elements UVC-System UVC-System UVC-System Franke Foodservice On-off switch Systems GmbH RUNNING 15.01.2004 2345,02 h 14:15:12 Up key Setup Down key Confirm key Function keys geprüfte Sicherheit Functions In the setup menu, which is accessed by pressing the "SETUP" key, "0000"...
Page 11
UVC-System Instruction manual Set language Automatic ON Bring up the setup menu, enter the password, Monday press F1, and the following menu appears: Hour Minute Select language English Automatic OFF Change with key Monday Back forward Hour Minute The desired language can be set with the keys F1 or F4.
Page 12
UVC-System Instruction manual Press F1 and hold it down. You can now set Display contrast the first digit with the "up" and "down" keys. The contrast of the display can be adjusted to By the same principle, the remaining 3 digits unfavourable lighting conditions.
UVC-System Instruction manual 5. Cleaning and maintenance UVC systems are designed so that trouble-free operation of the equipment is reliably ensured over its entire service life. As is also the case for other equipment, this naturally also requires a certain minimum effort in terms of appropriate inspection, maintenance and care activities.
Page 15
Ensure that only qualified technical personnel perform the necessary repairs. Ensure that only the authorized customer service perform repair work. In the event of operating faults, contact your nearest Franke service centre. When reporting to our service centre, always indicate the article number and type. This information can be found on the identification plate.
Page 16
UVC-System Instruction manual Press the "ON-OFF" key. The display now reads "Off" or "Ready". Open all of the locks with the key. Pull the latch of the front flap downwards. Pull out the mesh filter by ist handles. The filters may be rinsed in the dishwasher or with a spray nozzle and hot water.
Page 17
UVC-System Instruction manual Spray the protective tubes with plenty of glass cleaning fluid. Rub the protective tubes with a paper towel Glas Reiniger (serviette) until they are dry. glass cleaner Use a clean paper towel for each tube. If fatty residues are still visible on the paper towel after cleaning, you must repeat the cleaning.
Page 18
UVC-System Instruction manual 6. Disposal of the UVC lamps: UVC lamps have reached the end of their service life after an operating time of approx. 8,000 hours. In this case, they must be replaced with new UVC lamps. The same applies to defective UVC lamps. The replaced lamps must be returned collectively to the manufacturer in the delivery container.
Page 19
UVC-System Instruction manual Display messages Problem Problem elimination Maintenance required. The UV lamps have reached the end of Inform your service centre. their service life. Display is dark. Faulty safety fuse. Inform your service centre. Cleaning required. Cleaning is required. Clean the equipment according to Chapter Start the device.
Page 20
UVC-26/ 43/ 64 UVC - System Ersatzteilliste / spare parts 725.107.677 725.107.699 725.107.665 725.107.697 Art.Nr. Art.Nr. Art.Nr. Art.Nr. Housing 365.214 365.214 365.214 365.214 throttle control spring 365.215 365.215 365.215 365.215 holder for throttle control spring 366.264 366.264 366.264 366.264 Gasket 725.107.062 725.107.062 725.107.062 725.107.062...
Page 21
UVC - System Ersatzteilliste / spare parts...
Page 23
UVC - System Elektroschaltpläne / Electricial circuit diagrams...
Page 24
Dati ed illustrazioni non sono vincolanti. Nos reservamos los derechos de introducir modificaciones en el diseno, equipamiento y de hacer erros. Los datos y las figuras pueden ser variadas sin previo aviso. Franke Foodservice Systems GmbH Franke CG Franke CG...
Need help?
Do you have a question about the uvc-26 and is the answer not in the manual?
Questions and answers