Vermont Castings SB38 Nstallation, Operation And Maintenance Manual page 12

Woodburning fireplace
Table of Contents

Advertisement

SB38 / SB44 Series Woodburning Fireplace
Single Story installation with attic Space
Chimney Cap
Storm Collar
Flashing
18' Min. 
17"
Square
Opening
in Joist
Figure 10
FP1881 
single story install 
8/08 
Figure 11
FP1882
chimney location
8/08
1
Flue Outlet Height
3' Min. or ' Above
any Point within 10'
Attic Space
See Table
1 for Roof
Opening Size
Firestop Spacer
(" Air space
Clearance to
Combustibles)
Chimney
Sections
" Minimum Clear-
ance to Combus-
tibles
FP1881
Preferred Location
FP188
iNSulatiNg fireplace eNcloSure for
cold climateS
if you live in a cold climate, it is not required but highly
recommended that you insulate the fireplace enclosure to
eliminate cold air penetration as much as possible.
Insulate base of fireplace with a noncombustible insulation
rated for a minimum of 300° F. Insulating is very important
for outside wall installations over a concrete slab. If fire-
place is installed on a platform, insulation should be placed
on top of the platform before fireplace is set. Figure 9
When a fireplace is installed in a chase or on an outside
wall, enclosure should be treated like any outside wall in
a home. Insulation should be installed on the inside wall
as well as the outside wall(s). In a chase, it is also a good
idea to install a firestop at the first ceiling level above the
fireplace and enclose the chase with sheeting material.
Insulation may then be installed above sheeting material to
assure the space around the fireplace is totally protected.
Figure 9
cautioN: wheN iNStalliNg a fireplace iN aN
iNSulated eNcloSure, be Sure all required
air SpaceS are maiNtaiNed. Figures 10 & 12
Chimney Cap
Storm Collar
(Included with cap)
Poor Location
max.
installation
height -
86 ft.
17" Square
Opening in Joist
Figure 12
iNStallatioN preparatioN
multiple Story installation
Flue Outlet Height
Flashing
See Table 1 for
Roof Opening
Size
17" Square
Opening in
Joist
17" Square
Opening in
Joist
FP1883 
multistory install 
3 ft. Min. 
Attic Space
Firestop
Spacer ("
Air Space
Third Floor
Clearance to
Combustibles)
Area
" Clearance to
Combustibles (Min.)
Second
Firestop
Spacer
Floor Area
Firestop
Spacer
First Floor
Area
FP1883
87D0057