Test For Leaks - GE GTD18GSSJWW Installation Instructions Manual

Hide thumbs Also See for GTD18GSSJWW:
Table of Contents

Advertisement

Available languages

Available languages

CONNECTING A GAS DRYER (skip for electric dryers) (cont.)

TEST FOR LEAKS

Never use an open flame to test for gas leaks.
Check all connections for leaks with soapy solution
or equivalent.
Apply a soap solution. The leak test solution must
not contain ammonia, which could cause damage
to the brass fittings.
If leaks are found, close the valve, retighten the
joint and repeat the soap test.
Open Gas
Valve
ELECTRICAL CONNECTION
INFORMATION FOR GAS DRYERS
WARNING
Plug into a grounded 3 prong outlet.
DO NOT remove ground prong.
DO NOT use an adapter.
DO NOT use an extension cord.
Failure to do so can result in death, fire or electrical
shock.
Installation Instructions
- Electrical Shock Hazard
ELECTRICAL CONNECTION
INFORMATION FOR GAS DRYERS (cont.)
The dryer must be electrically grounded in
accordance with local codes, or in the absence of
local codes, with the National Electrical Code, ANSI/
NFPA 70 or Canadian Electrical Code, CSA C22.1
This appliance must be supplied with 120V, 60Hz,
and be connected to a properly grounded branch
circuit protected by a 15 or 20 amp circuit breaker
or time delay fuse. If electrical supply provided
does not meet these requirements, it is the owner's
responsibility to have a licensed electrician install a
properly grounded 3-prong outlet.
Ensure proper
ground exists
before use.
If local codes permit an external ground wire
(not provided) may be added by attaching to the
green ground screw on the rear of the dryer, and
to a grounded metal cold water pipe or other
established ground.
Ground
Screw
8

Advertisement

Table of Contents
loading

Table of Contents