Snmp; Tacacs+ Radius Servers - Datatek IP-DSU User Manual

Internet protocol-data service unit
Table of Contents

Advertisement

The
reboot
command restarts the unit. The command has no arguments, but is
confirmed by password. A reboot should be performed after a software upgrade, and
prior to software registration.

4.11 SNMP

Syntax: snmp [ipaddr=<Trap Mgr Addr>] [port=<Trap Mgr Port>]
The
snmp
command is used to configure the IP address of the SNMP trap manager.
Since traps are unsolicited alarms, an agent can take the initiative to inform the manager
of the occurrence of a predefined condition. Typical conditions include the cold-start or
warm-start of equipment and a link-down or link-up condition.
A single or multiple SNMP managers can access the IP-DSU. However, only one SNMP
manager can be predefined as the trap manager. By administering this command, all
traps will be directed to the chosen trap manager. The port number should be configured
for 162 on new configurations, which is standard practice.

4.12 TACACS+ RADIUS Servers

Syntax: tac < PRI | SEC > [ ipaddr=<IP Address> ]
The
tacplus
command is only visible when the unit is logged in. The tac command
allows the configuration of up to two TACACS+ RADIUS servers for the device. the
servers are used as a primary server and a secondary server, although they may be
individually disabled.
The
< PRI | SEC >
syntax specifies which server is to be configured. A server may not
be configured while enabled
The
[ ipaddr=<IP Address> ]
The
[ port=<TCP Port> ]
server. The TACACS+ service defaults to TCP port 49, but any port may be specified.
The
[ key="Encryption Key" | NONE ]
Encryption key must be enclosed in double quotes, and the double quotes are not part of
the key. If no encryption is desired, the value of
service.
The
ENABLE
command allows this server to be used for service, and prevents further
configuration.
The
DISABLE
command prevents this server from being used for service, and
subsequently allows configuration.
02/02/08
I P - D S U U s e r ' s M a n u a l
[ port=<TCP Port> ]
[ key="Encryption Key" | NONE ]
[ ENABLE ]
[ DISABLE ]
specifies the IP address of the configured server.
specifies the TCP port to use when communicating with the
specifies an encryption key to use. The
NONE
is used to designate unencrypted
26