CONTENTS Getting Started ............2 Setup Procedures ............3 Setup Flow Chart ............4 Group 0 : Interface Selection........ 5 Group 1 : Device Selection for keyboard Interface..........6-7 Group 2 Intercharacter Delay......8 Group 3 : Language for Keyboard Interface... 9-10 Group 4 : Terminator........11-12 Group 5 : Scan Mode........13-14...
Getting Started Installing Keyboard Wedge Scanner To install a keyboard wedge scanner, follow the steps listed below: 1) Make sure that the scanner has the correct cable for the system (a PC or terminal) 2) Turn off the power of the system 3) Unplug the keyboard from the system 4) Connect the cable to the system and keyboard...
Setup Procedures 1) Locate a group that contains the parameters to be changed. 2) Scan the "Enter Group #" label. The scanner will sound beeps indicate that setup is in progress 3) Scan the label representing the parameter to be changed 4) Scan the "Exit"...
Setup Flow Chart ENTER GROUP SELECT ITEMS EXIT Set All Defaults Show Version Note: (*) denotes default setting. Options marked by ( ) only available upon request.
Group 0: Interface Selection ENTER GROUP EXIT KEYBOARD RS-232 (OCIA) (DTMF) Reserved 2 Resered 3 Reserved 4 Note: The interface is pre-set at factory according to the model of the device.
Group 1: Device Selection for Keyboard Interface ENTER GROUP EXIT PC/AT, PS/2 50,60,70,80(*) PC/XT PS/2 25, 30 (NEC 9801) (IBM 5550) (PS 55) (NEC N5520) (ACER 7300) (KW105D/ CT-700A/W ANG 5120) (WANG 5425) (MAC_SE) (LC-6533) Note: Options marked by ( ) are only available upon request.
Group 1: Device Selection for Keyboard Interface ENTER GROUP EXIT (IBM3196, 3197, 3476, 3477) Reserved Q Reserved R Reserved T IBM3197 IBM 3476 IBM3477 Reserved Reserved 6 Reserved Reserved 8 Reserved...
Group 3: Language for Keyboard Interface ENTER GROUP EXIT U.S. (*) ENGLAND FRANCE GERMANY ITALY BELGIUM SWEDEN/FINLAND SPANISH DENMARK PORTUGAL SWISS NORWAY...
Group 3: Language for Keyboard Interface ENTER GROUP EXIT CANADA HOLLAND POLAND LATIN JAPAN Reserved Reserved Reserved (IBM THINK-PAD FOR JAPAN) (PANASONIC CF- FOR JAPAN) Note: Options marked by ( ) are only available upon request.
Group 5: Scan Mode ENTER GROUP EXIT 1: Trigger On/Off 2: Trigger On/ Good Read Off (*) 3: Trigger On/ Good Read Off/ Delay Timeout = ? 4: Continuous/ Trigger Off 5: Continuous/ LED Always on 6: Continuous/ No Trigger 7: Continuous/ Testing Setting:...
Group 6: Preamble and Postamble ENTER GROUP EXIT Preamble Postamble Preamble & Postamble Setting: Scan Enter Group 6 Label --> Scan Preamble or Postamble Label --> Refer to ASCII T able (Page 44), scan two digits in Table-Hex representing one character, maximum 10 characters (Page 43) can be accepted-->...
Group 11: CODE 11 ENTER GROUP EXIT Disable Enable (*) Number of Check Character Two (*) Transmit Check Character Disable Enable (*) Enable/Disable Checkdigit Disable Enable (*)
Group 14: CODABAR / NW7 ENTER GROUP EXIT Enable (*) Disable Transmit Start/End Character Disable (*) Enable Start/End Transmit Type ABCD/TN*E ABCD/ABCD abcd/tn*e abcd/abcd (*)
Group 16-3: EAN-8/JAN-8 ENTER GROUP EXIT Enable (*) Disable ADD-ON 2/5 Disable (*) Enable Transmit Check Character Disable Enable (*) Truncate Leading Digit Disable (*) Enable EAN-8 Convert to EAN-13 Disable (*) Enable 1 (add zeros in the front of barcode) Enable 2 (add zeros in the middle of barcode)
Group : General Parameters ENTER GROUP EXIT Upper Case Lower Case (*) Universal ALT Mode Buzzer Pitch (Default : 21) Buzzer Duration (Default: AA) Buzzer Pitch & Buzzer Duration Setting: Scan Enter Group 18 Label --> Scan Buzzer Pitch or Buzzer Duration Label --> Scan Two Digit Labels in T able-Hex (Page 43)-->...
Group : Code ID Setting ENTER GROUP EXIT CODE 39/CODE 32 INTERLEAVED 2 OF 5 INDUSTRIAL 2 OF 5 MATRIX 2 OF 5 CHINA POSTAGE CODE 128 CODE 93 CODE 11 MSI/PLESSEY CODABAR/NW7 EAN-13 EAN-8 UPC-E UPC-A CODE 4 Note: Refer to ASCII T able (Page 44), scan two hexadecimal lables in Table Hex (Page 43) to represent one character.
Group unction Key Emulatio ENTER GROUP EXIT Enable Enable Function Key Emulation: Scan Enter Group 21 Label --> Scan Enable Label --> Disable (*) Scan Exit Label To concatenate a function key with input data, please refer to Function Key Table for its hexadecimal representation. For Example: Preamble data with F1 Scan Enter Group 6 Label -->...
Page 42
Function Code for PC XT/AT F1 ($A) F7 ($G) F2 ($B) F8 ($H) F3 ($C) F9 ($I) F4 ($D) F10 ($J) F5 ($E) F11 ($K) F6 ($F) F12 ($L)
Function Code for PC XT/AT Enter ($M) End ($U) ($B) Tab ($N) PgUp ($V) BS ($O) PgDn ($W) Up ($P) Ins ($X) Down ($Q) Del ($Y) Left ($R) Esc (%A) Right ($S) Home ($T)
PIN ASSIGNMENTS 10 Pin Modular Plug RJ-45 Male RS-232 KB USB 10P10C PWR-CTL GOOD- DAT A READ PC-CLK DATA PC-CLK SW-DET KB-CLK KB-DAT S.O.S 10P10C...
Page 48
PIN ASSIGNMENTS RS-232 Signal Output Function DB9F+DC (or without DC) VCC+5V 9 Note : For PC applications, a cable with DC power jack is required to accept external power input. DB9F+DC -Jack Inner (+)
Page 49
Keyboard Signal Output Funcion Din5F Din5M Mini-Din6M Mini-Din6F PC_Data PC_CLK Vcc+5V KB_CLK KB_Data MD6M DIN5M DIN5F MD6F USB Signal Output FUNCTION USB-A USB PLUG...