Summary of Contents for Me smooth C420506

  • Page 1 user guide guía del usuario manuel de l’utilisateur...
  • Page 2: Table Of Contents

    ___________________________________________________2 getting to know your me system ________________________________4 who should not use me /contraindications ______________________6 warnings_______________________________________________________6 setting me up __________________________________________________9 skin sensitivity test ______________________________________________9 how to use me _________________________________________________10 treating your body __________________________________________11 treating your face ___________________________________________12...
  • Page 3: Introduction

    Congratulations on your new me ˉ smooth elo ˉ s professional hair removal system! me ˉ is the only at-home hair removal device to use patented elo ˉ s technology that is clinically proven to be safe and effective for all skin tones.
  • Page 4 ˉ is intended for use on ALL skin tones (the skin color you were born with). light fair medium...
  • Page 5: Getting To Know Your Me System

    getting to know your system device components • base unit (1) • cradle (2) • control panel (3) with: • power button • error warning button • elo ˉ s energy setting buttons (Low, Medium, High) • cartridge life indicator (100%, 50%, Empty) •...
  • Page 6 applicator components • light output window (6) • silver RF contact bars (7) • cartridge: comes attached to the applicator and is preloaded with pulses (8) • activation button (9) • cooling outlet (10) • accessory protective cap (not to be removed unless attaching an official accessory) (11) applicator top view applicator bottom view...
  • Page 7: Who Should Not Use Me /Contraindications

    KEEP OUT OF REACH OF CHILDREN. The me ˉ should not be used by anyone or on anyone under the age of 18. The use of the me ˉ on or by children has not been studied and could result in serious injury.
  • Page 8 DO NOT use on or around the eyes, eyebrows or eyelashes. Doing so can cause permanent eye injury. DO NOT use on a man's face, jaw or neck. Using the me ˉ in these areas may result in skin injury.
  • Page 9 Doing so may generate too much heat which can injure the skin. DO NOT use me ˉ if you experience redness on your skin and it persists for more than 24 hours after treatment. Contact your doctor or Customer Service.
  • Page 10: Setting Me Up

    setting 1. Connect the power cord into the back of the base unit. 2. Connect the power cord to an electrical outlet. Make sure that the applicator is placed inside its cradle. 3. Press the power button to turn the system on. Wait until the indicator next to the power button turns green.
  • Page 11: How To Use Me

    • To prepare for your me treatment, first shave the area that you want to treat. Wipe clean and dry the area. This will ensure that the elo ˉ s energy is focused on the hair follicles beneath the surface for optimal efficacy.
  • Page 12: Treating Your Body

    treating your body Gently place the applicator on your skin, so that the two • silver RF contact bars are in complete contact with the skin. The applicator will emit pulses of bright white light - this is the elo ˉ s energy at work. The applicator will not work unless both silver RF contact bars are touching your skin (3).
  • Page 13: Treating Your Face

    treating your face Gently place the applicator on your skin, so that the two silver • RF contact bars are in complete contact with the skin. The applicator will emit pulses of bright white light - this is the elo ˉs energy at work.
  • Page 14: What To Expect

    For best results, treat the target area once a week for 7 weeks. Use your temporary hair removal solution in between treatments as you normally would. After your initial protocol, use your me ˉ for touch ups of new hair growth as needed.
  • Page 15: How To Replace Your Cartridge

    • Make sure that the me system is turned off and the cable is unplugged from the electrical wall outlet (1). Remove the used cartridge from the applicator by holding the •...
  • Page 16: Disposal/Recycling

    You will need to use an adaptor for the plug, since electrical wall outlets vary by country. Make sure the me system does not get wet while traveling and do not use it in a wet environment.
  • Page 17: Troubleshooting

    troubleshooting Indicator What does it mean How to react Device No lights are on Power cable is not connected Connect power cable energy setting energy level was Select an level. buttons on the base selected are blinking (High-Medium-Low) activation button energy level was selected Press the activation button.
  • Page 18 “Empty” indicator is No more pulses remaining in Insert a new cartridge constantly on cartridge If you still have questions about your me system, contact Customer Service at www.mepower.com/contactus or call us toll free at 1-877-651-1177.
  • Page 19: Warranty

    warranty Note: if your device is under warranty with your local distributor it will prevail over the below warranty terms. Your mē device is warranted to be free from defect in material and workmanship for a period of one year (or otherwise stated by your local distributor) from the original purchaser date under normal use.
  • Page 20 THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY DEPENDING ON YOUR STATE, PROVINCE OR OTHER JURISDICTION. SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU.
  • Page 21: Manufacturer Information

    The nameplate label is adhered to the bottom of your me system. It displays the manufacturer’s name & address, the system’s part & LOT numbers, electrical and regulatory standards with which the me ˉ system is designed to comply.
  • Page 22: Specifications

    specifications Light spectrum: 550 – 1200 nm • • RF Wave frequency: 6.78 MHz • Max Radiofrequency power: 5 Watts Pulse Light repetition rate: up to 1.1 Hz (1 pulse every 0.9 seconds). • • Applicable Standards: Safety Standards • EN 60335:1 2002(A1:2004;...
  • Page 23 acceptable environmental conditions Storage and transportation Temperature 14ºF- 131ºF (-10ºC - 55ºC ) Humidity 90% at 131ºF (55ºC) Pressure 700 -1060hPa Operation: Temperature 50F- 86ºF (10ºC - 30ºC) Relative Humidity up to 80% at 99ºF (37ºC) up to 13,000 ft (3900 m) Altitude...
  • Page 24 , and are trademarks of Syneron Medical Ltd. elo - s me is a trademark of Syneron Beauty Ltd. and may be registered in certain jurisdictions. and may be registered in certain jurisdictions. (electro-optical synergy) is a proprietary technology of Syneron Medical.