Main CBA Top View
BECAUSE A HOT CHASSIS GROUND IS PRESENT IN THE POWER
SUPPLY CIRCUIT , AN ISOLATION TRANSFORMER MUST BE USED.
ALSO , IN ORDER TO HAVE THE ABILITY TO INCREASE THE INPUT
SLOWLY , WHEN TROUBLESHOOTING THIS TYPE POWER SUPPLY
CIRCUIT , A VARIABLE ISOLATION TRANSFORMER IS REQUIRED.
WF1
TP751
V-OUT
TP506
END-S
WF2
TP502
RF-SW
VR501
SW-P
1-10-79
CAUTION
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,
REPLACE ONLY WITH THE SAME TYPE FUSE.
Sensor CBA Top View
BHB300F01011-B
CAUTION !
Fixed voltage (or Auto voltage selectable ) power supply circuit is used in this unit.
If Main Fuse (F001) is blown, check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
BHB300F01011-A
1-10-80
NOTE :
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
TP507
S-INH
TP501
CTL
WF5
TP301
C-PB
1-10-81
BHC400F01017-A