Index Compliance Information Compatibility with World Electrical Systems Electromagnetic Emissions Safety Instructions and Precautions Product Overview Description of Operation Calibration Equipment Setup Operation Cleaning the Fogger Maintenance Circuit diagram Specifications Warranty Compliance Information Modifications of the 7505 Vectra-Jet fogger are available to comply with the following safety standards: UL-73 (Ninth Ed.) CSA 22.2 No 0:2001, 22.2 No 68-92:2004...
IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS RELATING TO RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS WARNING – When using electric appliances, follow these basic safety precautions: Read all the instructions before using the appliance. To reduce the risk of injury, close supervision is necessary when an appliance is used near children.
Page 4
GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug.
Safety PrecautionS Do not inhale fog output. Highly atomized liquid droplets can float in the air a long time and are quickly absorbed by the lungs. Depending on the material being fogged, this could result in serious injury or death. Do not use to apply any liquid that is hazardous to people, animals or property when atomized into small droplets.
Product overview The Vectra-Jet™ 7505 fogger atomizes light liquids into a fog, mist or spray of small droplets. It can atomize both oil- and water-based solu- tions, as well as emulsions and dilute suspensions of wettable powders. Typical uses of this machine include: • Cleaning, sanitizing and disinfecting (applying germicides or sanitizing chemicals) • Control of mold and mildew (applying sporicides, fungicides or...
Description of operation Fogmaster foggers atomize liquids into small droplets (fog or mist) by shearing them in a highly turbulent section of the nozzle. A blower in the power head supplies air to create the turbulence. The liquid flow into the nozzle, regulated by the control valve, determines average fog droplet size.
equipment Setup Attach Air Filter The air intake filter and cover are packed in the top of the carton. Place the filter cartridge over the bracket at the rear of the power head and hold it against the rear housing. Screw filter cover into the bracket and tighten snugly.
operation Add chemical solution to the liquid tank. If applying a wettable powder or suspension, remove retaining ring and screen from weighted suction tube weight. Clamp the power head in place. Using the measured flow rate and the dosage instructions provided by the chemical label or chemical manufacturer, calculate the time required to properly fog the area.
Maintenance The major components of the fogger are identified on page 6. A detailed parts list and order form is included as a separate sheet with each unit. This document is also available for download on our web site. WARNING: Unplug fogger power cord from electrical outlet before attempting any maintenance operation.
Page 11
About motor brushes Two graphite brushes convey electric power to the motor commuta- tor. Brushes are a consumable item, and have a lifetime of about 650 operating hours. Operating without the air intake filter lets airborne dirt and moisture enter the motor; this can reduce brush life substantially. When brushes are worn the motor does not operate properly.
If the power cord is damaged, it must be replaced with an approved cord that includes a continuous line to ground (earth). Return unit to Fogmaster or authorized importing distributor for service. WARNING: A continuous ground (earth) line in the power cord is essential for safe operation.
Page 13
POWER HEAD HOUSING GROUND RIVET GREEN GROUND RIVET EMI FILTER (CE models) BLACK BLACK WHITE WHITE 100-120V~ MODELS 100-120V~ MODELS CORD/PLUG WITH EARTH STANDARD UNIT CE VERSION 100-120VAC 50/60 Hz POWER HEAD HOUSING GREEN GROUND GROUND RIVET RIVET EMI FILTER (CE models) BROWN BROWN...
Specifications for 7505 Vectra-Jet fogger Nozzle Technology Counter-rotating vortex design. High turbulence in nozzle shears feed liquid into fog-sized droplets. Nozzle has no small orifices and is resistant to plugging. Chemicals Nozzle can atomize both oil-based and water-based liquids. Particle size distribution varies with liquid viscosity, surface tension, density and flow rate.
This product is warranted for one year from the purchase date against defects in materials and workmanship. If you have a warranty claim, return the unit freight prepaid to The Fogmaster Corporation. We will repair or replace (at our option) the unit and return it to you.
Page 16
In the interest of improving internal design, operational function, and/or reliability, The Fogmaster Corporation reserves the right to make changes to the products described in this document without notice. The Fogmaster Corporation does not assume any liability that may occur due to the use or application of the product described herein.
Need help?
Do you have a question about the VECTRA-JET 750510CE and is the answer not in the manual?