Butterfly Energy Systems BESM-24AO23 Installation Manual

Air intelligence series

Advertisement

Quick Links

Bu erfly Energy Systems
Air Intelligence Series
Installa on Guide
(For Outdoor Mul -Head Systems)
BESM-24AO23
Thank you for choosing Bu erfly Energy Systems, please review installa on guide
before installa on and retain for future reference.

Advertisement

Table of Contents
loading

Summary of Contents for Butterfly Energy Systems BESM-24AO23

  • Page 1 Bu erfly Energy Systems Air Intelligence Series Installa on Guide (For Outdoor Mul -Head Systems) BESM-24AO23 Thank you for choosing Bu erfly Energy Systems, please review installa on guide before installa on and retain for future reference.
  • Page 3: Table Of Contents

    In line with the company’s policy of continual product improvement, the aesthetic and dimensional characteristics, technical data and accessories of this appliance may be changed without notice. GENERA L INFORMATION CONTENTS Conformity And Range The Instructions Before Use Name of Parts Technical Data Outdoor Unit Working Temperature Range Electrical Connections...
  • Page 4: The Instructions Before Use

    IMPORTANT REMINDERS GENERA L INFORMATION Basic precautions should be taken to reduce the risk of injury to person, fire or electrical shock when operating an electrical appliance including the following: 1.Read all instructions before using the appliance. 2.This appliance is hot when in use. To avoid burns,do not touch bare skin on hot surfaces.
  • Page 5: Name Of Parts

    GENERAL INFORMATION NAME OF PARTS BESM-24AO23 Warning If the supply cable is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. Be sure to cut off the power supply before cleaning the air conditioner;...
  • Page 6: Technical Data

    GENERA L INFORMATION TECHNICAL DATA BESM-24AO23 MODE Electrical data Electricity supply 208/230V/1~60Hz Fuse or air switch Minimum power cable section Refrigerant gas(R410A) 2200 Size and clearance GENERA L INFORMATION OUTDOOR UNIT WORKING TEMPERATURE RANGE Outdoor side DB/WB( Maximum cooling 48/-...
  • Page 7: Electrical Connections

    ELECTRICAL CONNECTIONS INS TALLER BESM-24AO23 1. Remove the handle at the right side plate of the outdoor unit (ten screw). Remove the cable clamp, connect the connection cable and power cable with the terminal at the row of connection and fix the connection. The fitting line distributing must be consistent with the indoor unit terminal of line bank.
  • Page 8 HANDLING USER After having removed the packaging, check that the Handling must be done by suitably equipped qualified contents are intact and complete. technical personnel using equipment that is for suitable the weight of the appliance . The outdoor unit must always be kept upright.
  • Page 9: Installing The Outdoor Unit

    INSTALLING THE OUTDOOR UNIT INSTALLER Location Use bolts to secure the unit to a flat, solid floor. Install the drain fitting and the drain hose(for When mounting the unit on a wall or the roof, make model with heat pump only) sure the support is firmly secured so that it cannot Condensation is produced and flows from the outdoor unit move in the event of intense vibrations or a strong...
  • Page 10: Maintenance

    Contact service center before installation to avoid the malfunction due to unprofessional installation. When picking up and moving the units, you must be guided by trained and qualified person. Ensure that the recommended space is left around the appliance . BESM-24AO23 50cm or more...
  • Page 11: Check After Installation

    CHECK AFTER INSTALLATION INSTALLER Check Items Problems Owing to Improper Installation Is the installation reliable? The unit may drop, vibrate or make noises Has the gas leakage been checked? May cause unsatisfactory cooling (heating) effect Is the thermal insulation of the unit May cause condensation and water dropping sufficient? Is the drainage smooth?
  • Page 12 66129915030...

Table of Contents