Movement Detector
Introduction
• A CCTV event trigger utilising two independent passive infrared detectors combined in a
T05 package. Both sensors have to trigger before the detector signals an alarm. This high
precision very reliable presence detector has been designed for use within CCTV installations.
Programmable parameters include three normally open or normally closed configurations
for the two CCTV volt free output relays, as well as a changeover timer, a pulse count feature
and a choice of detection ranges from 25 to 50 metres.
• In addition there are two switched negative outputs. The 'A' output gives a single 400ms
trigger every time the detector activates and is generally used in conjunction with the GJD
lighting controllers to give 24-hour visual and audible alarm indication. The 'S' output is a
photocell-controlled signal giving a fixed 60-second trigger on activation.
Additionally independent front and rear tamper circuits are combined to provide a volt free
tamper alarm contact. The flexibility of the various outputs and timers allows the
equipment.
• The integral dual axis tilt sensor allows 180° of pan and 90° tilt. This increases the speed
of the outdoor installation and provides incredibly accurate aiming of the detection pattern.
The electronics module is acrylic coated for additional component stability. It is encased in
a vandal-resistant high impact zinc alloy housing with a UV stabilised translucent front cover
ensuring the sensor is impervious to and unaffected by weather conditions. Additionally the
combination of precision electronics, digital white light filter and double shielding eliminates
false alarms from the sun and other visible light sources.
The
indication of the orientation of the detector head, and totally hides the wiring.
Installation & Set Up Guide
to be used in multiple situations without the need for any further customised
design gives a neat and professional appearance with no visible
1
GJD 350

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GJD 350 and is the answer not in the manual?

Questions and answers

Summary of Contents for dtec GJD 350

  • Page 1 Movement Detector GJD 350 Installation & Set Up Guide Introduction • A CCTV event trigger utilising two independent passive infrared detectors combined in a T05 package. Both sensors have to trigger before the detector signals an alarm. This high precision very reliable presence detector has been designed for use within CCTV installations.
  • Page 2 Installation & Set Up Guide D-TECT QUICK INSTALLATION GUIDE Apply supply voltage to the unit, the blue led flashes 3 times The detector takes approximately 2-3 minutes to settle The walk test led is factory set to OFF. Pressing the programme button once will enable the walk test led for 5 minutes.
  • Page 3: Mounting The Unit

    Installation & Set Up Guide Stage 1 – Mounting the unit Optional for Tamper Cup Cable Holes fig. 1 Template During installation the electronics must be protected against water, as trapped moisture can affect or damage the unit. 1) Using the template provided drill the wall to accept the two fixing screws, the cable entry and the tamper cup (if used).
  • Page 4 Installation & Set Up Guide Stage 1 – Mounting the unit (Cont.) fig. 4 3) Feed standard 12 core alarm cable into the cable entry; bare the wires and connect to the removable terminal block as shown in fig. 7. Screw the unit to the wall ensuring that the tamper pin is correctly located and that the tamper microswitch is closed.
  • Page 5: Connecting The Unit

    Installation & Set Up Guide Stage 2 – Connecting the Unit TAMPER CONNECTION NORMALLY CLOSED TAMPER CONNECTION TAMPER CIRCUIT FRONT + REAR 0V SUPPLY TO GJD LIGHTING CONTROLLER TO GJD LIGHTING CONTROLLER 12VDC SUPPLY - A S + ALARM OUTPUT 1 ALARM OUTPUT 2 MULTIPLEXER, PTZ DOME, MULTIPLEXER, PTZ DOME,...
  • Page 7 Installation & Set Up Guide Stage3 – Beam Alignment (Cont.) fig. 9 Stage 4 – Programming The user can individually programme a number of configurable settings as illustrated in the programming chart. Factory settings are shown as shaded boxes. Changes to the existing settings can easily be made. To reset the factory settings simply remove power form the detector, press and hold the programme button (fig.
  • Page 8: Programming Chart

    Installation & Set Up Guide Stage 4 – Programming (Cont.) PROGRAMMING CHART SETTING RANGE MTRS PULSE COUNT 24HR 'S' OUTPUT LUX LEVEL CCTV 1 CONTACTS CCTV 2 TIMER SECONDS PRESS 7 TIMES TO FLASH OUT YOUR SELECTED SETTINGS. PRESS 8 TIMES TO RESET THE GJD FACTORY SETTINGS. To change any of the settings: - 1) Press the programme button as shown in fig.
  • Page 9 Installation & Set Up Guide Stage 4 – Programming (Cont.) Any alterations made to the settings are stored in the detector's non volatile memory. EXAMPLE To change the LED Setting from OFF to ON. 1) Press the programme button three times and release the button. 2) Wait until the indicator goes off.
  • Page 10 Installation & Set Up Guide Stage 6 – OPTION Definitions PULSE COUNT This is the number of times the unit has to detect on both of its sensors before signalling an output. LED MONITOR LED Off - LED disabled LED On - LED signals a detection LUX SETTING This is the approximate level that the ambient light must reach before the 'S' output will become active when there is an activation.
  • Page 11: Installation Notes

    Installation & Set Up Guide INSTALLATION NOTES...
  • Page 12 0 7 1 0 3...

Table of Contents