Technical Data - QuickTec EKCO.LN2 User Manual

Electric central heating flow boiler
Table of Contents

Advertisement

Technical data

Max. pressure
Min. pressure
Outflowing water temp.
Max. water temp.
Overall dimensions (height x
width x depth
Weight
Water connection
Expansion vessel
Safety class
Rated power
Rated voltage
Rated current
Fuse rated current
Min. connecting wires section
Max. connecting wires section
The maximum allowed network impedance
Rated power
Rated voltage
Rated current
Fuse rated current
Min. connecting wires section
Max. connecting wires section
The maximum allowed network impedance
Rated power
Rated voltage
Rated current
Fuse rated current
Min. connecting wires section
Max. connecting wires section
The maximum allowed network impedance Ω
Rated power
Rated voltage
Rated current
Fuse rated current
Min. connecting wires section
Max. connecting wires section
The maximum allowed network impedance
EKCO.LN2; EKCO.L2
EKCO.LN2..p; EKCO.L2...p
EKCO.LN2; EKCO.LN2...p
EKCO.L2; EKCO.L2...p
EKCO.LN2; EKCO.LN2...p
EKCO.L2; EKCO.L2...p
EKCO.LN2; EKCO.LN2...p
kW
4
A
17,4
A
20
mm
3x2,5
2
mm
2
0,27
kW
12
A
3x17,3
A
20
mm
2
mm
2
kW
4
6
A
18,3
27,4
A
25
32
mm
3 x 2,5 3 x 4
2
mm
3 x 16
2
0,27
0,17
kW
12
A
3x18,3
A
20
mm
2
mm
2
MPa
MPa
°C
°C
710 x 418 x 252
mm
710 x 418 x 153
kg
G 3/4" (internal thread)
l
6
8
4
230V~
26,0
34,8
3 x 5,7
32
40
3x4
3x6
5 x 16
0,17
0,15
15
18
400V 3N~
3x21,7
3x26,0
25
32
5 x 2,5
5 x 16
0,27
8
12
220V~
36,4
54,5
3x6,1
40
63
3 x 6
3 x 10
3 x 25
0,15
15
18
380V 3N~
3x22,8
3x27,4
25
32
5 x 2,5
5 x 16
0,27
0,3 (3 bar)
0,05 (0,5 bar)
20 ÷ 85
20 ÷ 60
100
~24,5
~17,2
6
IP 22
8
6
400V 3N~
3 x 8,7 3 x 11,7
16
10
5x1,5
0,27
21
24
3x30,3
3x34,6
40
5 x 4
5 x 6
0,22
0,13
8
4
6
380V 3N~
3x9,1 3x12,2
10
16
5 x 1,5
5 x 16
0,27
21
24
3x31,9
3x35,6
40
5 x 4
5 x 6
0,22
0,13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ekco.l2

Table of Contents