  • Page 1 INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE...
  • Page 2 INSTALLATION (SECTION DEDICATED TO THE INSTALLER) RULES AND REGULATIONS PRELIMINARY OPERATIONS POSITIONING THE APPLIANCE PROTECTION OF THE FLOOR SAFETY DISTANCE CONNECTIONS MOUNTING THE HANDRAIL MOUNTING THE COVER MOUNTING THE SMOKE DISCHARGE COLLAR 1.10 MOUNTING THE SMOKE VALVE 1.11 CHIMNEY OR CHIMNEY FLUE 1.12 CONNECTION OF THE APPLIANCE TO THE CHIMNEY FLUE AND EVACUATION OF COMBUSTION PRODUCTS 1.13 CHIMNEY COWL 1.14 MAKING THE CONNECTION TO THE CHIMNEY FLUE...
  • Page 3: Installation

    INSTALLATION (SECTION DEDICATED TO THE INSTALLER) RULES AND REGULATIONS · Read this manual carefully as it contains important indications and instructions concerning the installation, use, maintenance and safety of the product. · This appliance must only be installed and used in a room deemed suitable by the specific authorities and in compliance with the relevant rules and regulations.
  • Page 4: Safety Distance

    SAFETY DISTANCE · From inflammable objects and support walls in armed concrete: - A > 800 mm B > 450 mm C > 400 mm · Any inflammable objects placed above the appliance must be kept at a safe distance: at least 1.5 metres. Always take measurements from the outside surface of the appliance (fig.
  • Page 5: Mounting The Cover

    MOUNTING THE COVER The cooker is supplied with the cover dismounted; to mount it, proceed as follows: · Fix the two hinges (fig. 3 ref. A) onto the cover (fig. 3 ref. B). · Insert the ends of the hinges in the special supports already mounted on the plate (no screws needed for the fixing). ·...
  • Page 6: Chimney Cowl

    1.11 CHIMNEY OR CHIMNEY FLUE · The chimney or chimney flue must respect the following requirements: - It must seal in the exhaust fumes, be water-tight and suitably insulated and isolated in accordance with the conditions of use (UNI 9615); - It must be made in materials that can resist normal mechanical tress, heat and the action of the products of the combustion and possible condensation;...
  • Page 7 MAKING THE CONNECTION TO THE CHIMNEY FLUE 1.14 · Connect the appliance to the chimney flue of the existing chimney, making sure that the smoke outlet pipe does not take up the free space of the chimney flue (fig. 7) ·...
  • Page 8 (SECTION DEDICATED TO THE USER) IMPORTANT WARNINGS · Read this manual carefully as it contains important indication and instructions concerning the use, maintenance and safety of the product. · All parts of this manual must be read and fully understood. Failure to do so shall be considered as improper use of the appliance which is tantamount to incorrect use of the appliance.
  • Page 9: Loading The Fuel

    STARTING UP · The appliance must only be started up after the mounting operations and the connection of the smoke evacuation ducts have been completed. On a new appliance, the paintwork finish needs to be completely dried out, therefore we recommend that you carefully follow the instructions below when first using the appliance: When first using, the appliance could emit odours which might be unpleasant;...
  • Page 10 LIGHTING UP · Put a firelighter cube or a small ball of newspaper on the brazier, then on top of this, place about 0.5 kg of twigs or small split logs and 3 small logs of wood. Using the accessories supplied, open completely the primary air inlet (fig. 9 ref. A) and the smoke valve (fig. 9 ref. B), then light the paper or firelighter with a match and close the firebox door.
  • Page 11 PRIMARY AIR VALVE 2.13 The cooker is fitted with a primary air adjustment located in the lower part of the firebox (fig. 9 ref. A), and to access, open the door for loading the firewood. A fixed secondary air inlet is located in the upper part of the firebox sides and this improves the functioning with a consequent increase in efficiency and reduction in carbon monoxide emissions into the atmosphere.
  • Page 12: Cleaning And Maintenance

    CLEANING AND MAINTENANCE (SECTION DEDICATED TO THE USER) FUNDAMENTAL PRECAUTIONS · The appliance must be switched off and allowed to cool down until reaching the room temperature. · Before starting the cleaning or maintenance, remove the plug from the mains (if present) ·...
  • Page 13 - Cleaning of the exhaust gas ducts; - Check the gaskets and replace if necessary; - Check the flue. · It is advisable to arrange an annual maintenance contract with an OLIMPIA SPLENDID service centre. ACCESSORIES The following service tools are supplied with the stove: ·...
  • Page 14: Troubleshooting

    TROUBLESHOOTING In case of malfunctioning, check the following table. If, after the checks and controls suggested, the problem persists, contact the authorised technical service. DEFECT CAUSE REMEDY • The glass on the firebox door is • Draught too low < 10 Pa •...