Versitron AC300WR Technical Manual

300 watt redundant hf-20a chassis power supply/system monitor

Advertisement

Quick Links

AC300WR
300 WATT REDUNDANT
HF-20A CHASSIS
POWER SUPPLY/SYSTEM MONITOR
TECHNICAL MANUAL
October 2003
Revision A
Copyright October 2003
VERSITRON, Inc
83 Albe Drive / Suite C
Newark, DE 19702
www.versitron.com
A031032410

Advertisement

Table of Contents
loading

Summary of Contents for Versitron AC300WR

  • Page 1 AC300WR 300 WATT REDUNDANT HF-20A CHASSIS POWER SUPPLY/SYSTEM MONITOR TECHNICAL MANUAL October 2003 Revision A Copyright October 2003 VERSITRON, Inc 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com A031032410...
  • Page 2 VERSITRON, Inc. WARRANTY All VERSITRON products are warranted against defects in materials and workmanship for the lifetime of the product. We will repair or, at our option, replace parts, which during normal usage prove to be defective during the warranty period provided that: You call VERSITRON at 302-894-0699 or 800-537-2296 and obtain a Return Maintenance Authorization (RMA) Number.
  • Page 3: Table Of Contents

    INSTALLATION PROCEDURE................4 POWER REQUIREMENTS ................6 INITIAL CHECKOUT PROCEDURE..............6 SECTION 3: OPERATION INTRODUCTION ....................7 STATUS INDICATORS ..................7 SWITCHES ......................7 ALARMS ......................7 REDUNDANT POWER CONFIGURATIONS..........9 SECTION 4: THEORY OF OPERATION INTRODUCTION ....................10 SECTION 5: MAINTENANCE AND TROUBLESHOOTING INTRODUCTION ....................11 FAULT ISOLATION ..................11 www.versitron.com...
  • Page 4 LIST OF ILLUSTRATIONS FIGURE TITLE PAGE AC300WR REDUNDANT POWER SUPPLY/SYSTEM MONITOR....2 STANDARD 19" RACK INSTALLATION............4 MODEL AC300WR FRONT PANEL VIEW .............5 MODEL AC300WR REAR PANEL VIEW............5 www.versitron.com...
  • Page 5: Section 1: Description Of Equipment

    ON/OFF switch, and a respective power LED. It also has two built-in alarm circuits with separate red LED’s for low DC voltage alarm and for system alarm monitoring. In addition, Model AC300WR also has an RS485/RS422 interface at the bank panel for low DC power alarm and for system alarm remote monitoring.
  • Page 6: Main Features

    19.0" FIGURE 1. AC300WR REDUNDANT POWER SUPPLY/SYSTEM MONITOR 1.2.3 MAIN FEATURES Model AC300WR (300 Watt, Redundant Power Supply/System Monitor) has the following main features: Ø Compact 1U Rack Mountable Size (1.75" H x 19" W x 12.12" D) Ø Combined output power of 600 Watt @ 50 Amp. (max) Ø...
  • Page 7: Specifications

    0 to 70 °C Storage Temperature -20 to 85 °C Over voltage Type Latch off Efficiency 80-90% Typical Physical Dimensions 1U (1.75" H x 19" W x 12.12" D); (4.45cm x 48.26cm x 30.78cm) Weight 13.25 lb. = 6.01kg = 212oz www.versitron.com...
  • Page 8: Section 2: Installation

    DC voltage levels in an overload situation and also for monitoring the alarm associated with any circuit card installed in the HF-20A chassis, provided that the Alarm Cut Off (ACO) switch is not enabled on the front panel of Model AC300WR. Refer to figure 3 and 4 on the next page.
  • Page 9: Model Ac300Wr Front Panel View

    DF Alarm Power 1 19.0" FIGURE 3. MODEL AC300WR FRONT PANEL VIEW Warning: To avoid damage to the LEDs and Switches DO NOT place the front panel of the unit face down, and/or DO NOT press against the front panel.
  • Page 10: Power Requirements

    The Model AC300WR Redundant Power Supply/System Monitor operates with either a 115VAC or 230VAC power sources. The unit automatically recognizes the input voltage. There is no switch for 115VAC or 230VAC, hence making Model AC300WR a completely universal input AC-voltage power supply.
  • Page 11: Section 3: Operation

    DB-25 female RS485/RS422 interface on the back panel of the unit. The location of the connector is shown in Figure 4. The Model AC300WR alarm circuitry monitors all alarms set by each circuit card and will therefore change state and oscillate whenever there is a loss of sync (such as due to a possible failure of fiber) on a FOM II card.
  • Page 12 Voltage Voltage Note Output DC voltage reduction level is reciprocal to the output frequency at the RS484/RS422 interface. As the voltage decreases from about 10V to Threshold Voltage (due to overload), the frequency respectively increases from 0Hz to 4.9Hz. www.versitron.com...
  • Page 13: Redundant Power Configurations

    This is accomplished by supplying separate power sources to the two independent AC INLETS of the Model AC300WR unit and turning ON both AC POWER switches located on the front panel. By doing this the unit will supply a combined total power of 600 Watts to the system.
  • Page 14: Section 4: Theory Of Operation

    INTRODUCTION The second generation VERSITRON fiber optic modem and interface extender products, the FOM II Series, are designed to operate with 12 VDC input power. The Model AC300WR Redundant Power Supply/System Monitor has been developed to provide adequate power for up to 20 FOM II modems in a Model HF-20A chassis.
  • Page 15: Section 5: Maintenance And Troubleshooting

    LEDs are ON but the other status indicators are not correct, first check that the 12-pin power connector from the AC300WR is fully connected to the HF-20A, i.e. the DC power cord is fully inserted into the round plug and secure.