Advertisement

Quick Links

ATAG
VA6011LT/PT
VA4511AT
VA5511AT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ATAG VA6011LT/PT and is the answer not in the manual?

Questions and answers

Summary of Contents for AEP Networks ATAG VA6011LT/PT

  • Page 1 ATAG VA6011LT/PT VA4511AT VA5511AT...
  • Page 2: Table Of Contents

    Index Technische Daten ..................... 4 Dimensions ....................... 4 Components ...................... 5 Function mode of the condensing drying............11 Repair informations ..................15 Position of Components .................. 15 Examples for Panels and Circuit Diagrams ............ 18 Instructions for Use ..................24 New Cycles and Options .................
  • Page 3 Cycle Structure ....................63 12.1 Cycles for Dishwasher without Rotary Slide Easytronic +, Control Electronic 111 573 600,111 577 800 ......63 12.2 Cycles for Dishwasher with Rotary Slide Easytronic +, Control Electronic 111 573 600,111 577 800 ......64 12.3 Cycles for Dishwasher without Rotary Slide Easytronic, Control Electronic 111 578 100,111 578 200 .......
  • Page 4: Technische Daten

    Technische Daten Dimensions Build-in dimensions for Fully Integrated Build-in dimensions for Integrated Dishwashers Dishwashers * Appliances with height-adjustable feet Plinth height for appliances 820 mm high 100 - 175 mm Plinth height for appliances 870 mm high 150 - 230 mm Dimensions for Freestanding Dishwasher Build-in dimensions for Built-Under Dishwashers...
  • Page 5: Components

    Components Circulation Pump The circulation pump is driven by an asynchronous motor with an auxiliary winding. The auxiliary winding ist in circuit with a 4 mF capacitor. A tacho generator is used for speed control. The circulation pump is driven with different rotational speeds between 1600 1/min and 2800 1/min, capacity 50 W.
  • Page 6 Flow Heater The flow heater heats the water to the required temperature. During the wash cycle, water is contantly passing through the flow heater and is located in the water circuit in front of the upper sprayarm. Power output 2100 W Resistor 25 W Protector...
  • Page 7 Detergent dispenser 2 Dosing of detergent prewash 10 ml wash 20 – 30 ml Dosing of rinse-aid position 1 – 6 2 ml – 7 ml Capacity 140 ml display “lack of rinse-aid” dosing of rinse-aid maximum filling level outlet of rinse-aid detergent tray detergent tray for prewash The detergent compartment 1 is filling corresponding to...
  • Page 8 During the rinse cycle, the coil will be switched on when the coil rinse is warmed and the rinse-aid runs from compartment 3 into the rinse tank. At the same time, the remaining rinse- time aid (15 %) runs from compartment 1 into compartment 2. With the coil switched off, the rinse-aid flows from coil compartment 2 into compartment 3.
  • Page 9 Input Module The programs are selected via the input module, which is mounted in the door. All components are connected to this module. The key layout can be vertically or horizontally. Output Module Depending on models displays are integrated into the output module.
  • Page 10 Drying Fan 1 The drying fan sucks the humid air from the tub, and mixes it with dry air which is drawn up from in between the door panels (1) and blows it out through a vent situated below the door handle (2).
  • Page 11: Function Mode Of The Condensing Drying

    Function mode of the condensing drying air guide for condenser rinse tank ventilation drain tub Rinse tank, fan and regenerating dosing with condenser form a closed circuit. The humid air is sucked from the top of the rinse tank and blown through an air guide between rinse tank and regenerating dosing. Thereby the air gets dry and the condensate is guided to the drain tub.
  • Page 12 Water Softening 1 The components required for water softening. The incoming water flows through the softener which works softener unit according to the ion exchange principle. The ion exchanger is regeneration dosage chamber filled with small epoxy resin balls. The resins exchange the hardness constituents (calcium and magnesium), for sodium ions.
  • Page 13 NTC Temperature Sensor NTC tem perature sensor 20 °C / 6032 Ω temperature/resistance 25 °C / 4829 Ω 30 °C / 3891 Ω (only w ith fully electronic 40 °C / 2573 Ω dishw ashers) 50 °C / 1741 Ω 55 °C / 1444 Ω...
  • Page 14 Turbidity Sensor The turbidity sensor function is only activated in cycles “AUTO 65° and AUTO BIO 50°”. Function: The input voltage with the turbidity sensor may be between 6 V and 11.4 V. (The measurements are described in detail in the chapter “Measuring Points at the Electronic Control (in the base)”). For a clear water the output voltage must always be 4.3 V.
  • Page 15: Repair Informations

    Repair informations Position of Components Detergent dispenser (1) Drying fan intake vent (2) Spray arms (3) input module (1) output module (2) Detergent dispenser (1) Drying fan 1 (2) Electronic (1) Thermal sensor (2) Drain pump (3) Pressure switch (4) 10.2001 A.
  • Page 16 Flow heater (1) Terminal board (2) Inlet valve (3) To remove side panel : Remove fixing screws Pull the panel away from the rear, and gently out of the front trim. Removing the regeneration dosage chamber : disengage locking tabs (1) disconnect hoses (2) holding the top of the chamber, pull upwards disengaging it from the softener.
  • Page 17 Removing the base : remove side panels, rear panel and plinth panel gently release base fixing clips with a screwdriver (figure) take off base carefully and release circulation pump, electronic and heater relay disconnect the float switch With base removed the circulation pump (1) is accessible. circuit pump turbidity sensor 10.2001 A.
  • Page 18: Examples For Panels And Circuit Diagrams

    Examples for Panels and Circuit Diagrams Easytronic + maximum equipment Control electronic 111 573 600 Circuit diagram 111 569 200 Circuit diagram 111 569 200 Circuit diagram of fully-integrated dishwashers 111 568 900 10.2001 A. B. - 18 - 599 51 21 26...
  • Page 21 Legend 10.2001 A. B. - 21 - 599 51 21 26...
  • Page 22 Easytronic + minimum equipment without sprayarm detection, turbidity sensor and rotary slide StControl electronic 111 577 800 Circuit diagram 111 527 600 Easytronic Control electronic 111 578 100 Circuit diagram 111 527 600 10.2001 A. B. - 22 - 599 51 21 26...
  • Page 24: Instructions For Use

    Instructions for Use New Cycles and Options “Eat – Load – Run” new 30 minute cycle incl. washing and drying with covered fan running at the cycle end (max. 20 minutes) “tablets” specially suited for detergents containing enzymes structure similar to the bio-phase with washing appliances addition of rinse-aid The addition of rinse-aid can be switched off by the user.
  • Page 25: Displays Of Cycle Run And Condition

    Tastenausführung Die Ein/Aus-Taste ist als Netzschalter mit Überhub-Funktion ausgeführt, alle anderen möglichen Tasten sind „Knackfrösche“ auf der Leiterplatte. Die Anlieferung der Ein- und Ausgabemodule erfolgt ohne Tastenkappen. Quittierungen und Anzeigen Alle Tastenquittierungen erfolgen über LED-Anzeigen. Die Startzeitvorwahl bzw. Laufzeitanzeige wird mittels einer 7-Segmentanzeige dargestellt.
  • Page 26: Input

    Input Before the start Switch on the appliance with the ON/OFF key – LED next to the ON/OFF key lights. appliance is in the pre-start mode all cycle keys are unlocked and can be actuated resp. set After actuating a cycle key, all belonging rinse cycle parts light during this mode by means of cycle run display LEDs and the cycle LED.
  • Page 27 Change cycle (after a successful cycle start) The cycle can be changed after the cycle start at any time. The new set cycle is executed from the very beginning! Actuate the key of the desired new cycle for approx. 3 seconds. During the time is changed, the LEDs of the previous and of the new cycle will flash.
  • Page 28 What happens when opening and closing the door? The appliance is switched on and is in the “pre-start mode”. After opening, all displays (see Instructions Point 3 “Before the start”) continue to light on the panel. The power supply of the electronics is fully guaranteed as long as the appliance keeps to be switched on by the ON/OFF key.
  • Page 29: Set The Water Softener

    Cycle End The confirmation LED of the cycle key and the option key of the finished cycle continue to light. Depending on model, the LED “end” will light resp. the digit “0” will be indicated by the 7- segment display at the end of the cycle. If existing, the LED “running time” will go out. Only for “VGA”...
  • Page 30 Set the water softener according to the table to the water hardness of your residential district: EI N AU S Key layout, vertically Key layout, horizontally EI N AU S Key layout, VGA EI N The dishwasher must be switched on. Mechanical setting: Open door of dishwasher.
  • Page 31: Switching Off The Buzzer

    Switching off the buzzer EI N AU S Key layout, vertically Key layout, horizontally EI N AU S General information The buzzer is switched off resp. on analogously in all designs resp. key layouts. For that you always have to use the keys T1 to T3, independent of its model-relevant cycle loads. Whether the buzzer is switched on resp.
  • Page 32 Easytronic plus VGA - Easytronic plus call service function set function buzzer switch on/off buzzer b1 or “END” = buzzer b0 or “END” off = buzzer off store function and switch off automatically 60 seconds after the last change...
  • Page 33 Easytronic plus VGA - Easytronic plus Press keys T2 and T3 simultaneously and ... Press keys T2 and T3 simultaneously and ..keep them pressed until the appliance is ...keep them pressed until the appliance is switched on by the ON/OFF key T1. The key switched on by the ON/OFF key T1.
  • Page 34: Rinse-Aid Addition

    Rinse-Aid Addition EI N AU S Key layout, vertically Key layout, horizontally EI N AU S Key layout, VGA EI N General information Deactivating resp. activating the rinse-aid addition is executed analogously in all designs resp. key layouts. For that you always have to use keys T1 to T4, independent of their model-relevant cycle load. The display whether the rinse-aid addition is active or not, is indicated differently depending on the model, i.e.
  • Page 35 Easytronic plus VGA - Easytronic plus call service function switch on/off rinse-aid addition set function rinse-aid d1 or “END” = rinse-aid addition on d0 or “END” off = rinse-aid addition off store function and switch off automatically 60 seconds after the last change...
  • Page 36 Easytronic plus VGA - Easytronic plus Press keys T2 and T3 simultaneously and ... Press keys T2 and T3 simultaneously and ..keep them pressed until the appliance is ...keep them pressed until the appliance is switched on by the ON/OFF key T1. The key switched on by the ON/OFF key T1.
  • Page 37: Function Of "Superwash" Or "Soaking" Options

    Function of “superwash” or “soaking” options Can be selected additionally to which washing cycles? By the separate option key, which is located on the right side of the appliance (output side), it is possible to set the function “soaking” resp. “superwash” in addition to following washing cycles.
  • Page 38: New Automatic Cycles

    Water Energy Time Prewash Wash Final Drying intermed. intermed. rinse rinse rinse Full load 65°C 70°C 19,0 L 1,45 kWh 105 min 10 min 36 min 7 min 5 min 23 min 24 min very polluted water Full load 15,5 L 1,35 kWh 97 min 65°C...
  • Page 39: Fuzzy Detection Of Load

    4.10 Fuzzy Detection of Load water temperature fast heating without resp. half load is assumed heating takes more time full load is assumed measuring phase 1 measuring phase 2 time heating 3 min 3 min in seconds time in seconds Cycles with active Fuzzy detection: normal 65°...
  • Page 40: Energy Label Aaa

    4.11 Energy Label AAA In order to be able to lead the optimum value “AAA”, among others following features have to exist and/or conditions to be made. Drying by Fan To get a very good drying result, a fan drying is absolutely necessary. Positioning of Sprayarm At the end of the final rinse, the middle sprayarm is in a defined position.
  • Page 41: Eat, Load And Run

    4.12 “Eat, Load and Run” This means to load the dishwasher immediately and start after the meal. Why this cycle? The declaration cycles as technical standard have remarkably extended due to the requirements regarding energy label and the use of the flow-type heater. “Eat, Load and Run” is to comply with the customer`s wishes for a quick cycle for the washing of household-usual loads with dishes, glasses and cutlery.
  • Page 42: Function Of "Tablets" Option

    4.13 Function of “Tablets” Option Why this option? The use of detergent tablets is essentially optimized. Characteristics of this option An additional enzyme step is inserted during washing at 40°C. This enzyme phase takes 5 minutes. temperature without “tablets” option time in seconds temperature...
  • Page 43: Water Course Scheme

    Water Course Scheme Inlet valve Float switch Air break Pressure switch Regeneration water dosage Filter Overflow safety level Circulation pump Safety overflow Flow heater Inlet to sump from regeneration dosage Drain pump chamber Non-return valve Regeneration dosage chamber Spray arms Softener ceiling shower / ceiling sprayarm Salt container...
  • Page 44: All-Around Water Protection

    All-Around Water Protection Aqua-Control Inlet Hose The inlet hose has a double-wall construction. The inner hose is equipped with a flow restrictor built into the tap connection, and has a flow rate of 4 litres per minute. The inlet valve (1) is located in the base of the dishwasher. The safety outer hose (12) is connected to the regeneration chamber.
  • Page 45: All-Around Water Protection

    All-Around Water Protection Inlet valve Float switch Air break Pressure switch Regeneration water dosage Filter Overflow safety level Circulation pump Safety overflow Flow heater Inlet to sump from regeneration dosage Drain pump chamber Non-return valve Regeneration dosage chamber Spray arms Softener ceiling shower / ceiling sprayarm Salt container...
  • Page 46: Pulsed Washing

    Pulsed Washing Dishwashers with Rotary Slides have pulsed washing 1 only in the final rinse cycle. During the pulsed washing 1, the circulation pump runs at 1600 1/min 4 seconds at 2800 1/min 0.8 seconds During the first washing cycles, the circulation pump runs at 2800 1/min Dishwashers without Rotary Slides have pulsed washing 1 in all washing cycles.
  • Page 47 For pulsed washing 2 Easytronic + Control electronic 111 573 600 / 111 577 800 Cycle phases Phase Function Time Circulation pump static filling to level static filling 15 seconds dynamic filling 5 seconds 1700 1/min level monitored pause 5 seconds dynamic filling 15 seconds 1700 1/min...
  • Page 48: Water Intake And Pulsed Washing

    Water Intake and Pulsed Washing speed in 1/min 60 seconds time in seconds water in l dynamic filling temporal filling pre-filling static filling time in seconds valve re-filling filling possible time in seconds 10.2001 A. B. - 48 - 599 51 21 26...
  • Page 49: Water Course Scheme For Water Intake

    Water Course Scheme for Water Intake The water flows over via inlet valve (1), condenser (26), air break (2), regeneration water dosage (3). After the regeneration water dosage is filled, the water divides. 85 % of the water flows through the softener (8), regeneration dosage chamber (7), hose (6), sump assembly (24) into the tub.
  • Page 50: Pumping Out

    Pumping Out During the wash cycle the water is pumped out at various stages. First the draining water cleans the filters (16). The filters are open at the bottom which allows any soilage to be rinsed off sufficiently. There is a non-return valve (20) at the inlet connection to the drain pump (19).
  • Page 51: Water Course Scheme For Pumping Out

    Water Course Scheme for pumping out Inlet valve Float switch Air break Pressure switch Regeneration water dosage Filter Overflow safety level Circulation pump Safety overflow Flow heater Inlet to sump from regeneration dosage Drain pump chamber Non-return valve Regeneration dosage chamber Spray arms Softener ceiling shower / ceiling sprayarm...
  • Page 52: Regeneration

    10. Regeneration The water chamber for regeneration (3) contains 350 ml water. During regeneration, the regeneration valve (11) is energized. The 350 ml water runs into the salt container (9) and mixes with the salt to form a brine solution. In the top of the salt container there is an opening with a small filter, from here the brine solution passes through a non-return valve (10) and enters the softener (8) where the resins are regenerated.
  • Page 53 Easytronic, Control Electronic 111 578 100, 111 578 200 Phases Function Time Comment drying, pumping 5 sec renerating, drying 240 sec pumping, drying 15 sec drying 300 sec filling to level * rinse out softener pause 5 sec pumping, filling 5 sec * rinse out softener pumping...
  • Page 54: Water Course Scheme For Regenerating

    10.2 Water Course Scheme for Regenerating Inlet valve Float switch Air break Pressure switch Regeneration water dosage Filter Overflow safety level Circulation pump Safety overflow Flow heater Inlet to sump from regeneration dosage Drain pump chamber Non-return valve Regeneration dosage chamber Spray arms Softener ceiling shower / ceiling sprayarm...
  • Page 55: Service Functions

    11. Service Functions 11.1 Call for the Manufacturing Test Routine EI N AU S EI N EI N AU S Activate the basic function by keys T1, T2 and T4 Start the manufacturing test routine by key 4 First you have to press keys 2 and 4 and keep them pressed until switching on the appliance by the ON/OFF switch T1.
  • Page 56 Test Routine for Dishwasher with Rotary Slide Drive without Automatic Easytronic +, Control Electronic 111 573 600 / 111 577 800 Phase Function Time prewash pumping to reset point pumping 15 sec static filling to level static filling 5 sec pumping to reset point pumping...
  • Page 57 Test Routine for Dishwasher without Rotary Slide Drive without Automatic Easytronic +, Control Electronic 111 573 600 / 111 577 800 Phase Function Time prewash pumping to reset point pumping 15 sec static filling to level static filling 5 sec pumping to reset point pumping...
  • Page 58: Call For Selection Of Single Actuators

    11.2 Call for Selection of Single Actuators EI N AU S EI N EI N AU S Activate the basic function by keys T1, T2 and T5 Start the manufacturing test routine by key T2 First you have to press keys 2 and 5 and keep them pressed until switching on the appliance by the ON/OFF switch T1.
  • Page 59: Deleting The Fault Memory And Led Test

    11.4 Deleting the Fault Memory and LED Test EI N AU S EI N EI N AU S Activate the basic function by keys T1, T2 and T5 Call for the service fault memory using key T5. First you have to press keys 2 and 5 and keep them pressed until switching on the appliance by the ON/OFF switch T1.
  • Page 60: Survey Of Fault Indications - Display C

    Error Indication Display Display Display Fault Indication Inquiry Indication over Reference Short Description What happens? 7-Segment PAA - LEDs Acoustic visible for Fault Memory Display customers (after-sales number of squealings service) Either 7-segment or PAA if existing if existing possible! depending on Seg.
  • Page 61: Survey Of Fault Indications - Display A

    Error Indication Display Display Display Fault Indication Inquiry Indication over Reference Short Description What happens? 7-Segment PAA - LEDs Acoustic visible for Fault Memory Display number of customers (after-sales squealings service) Either 7-segment or PAA if existing if existing possible! depending on Seg.
  • Page 62: Short Survey Of Service Functions

    activation of basic function afterwards: selection, start or change of function by key(s) display by key display before key 1 (ON/OFF) is actuated set hardness area key 2 + 3 LEDs 2 and 3 flashing The hardness area value can be changed by actuating key 3 (LED 3 is flashing). When actuating it the first time, the currently set value will be indicated.
  • Page 63 options pre wash main wash cold rinse hot rinse drying $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ Optionen Vorspülen Reinigen Zwischenspülen Klarspülen Trocknen programs Programme ∆ ∆ ∆ ∆ super wash ∆...
  • Page 64 options pre wash main wash cold rinse hot rinse drying $ $ $ $ $ $ $ $ Optionen Vorspülen Reinigen Zwischenspülen Klarspülen Trocknen programs Programme " ∆ ∆ ∆ ∆ super wash ∆ T + 11 ∆ T + 6 ∆...
  • Page 65 options cold rinse pre wash main wash hot rinse drying $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ Optione Zwischenspüle Vorspülen Reinigen Klarspülen Trocknen programs abbr. Abkürz. Programme [min] [min] [min] [min] [kWh] super wash 55 °C...
  • Page 66: Legend

    12.4 Legend heating time + 10 minutes ctrol recirculation 2800 1/min PulsN pulsed washing 1 / pulsed washing 2 New Fan fan with condenser drying fully integrated dishwasher 13. Measuring points to the input 3-pole 4-pole 4-pole 4-pole to the input 7-pole connector module connector...
  • Page 67 AEP Home Products Impact 54 – 6921 RZ Postbus 249 – 6920 AE Duiven – Nederland...

This manual is also suitable for:

Atag va5511atAtag va4511at

Table of Contents