Control Port Functions - Sanyo DP42840 Service Manual

Hide thumbs Also See for DP42840:
Table of Contents

Advertisement

System Control (CPU : IC800)
PIN
IC specification
1
P12/SCK0
2
P13/SO1
3
P14/SI1/SB1
4
P15/SCK1
5
P16/T1PWML
6
P17/T1PWMH/BUZ
7
PWM2
8
PWM3
9
VDD2
10
VSS2
11
P00
12
P01
13
P02
14
P03
15
P04
16
P05/CKO
17
P06/T6O
18
P07/T7O
19
P20/UTX/INT4/T1IN
20
P21/URX/INT4/T1IN
21
P22/INT4/T1IN
22
P23/INT4/T1IN
23
P24/INT5/T1IN
24
P25/INT5/T1IN
25
P26/INT5/T1IN
26
P27/INT5/T1IN
27
PB7
28
PB6
29
PB5
30
PB4
31
PB3
32
PB2
33
PB1
34
PB0
35
VSS3
36
VDD3
37
PC7
38
PC6
39
PC5
40
PC4
41
PC3/AN11
42
PC2/AN10
43
PC1/AN9
44
PC0/AN8
45
P86/AN6
46
P85/AN5
47
P84/AN4
48
P83/AN3
49
P70/INT0/T0LCP
50
P71/INT1/T0HCP
51
P72/INT2/T0IN

CONTROL PORT FUNCTIONS

Assignment
I/O
REG SW4
OUT
REG SW5
OUT
IIC-BUS for NV
I/O
IIC-BUS for NV
OUT
REG SW2
OUT
REG SW3
OUT
illumination
OUT
no use (PWR_DET)
IN
Power IN
IN
Vss
IN
Category2
IN
Category1
IN
Category0
IN
Panel Size2
IN
Panel Size1
IN
Panel Size0
IN
LED CNTRL
OUT
TV Relay out
OUT
UART OUT
OUT
UART IN
IN
PC Standby LED
OUT
Audio MUTE
OUT
Power Fail-2 IN
IN
AMP_STBY
OUT
HS_DET
IN
VS_DET
IN
RESET_TV
OUT
Boot_SEL1
OUT
Boot SEL2
OUT
M_OUT MUTE
OUT
LINE OFF_DET
OUT
Reserve
OUT
Reserve
OUT
Solution
IN
Vss
IN
Power IN
IN
DBGP2
IN
DBGP1
I/O
DBGP0
I/O
CLK
OUT
DATA0
I/O
ENA/DATA1
I/O
Ack out
OUT
STATUS in
IN
sensor in
IN
Reserve
OUT
Panel Alarm
IN
Power Fail-1 IN
IN
LINE OFF
IN
CEC input
IN
CEC output
OUT
Explanation
no use (REG SW4)
no use (REG SW5)
Data of IIC Bus Active 'L' for IIC data NV
Clock of IIC Bus Active 'L' for IIC clock NV
REG SW2 (ON : High OFF : Low)
REG SW3 (ON : Low OFF : High)
no use (illumination LED output )
no use (PWR DET)
VDD2 (5Vdc±10%)
GND (0Vdc)
Hard option for category (See other sheet,Zoran/BRCM model)
Hard option for category (See other sheet,Zoran/BRCM model)
Hard option for category (See other sheet,Zoran/BRCM model)
Hard option for panel size (See other sheet,Zoran/BRCM model)
Hard option for panel size (See other sheet,Zoran/BRCM model)
Hard option for panel size (See other sheet,Zoran/BRCM model)
LED Control output for Power indicater
POWER Relay control output ON : High OFF : Low
Output of UART(Digital Module microcomputer piece confidence )
Input of UART (Digital Module microcomputer piece confidence)
LED control of PC Standby High_Noraml_Low
Audio Mute
MUTE ON : Low OFF : High
no use (LVDS Power Fail input for LCD model)
no use (AMP Standby control)
Detect H-Sync (Detect : High , PC Input)
Detect V-Sync (Detect : High , PC Input)
RESET_TV => for DM Watch Dog Timer
no use (Starting DM S/W download-SEL1 for US1T model)
no use (Starting DM S/W download-SEL2 for US1T model)
MUTE ON:Low OFF:High
Detect LINE OFF output(Detect: High -> Low)
Reserve (Set Low level)
Reserve (Set Low level)
High:AMD
Low:Zoran
GND (0Vdc)
VDD3 (5Vdc±10%)
Terminal for De-Bug 3
Terminal for De-Bug 2
Terminal for De-Bug 1
Writing on bord (CLK)
Writing on bord (DATA0)
Writing on bord (ENA/DATA1)
Ack output for factory mode
Status input for factory mode
Light sensor input
(OPEN) (Set Low level)
no use (Panel Alarm)
TV Power Error(3.6V less)/Others (3.6V over)
Detect AC Voltage Reduction (Normal : High)
CEC input
CEC output
– 38 –