Overview Thank you for purchasing this ubisys ZigBee Router. You have decided for a high-quality product with first-rate support! This reference manual provides operating and maintenance instructions, interface specifications, command references and more. It is primarily intended for system integrators, not end-users.
On-board PHY: Texas Instruments CC2520, 5dBm transmit power, -98dBm receiver sensitivity On-board inverted-F antenna Leverages ubisys IEEE 802.15.4 MAC and ZigBee stack for best-in-class reliability and performance Supports all channels in the 2.4 GHz band, i.e. channels 11-26 as per IEEE 802.15.4...
(the green LED will flash a few times). The built-in universal power supply can accept up to 400V=, which is an absolute maximum rating. If you are not using a safe low-voltage power-supply, utilizing the services of a professional installer/electrician is imperative. www.ubisys.de...
After joining a network, the device will prolong the joining window by three minutes via a fresh ZDO permit joining request Stretching the joining duration is done in products with ubisys ZigBee Stack version 1.48 or above. ...
The 10-second-press factory reset (equivalent to menu item #5) is available since firmware version 1.02. Notice: Prior versions have different menu items. Only the factory reset command (menu item #5) is identical across all released versions of the firmware. www.ubisys.de...
Page 8
Option #3: Perform a full factory reset, including security frame counters and preserved settings Reserved for internal use. Do not leave the menu in this mode. Since application firmware 1.03. Previously, the factory reset would result in a silent leave. www.ubisys.de...
When available, it will be provided as ZigBee over-the-air upgrade image for already deployed devices. The ubisys ZigBee manufacturer ID is 0x10F2. This manufacturer code is used to identify OTA upgrade images, for accessing manufacturer-specific ZCL attributes and commands etc.
Page 10
0F 7C 1C D8 05 F9 16 49 EB A8 45 80 AA 1C B4 32 F5 1A = 21 Notice: The data format “ubisys1” is identical to “ubisys2” except for the check sum, which is present, but invalid. If you encounter “ubisys1” labels, then do not verify the trailing check sum field. www.ubisys.de...
ZigBee Device Profile (ZDP). Notice that the ZDP is fundamentally different from typical application endpoints, which build on the ZigBee foundation framework and the ZigBee Cluster Library (ZCL). The ubisys ZigBee Router R0 supports the following ZDO services: Primitive Description...
Always set to mains-powered, single phase (regardless of the connected supply voltage) 0x0010 string, persistent LocationDescription Only in Version 1.00. Later versions of R0 do not include the Identify server cluster any more. Other ubisys products include the client side of Identify for Finding & Binding. www.ubisys.de...
OTA server and back-end. If you operate the Router R0 together with the ZigBee/Ethernet Gateway ubisys G1, the latest firmware for R0 will always be available automatically and you do not need to request it explicitly.
Ordering Information The following tables list the product variants available. Use the specified order code for your orders. Please contact ubisys support if you require any customization. Order Code Description 1182 ZigBee Router R0 The housing is flame retardant (V-0), Color: Black, RAL 9005.
10. General Terms & Conditions of Business When placing your order you agree to be bound by our General Terms & Conditions of Business, “Allgemeine Geschäftsbedingungen”, which are available for download here: http://www.ubisys.de/en/smarthome/terms.html www.ubisys.de...
We – ubisys technologies GmbH, Am Wehrhahn 45, 40211 Düsseldorf, Germany – declare under our sole responsibility that the ubisys ZigBee Router R0 with order codes as detailed in section 9 under the trade name “ubisys” to which this declaration relates are in conformity with the following directives...
10-second extended press. 11/02/2015 Starting with firmware revision 1.03, when the device is factory reset, it will broadcast a network leave indication 11/11/2015 Updated the ZDO description to include enhancements and additions made for ZigBee 2015 platform compliance www.ubisys.de...