  • Page 1 ZIGBEE ROUTER R0 REFERENCE MANUAL  ...
  • Page 2: Overview

    Overview Thank you for purchasing this ubisys ZigBee Router. You have decided for a high-quality product with first-rate support! This reference manual provides operating and maintenance instructions, interface specifications, command references and more. It is primarily intended for system integrators, not end-users.
  • Page 3: Table Of Contents

    Application Endpoint #232 – Device Management 7.2.1. Basic Cluster (Server) 7.2.2. Identify Cluster (Server) 7.2.3. Commissioning Cluster (Server) 7.2.4. Over-the-Air Upgrade Cluster (Client) Physical Dimensions Ordering Information General Terms & Conditions of Business Declaration of Conformity Revision History Contact  www.ubisys.de...
  • Page 4: Features

    On-board PHY: Texas Instruments CC2520, 5dBm transmit power, -98dBm receiver sensitivity On-board inverted-F antenna Leverages ubisys IEEE 802.15.4 MAC and ZigBee stack for best-in-class reliability and performance Supports all channels in the 2.4 GHz band, i.e. channels 11-26 as per IEEE 802.15.4...
  • Page 5: Installation

    (the green LED will flash a few times). The built-in universal power supply can accept up to 400V=, which is an absolute maximum rating. If you are not using a safe low-voltage power-supply, utilizing the services of a professional installer/electrician is imperative.  www.ubisys.de...
  • Page 6: Initial Device Start-Up

    After joining a network, the device will prolong the joining window by three minutes via a fresh ZDO permit joining request Stretching the joining duration is done in products with ubisys ZigBee Stack version 1.48 or above. ...
  • Page 7: Man-Machine Interface (Mmi)

    The 10-second-press factory reset (equivalent to menu item #5) is available since firmware version 1.02. Notice: Prior versions have different menu items. Only the factory reset command (menu item #5) is identical across all released versions of the firmware.  www.ubisys.de...
  • Page 8 Option #3: Perform a full factory reset, including security frame counters and preserved settings Reserved for internal use. Do not leave the menu in this mode. Since application firmware 1.03. Previously, the factory reset would result in a silent leave.  www.ubisys.de...
  • Page 9: Zigbee Interface

    When available, it will be provided as ZigBee over-the-air upgrade image for already deployed devices. The ubisys ZigBee manufacturer ID is 0x10F2. This manufacturer code is used to identify OTA upgrade images, for accessing manufacturer-specific ZCL attributes and commands etc.
  • Page 10 0F  7C  1C  D8  05  F9  16  49  EB  A8  45  80  AA  1C  B4  32  F5  1A = 21 Notice: The data format “ubisys1” is identical to “ubisys2” except for the check sum, which is present, but invalid. If you encounter “ubisys1” labels, then do not verify the trailing check sum field.  www.ubisys.de...
  • Page 11: Application Endpoint #0 - Zigbee Device Object

    ZigBee Device Profile (ZDP). Notice that the ZDP is fundamentally different from typical application endpoints, which build on the ZigBee foundation framework and the ZigBee Cluster Library (ZCL). The ubisys ZigBee Router R0 supports the following ZDO services: Primitive Description...
  • Page 12: Application Endpoint #232 - Device Management

    Always set to mains-powered, single phase (regardless of the connected supply voltage) 0x0010 string, persistent LocationDescription Only in Version 1.00. Later versions of R0 do not include the Identify server cluster any more. Other ubisys products include the client side of Identify for Finding & Binding.  www.ubisys.de...
  • Page 13: Identify Cluster (Server)

    OTA server and back-end. If you operate the Router R0 together with the ZigBee/Ethernet Gateway ubisys G1, the latest firmware for R0 will always be available automatically and you do not need to request it explicitly.
  • Page 14: Physical Dimensions

    Physical Dimensions Figure 1: Flush-mounted In-wall ZigBee Router R0 – Dimensions  www.ubisys.de...
  • Page 15: Ordering Information

    Ordering Information The following tables list the product variants available. Use the specified order code for your orders. Please contact ubisys support if you require any customization. Order Code Description 1182 ZigBee Router R0 The housing is flame retardant (V-0), Color: Black, RAL 9005.
  • Page 16: General Terms & Conditions Of Business

    10. General Terms & Conditions of Business When placing your order you agree to be bound by our General Terms & Conditions of Business, “Allgemeine Geschäftsbedingungen”, which are available for download here: http://www.ubisys.de/en/smarthome/terms.html  www.ubisys.de...
  • Page 17: Declaration Of Conformity

    We – ubisys technologies GmbH, Am Wehrhahn 45, 40211 Düsseldorf, Germany – declare under our sole responsibility that the ubisys ZigBee Router R0 with order codes as detailed in section 9 under the trade name “ubisys” to which this declaration relates are in conformity with the following directives...
  • Page 18: Revision History

    10-second extended press. 11/02/2015 Starting with firmware revision 1.03, when the device is factory reset, it will broadcast a network leave indication 11/11/2015 Updated the ZDO description to include enhancements and additions made for ZigBee 2015 platform compliance  www.ubisys.de...