Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6 MPK1-14ER-QB6...
Andi-Co Australia Pty Ltd Service manual for K1 portable Series 1. PREFACE This SERVICE MANUAL provides various servicing information, including the mechanical and electrical parts, etc. This room air conditioner was manufactured and assembled under a strict quality control system.
Page 4
Andi-Co Australia Pty Ltd Service manual for K1 portable Series M ODE Mode setting button. Push this button to select the operation mode: Cool, Dry, Fan only and Heat High fan speed lamp. Med fan speed lamp. Low fan speed lamp.
Andi-Co Australia Pty Ltd Service manual for K1 portable Series 2 TROUBLESHOOTING GUIDE 2.1 REFRIGERATION CYCLE DIAGRAM 2.2 ELECTRICAL FUNCTION 2.2.1 Electric Control working environment Both temperature mode display 2.2.1.1 Input voltage: 187~264V for 50Hz models 2.2.4 Protection and 97~127V for 60Hz models;...
Page 6
Andi-Co Australia Pty Ltd Service manual for K1 portable Series on for 10 seconds, the whole unit will stop 2.2.8.1 The speed of indoor fan can be optionally operation. The LED will display “P2” and the chosen as High/Mid/Low. water full lamp will flash at 5Hz. After you have 2.2.8.2 Electric heater operate as :...
Page 7
Andi-Co Australia Pty Ltd Service manual for K1 portable Series ROOM AIRCONDITIONER VOLTAGE LIMITS: NAMEPLATE RATING MINIMUM MAXIMUM 220~240V 196V 253V PROBLEM POSSIBLE CAUSE REMEDY Check the power supplier if the power supplier is supplied to the Power failure unit. Check the power cord and correct if damaged.
Page 8
Andi-Co Australia Pty Ltd Service manual for K1 portable Series Replace the fan blower if cracked, out of balance, or partially Fan blower missing. Loose screws Tighten them. Fan motor noise. Replace the motor if knocking sounds continue when running or...
Andi-Co Australia Pty Ltd Service manual for K1 portable Series The inlet and outlet valve of the compressor is damaged, making the low pressure connected with the high pressure. The Compressor refrigerating system can not produce high pressure and low pressure.
Andi-Co Australia Pty Ltd Service manual for K1 portable Series 4 HOW TO DISASSEMBLE THE UNIT 4.1 Prepare the unit. Unplug the power cord and disconnect the Air pipe from rear of the unit. Move the unit to a replace where water can be poured.
Page 15
Andi-Co Australia Pty Ltd Service manual for K1 portable Series Take care to the indoor temperature sensor attached on the rear board. And be care to the power cord which got through the rear panel. 4.3 To disassemble the display board assembly, just push the clasp and release the assembly.
Page 16
Andi-Co Australia Pty Ltd Service manual for K1 portable Series the display board. 4.5 To replace the Main Control board. Remove the screws fixing the enclosure cover. Take care of the wiring diagram on the cover. The wiring diagram is important for reference when wiring.
Page 17
Andi-Co Australia Pty Ltd Service manual for K1 portable Series Remove the fan motor, fan scroll and blower wheel 4.7 To replace the evaporator fan motor or from the unit. electric heater To disassemble the air-out frame. Remove the screws fixing the air-out frame. Lift the frame up then pull the frame forward.
Page 18
Andi-Co Australia Pty Ltd Service manual for K1 portable Series 4.8 To replace the condenser fan motor 4.9 To repair the refrigerant system or replace Remove the screws fixing the evaporator the compressor Disconnect the water pipe below. Remove the screws fixing the condenser fan motor Remove the screws fixing the condenser fan scroll.
Page 19
Andi-Co Australia Pty Ltd Service manual for K1 portable Series 4.10 To repair the water disposal system or replace the water depth switch or the pump. Remove the screws fixing the supporting board. Remove the screw fixing the pump clamp.
Page 20
Andi-Co Australia Pty Ltd Service manual for K1 portable Series Remove the screw fixing the water switch which Then remove the screws fixing the switches and controls the water in tank. replace. Pay attention to the holes. Don’t install into wrong holes.