Steco ARTA series Installation, Operation & Maintenance Manual

Wood and coal

Advertisement

REV.01 / 2012 122088

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ARTA series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Steco ARTA series

  • Page 1 REV.01 / 2012 122088...
  • Page 2 CAUTION! Observe the safety instructions of this installation maintenance manual before placing the boiler in operation. If an unqualified person carries out installation, adjustment, modification, operation or maintenance of the heating system, this may result in danger to life limb property damage.
  • Page 3: Table Of Contents

    Warranty and warranty conditions Introduction Boiler delivery Ensuring safety of equipment and people Installation instructions Operating instructions Boiler installation – General information ARTA series boiler general features Heating water requirements Recommended fuel Boiler Location Control and safety devices Minimum distance Thermo-mechanical regulator...
  • Page 4: Information On The Boilerplate

    Information on the boilerplate The boiler serial no is shown on the plate which is attached to the backside cover panel of the boiler body. 20, 26, 35, 43...
  • Page 5: Boiler Dimensions

    Boiler dimensions...
  • Page 6: Boiler Packaging

    Boiler packaging...
  • Page 7: Technical Parameters

    Technical parameters...
  • Page 8: Introduction

    Introduction Check the delivery for completeness. The boiler and all associated equipment must be installed and used in accordance 8. Check whether the model and type supplied with the installation design, all applicable is suitable for the required use. legal regulations and technical standards and with the manufacturer’s instructions.
  • Page 9: Ensuring Safety Of Equipment And People

    If it is necessary to drain water from the • ARTA series solid fuel fired boiler is boiler or from the whole system, the water designed for heating both residential and must not be dangerously hot;...
  • Page 10: Control And Safety Devices

    Fuel must be stored in a dry place. To reach When fitting the safety and the control the boiler nominal output, water content in elements remember to meet the principles of firewood must not exceed 20%. work safety. Approximate stoking intervals (referred to as burning time) are shown in the technical data If replacing of safety device and of thermo...
  • Page 11: Air Rosette

    Air rosette Supply of secondary combustion air is whether there are any leakage in the heating controlled by an air rosette situated in the system; boiler’s stoking door, which has a direct effect Connection to the chimney - connection must on the level of emission.
  • Page 12: Operation And Controls

    During the heating season, a constant heat from unnecessarily escaping into the volume of water must be maintained inside chimney. the heating system. When topping up water, care must be taken that no air is sucked into the system. Water must never be let out of the boiler or the heating system, unless it is absolutely essential, such as before repairs, etc.
  • Page 13: Overnight Heating Mode

    Only then open the stoking door completely Dewing and tarring and start stoking the boiler. After shutting the stoking door, set the chimney flap again and When starting fire in a cold boiler, water restore the functioning of the regulating condensates on the walls and runs down into hatch.
  • Page 14: Long-Term Shutdown

    Boiler delivery Important information ARTA series boilers are supplied completely assembled and functionally tested. • An adult person familiar with these The delivery includes: operating Instructions may only operate the boiler.
  • Page 15: Heating Water Requirements

    The heating system must be designed in • The pipe used in by-pass line must be at such a way that hot water can circulate all the least in the diameter of plumbing systems time through at least some of the radiators. pipe.
  • Page 16: Minimum Distance

    • On a non-flammable material overlapping the boiler footprint by 20 mm on each side and covering the entire depth of the boiler Do not put flammable materials on top of the body. boiler or near the boiler than specified safety distance.
  • Page 17: Chimneys And Chimney Connection Warnings

    • The effective chimney flue height measured from the point of entry of the flue pipe into the chimney. • Ensure that the calculation of the flue gas path and the connection of the flue gas system are only carried out by qualified personnel.
  • Page 18 Fig. 07 shows the proper flue gas connection with additional air equipment. Observe the Coefficient = 0,041 ( for wood ) following during the installation of the flue gas connection: Coefficient = 0,027 ( for carbon ) = Sections resulting (cm2) = Coefficient •...
  • Page 19: Accumulator Tank Capacity

    Accumulator tank capacity NOTE: The heat can be supplied for example by an accumulator tank. The following applies as a reference for the minimum storage boiler content: : Accumulator tank capacity in L : Nominal heat output in kW : Burning period in h : Heating load of the premises in kW : Minimum heat output in kW Fig.
  • Page 20: Boiler Cleaning

    If a larger quantity of tar has accumulated on internal walls of the combustion chamber, it must be removed with a scraper or burnt with Warning ! hard wood (or coke), running the boiler at maximum operating temperature. • Risk of injury from carrying heavy loads! •...
  • Page 21: Ash Pan Cleaning

    • Open the ash pan door. • Remove the combustion residues from the ash pan with the ash shovel. • Do not place hot ashes in plastic and waste containers. Fig. 11 Ash pan cleaning The ashes must be removed from the combustion chamber/ash pan every 1 –...
  • Page 22: Hydraulic Connection Diagrams

    Hydraulic Connection Diagrams...
  • Page 23: Boiler Combustion System

    If the air vent is closed completely, there is no complete combustion. Creosote accumulates on the heating surfaces, which requires more cleaning effort. 1. Primary air inlet 2. Secondary air inlet Fig. 13 ARTA series solid fuel boiler is designed as a three pass. Fig. 14...
  • Page 24: Arta Boiler Parts

    ARTA boiler parts...
  • Page 25: Arta Boiler Spare Parts Lists

    ARTA boiler spare parts lists...
  • Page 27: Troubleshooting

    Troubleshooting...