CAUTION! Observe the safety instructions of this installation maintenance manual before placing the boiler in operation. If an unqualified person carries out installation, adjustment, modification, operation or maintenance of the heating system, this may result in danger to life limb property damage.
Warranty and warranty conditions Introduction Boiler delivery Ensuring safety of equipment and people Installation instructions Operating instructions Boiler installation – General information ARTA series boiler general features Heating water requirements Recommended fuel Boiler Location Control and safety devices Minimum distance Thermo-mechanical regulator...
Information on the boilerplate The boiler serial no is shown on the plate which is attached to the backside cover panel of the boiler body. 20, 26, 35, 43...
Introduction Check the delivery for completeness. The boiler and all associated equipment must be installed and used in accordance 8. Check whether the model and type supplied with the installation design, all applicable is suitable for the required use. legal regulations and technical standards and with the manufacturer’s instructions.
If it is necessary to drain water from the • ARTA series solid fuel fired boiler is boiler or from the whole system, the water designed for heating both residential and must not be dangerously hot;...
Fuel must be stored in a dry place. To reach When fitting the safety and the control the boiler nominal output, water content in elements remember to meet the principles of firewood must not exceed 20%. work safety. Approximate stoking intervals (referred to as burning time) are shown in the technical data If replacing of safety device and of thermo...
Air rosette Supply of secondary combustion air is whether there are any leakage in the heating controlled by an air rosette situated in the system; boiler’s stoking door, which has a direct effect Connection to the chimney - connection must on the level of emission.
During the heating season, a constant heat from unnecessarily escaping into the volume of water must be maintained inside chimney. the heating system. When topping up water, care must be taken that no air is sucked into the system. Water must never be let out of the boiler or the heating system, unless it is absolutely essential, such as before repairs, etc.
Only then open the stoking door completely Dewing and tarring and start stoking the boiler. After shutting the stoking door, set the chimney flap again and When starting fire in a cold boiler, water restore the functioning of the regulating condensates on the walls and runs down into hatch.
Boiler delivery Important information ARTA series boilers are supplied completely assembled and functionally tested. • An adult person familiar with these The delivery includes: operating Instructions may only operate the boiler.
The heating system must be designed in • The pipe used in by-pass line must be at such a way that hot water can circulate all the least in the diameter of plumbing systems time through at least some of the radiators. pipe.
• On a non-flammable material overlapping the boiler footprint by 20 mm on each side and covering the entire depth of the boiler Do not put flammable materials on top of the body. boiler or near the boiler than specified safety distance.
• The effective chimney flue height measured from the point of entry of the flue pipe into the chimney. • Ensure that the calculation of the flue gas path and the connection of the flue gas system are only carried out by qualified personnel.
Page 18
Fig. 07 shows the proper flue gas connection with additional air equipment. Observe the Coefficient = 0,041 ( for wood ) following during the installation of the flue gas connection: Coefficient = 0,027 ( for carbon ) = Sections resulting (cm2) = Coefficient •...
Accumulator tank capacity NOTE: The heat can be supplied for example by an accumulator tank. The following applies as a reference for the minimum storage boiler content: : Accumulator tank capacity in L : Nominal heat output in kW : Burning period in h : Heating load of the premises in kW : Minimum heat output in kW Fig.
If a larger quantity of tar has accumulated on internal walls of the combustion chamber, it must be removed with a scraper or burnt with Warning ! hard wood (or coke), running the boiler at maximum operating temperature. • Risk of injury from carrying heavy loads! •...
• Open the ash pan door. • Remove the combustion residues from the ash pan with the ash shovel. • Do not place hot ashes in plastic and waste containers. Fig. 11 Ash pan cleaning The ashes must be removed from the combustion chamber/ash pan every 1 –...
If the air vent is closed completely, there is no complete combustion. Creosote accumulates on the heating surfaces, which requires more cleaning effort. 1. Primary air inlet 2. Secondary air inlet Fig. 13 ARTA series solid fuel boiler is designed as a three pass. Fig. 14...