Advertisement

1.

Product Overview

The ZonarSound 'Drop-in' speaker panels are flat, directional loudspeakers that have been
designed to drop into a standard 600mm x 600mm suspended ceiling grid. Each speaker
panel provides a high-quality, directional output to a specific listening zone with minimal
overspill into surrounding areas. The speaker panels are based on the flat, flexible speaker
technology developed and patented by Warwick Audio Technologies Ltd.
The speaker panels operate in a Master/Slave mode and only require an audio signal input
and power supply to the Master panel. Speaker panels can be connected in a daisy chain or
star configuration (or a combination of both). The Master speaker panel requires a low voltage
balanced or unbalanced audio input.
A separate, shelf mounted, amplifier is available as an alternative to the amplifier in the
Master panel.
ZonarSound
The Venture Centre, Sir William Lyons Road, Coventry CV4 7EZ
Tel: +44 (0) 24 7632 3287 Email: info@zonarsound.com
The ZonarSound System
Installation Manual
Ref: WAT02360213

Issue: 01

www.ZonarSound.com

Advertisement

Table of Contents
loading

Summary of Contents for ZonarSound MP600x600

  • Page 1: Issue: 01

    Installation Manual Product Overview The ZonarSound ‘Drop-in’ speaker panels are flat, directional loudspeakers that have been designed to drop into a standard 600mm x 600mm suspended ceiling grid. Each speaker panel provides a high-quality, directional output to a specific listening zone with minimal overspill into surrounding areas.
  • Page 2: Table Of Contents

    The ZonarSound System Installation Manual Issue 01 Contents 1. Product Overview 2. Important Safety Information 3. Product Configurations 3.1 Master and Slave Speaker Panels (Line Level Audio Source) 3.2 Configuration Options 3.3 DCLA 100 with Slave Speaker Panels (LL Audio Source) 4.
  • Page 3: Important Safety Information

    1. Warning! High voltages are present inside the speaker panels and DCLA100 Amplifier. 2. The ZonarSound system components must only be used with a Class II Power Supply. 3. Always disconnect the ZonarSound components from the power source before making or removing any connections.
  • Page 4: Product Configurations

    The ZonarSound System Installation Manual Issue 01 Product Configurations 3.1 Master and Slave Panels (Line Level Audio Source) 100 metres in total Maximum of 3 SPs per MP Key: 24Vdc PSU LL = Line Level (up to 3V Pk-Pk) HV = High Voltage Audio (Approx.
  • Page 5: Dcla 100 With Slave Speaker Panels (Ll Audio Source)

    The ZonarSound System Installation Manual Issue 01 3.3 DCLA 100 with Slave Panels (LL Audio Source) 100 metres in total Maximum of 4 SPs per DCLA100 24Vdc PSU Key: LL = Line Level (up to 3V Pk-Pk) Volume Audio Output...
  • Page 6: Installing Speaker Panels

    Choose a location that allows the audio signal to focus on the intended listening zone and give consideration to access to the top of the speaker panels. The speaker panels can be supported by the suspended ceiling framework, but ZonarSound recommends that additional support is provided for each panel by suspending it from the roof structure, using a recommended support system (e.g.
  • Page 7: Fitting The Speaker Panels

    • Remove the existing ceiling tile. • Replace it with the ZonarSound speaker panel, ensuring that the panel is correctly seated in the ceiling tile grid. • Use a recommended suspension system to attach the panel to the roof structure.
  • Page 8 The ZonarSound System Installation Manual Issue 01 4.3.2. Connecting Master Panel Outputs ALWAYS DISCONNECT THE POWER SOURCE BEFORE MAKING OR REMOVING ANY CONNECTIONS The inputs to the Master panel are made on the outside of the amplifier cover plate as described in section 4.3.1.
  • Page 9 The ZonarSound System Installation Manual Issue 01 4.3.3. Using an Unbalanced Audio Source Buffered LL Output to next *The LL audio output to the next Master* Master panel (where required) can be either buffered or un-buffered. Connect to the appropriate output as shown.
  • Page 10 The ZonarSound System Installation Manual Issue 01 4.3.5. Connecting the Master Panel Output to Slave Panels ALWAYS DISCONNECT THE POWER SOURCE BEFORE MAKING OR REMOVING ANY CONNECTIONS When connecting Slave panels to the Master panel, lift off the output terminal block housing and move it to a pair of output pins that corresponds with the number of Slave panels to be used.
  • Page 11 The ZonarSound System Installation Manual Issue 01 Remove the four cover retaining screws from the Slave panel and carefully lift off the cover and PCB assembly to allow access to the internal connectors. Connect the HV signal as shown below:...
  • Page 12 The ZonarSound System Installation Manual Issue 01 4.3.6. Setting the Sound Level The Master volume control for each amplifier is located on the upper face of the Master panel. Once the audio source and all panels have been powered up, the Master volume control can be...
  • Page 13: Connecting And Setting The Dcla 100 Amp Box

    The ZonarSound System Installation Manual Issue 01 Connecting and Setting the DCLA 100 AMP 5.1 Connecting the Amplifier The DCLA 100 Amplifier is used in place of a Master panel amplifier to produce the HV output required by Slave panels. The Amplifier can be placed in a location close to the audio source, and it’s HV output can drive up to four Slave panels connected in a daisy chain.
  • Page 14: Setting Up The Sound Balance

    The ZonarSound System Installation Manual Issue 01 5.2 Setting the Sound Level Pow er Ou tpu t Aud io Vo lum e Fau lt Once the audio source has been connected and the DCLA 100 has been powered, the volume control located on the front of the DCLA 100 sets the volume for all Slave panels.
  • Page 15: Declaration Of Conformity

    Of: The Venture Centre, Sir William Lyons Road, Coventry, CV5 7EZ, UK declare that: Equipment: ZonarSound ceiling tiles and amplifier Model name/numbers: MP600x600, SP600x600, DCLA 100 The following CE Marking Directives are applicable: 2006/95/EC Conforms with the safety objectives of the Low Voltage Directive and...
  • Page 16: Technical Specifications

    The ZonarSound System Installation Manual Issue 01 Technical Specifications Parameter Value Master Panel (MP600x600) and Slave Panel (SP600x600) Dimensions (mm) 595 x 595 x 30 Panel weight 5.5 kg Max SPL 90 dB @ 2 kHz @ 2 m @ 1 V RMS input.