Installation Manual Product Overview The ZonarSound ‘Drop-in’ speaker panels are flat, directional loudspeakers that have been designed to drop into a standard 600mm x 600mm suspended ceiling grid. Each speaker panel provides a high-quality, directional output to a specific listening zone with minimal overspill into surrounding areas.
1. Warning! High voltages are present inside the speaker panels and DCLA100 Amplifier. 2. The ZonarSound system components must only be used with a Class II Power Supply. 3. Always disconnect the ZonarSound components from the power source before making or removing any connections.
The ZonarSound System Installation Manual Issue 01 Product Configurations 3.1 Master and Slave Panels (Line Level Audio Source) 100 metres in total Maximum of 3 SPs per MP Key: 24Vdc PSU LL = Line Level (up to 3V Pk-Pk) HV = High Voltage Audio (Approx.
The ZonarSound System Installation Manual Issue 01 3.3 DCLA 100 with Slave Panels (LL Audio Source) 100 metres in total Maximum of 4 SPs per DCLA100 24Vdc PSU Key: LL = Line Level (up to 3V Pk-Pk) Volume Audio Output...
Choose a location that allows the audio signal to focus on the intended listening zone and give consideration to access to the top of the speaker panels. The speaker panels can be supported by the suspended ceiling framework, but ZonarSound recommends that additional support is provided for each panel by suspending it from the roof structure, using a recommended support system (e.g.
• Remove the existing ceiling tile. • Replace it with the ZonarSound speaker panel, ensuring that the panel is correctly seated in the ceiling tile grid. • Use a recommended suspension system to attach the panel to the roof structure.
Page 8
The ZonarSound System Installation Manual Issue 01 4.3.2. Connecting Master Panel Outputs ALWAYS DISCONNECT THE POWER SOURCE BEFORE MAKING OR REMOVING ANY CONNECTIONS The inputs to the Master panel are made on the outside of the amplifier cover plate as described in section 4.3.1.
Page 9
The ZonarSound System Installation Manual Issue 01 4.3.3. Using an Unbalanced Audio Source Buffered LL Output to next *The LL audio output to the next Master* Master panel (where required) can be either buffered or un-buffered. Connect to the appropriate output as shown.
Page 10
The ZonarSound System Installation Manual Issue 01 4.3.5. Connecting the Master Panel Output to Slave Panels ALWAYS DISCONNECT THE POWER SOURCE BEFORE MAKING OR REMOVING ANY CONNECTIONS When connecting Slave panels to the Master panel, lift off the output terminal block housing and move it to a pair of output pins that corresponds with the number of Slave panels to be used.
Page 11
The ZonarSound System Installation Manual Issue 01 Remove the four cover retaining screws from the Slave panel and carefully lift off the cover and PCB assembly to allow access to the internal connectors. Connect the HV signal as shown below:...
Page 12
The ZonarSound System Installation Manual Issue 01 4.3.6. Setting the Sound Level The Master volume control for each amplifier is located on the upper face of the Master panel. Once the audio source and all panels have been powered up, the Master volume control can be...
The ZonarSound System Installation Manual Issue 01 Connecting and Setting the DCLA 100 AMP 5.1 Connecting the Amplifier The DCLA 100 Amplifier is used in place of a Master panel amplifier to produce the HV output required by Slave panels. The Amplifier can be placed in a location close to the audio source, and it’s HV output can drive up to four Slave panels connected in a daisy chain.
The ZonarSound System Installation Manual Issue 01 5.2 Setting the Sound Level Pow er Ou tpu t Aud io Vo lum e Fau lt Once the audio source has been connected and the DCLA 100 has been powered, the volume control located on the front of the DCLA 100 sets the volume for all Slave panels.
Of: The Venture Centre, Sir William Lyons Road, Coventry, CV5 7EZ, UK declare that: Equipment: ZonarSound ceiling tiles and amplifier Model name/numbers: MP600x600, SP600x600, DCLA 100 The following CE Marking Directives are applicable: 2006/95/EC Conforms with the safety objectives of the Low Voltage Directive and...
The ZonarSound System Installation Manual Issue 01 Technical Specifications Parameter Value Master Panel (MP600x600) and Slave Panel (SP600x600) Dimensions (mm) 595 x 595 x 30 Panel weight 5.5 kg Max SPL 90 dB @ 2 kHz @ 2 m @ 1 V RMS input.