Dimplex 3082S Installation And Operating Instructions

Convector heaters

Advertisement

Quick Links

Dimplex Convector Heaters
Models : 3082S, 3087S, 3087ST, 3088T and 3088TA.
Dimensions
(millimetres)
Models
Specification
3082S
2.0kw Heat Switch / Thermostat / Neon / 24hr Timer
3087S
3.0kw Heat Switch / Thermostat / Neon / 24hr Timer
3087ST
3.0kw On/Off Switch / Thermostat / Neon / 24hr Timer / Turbo
3088T
3.0kw Heat Switch / Thermostat / Neon / Turbo
3088TA
3.0kw Heat Switch / Thermostat / Neon / Turbo / Ioniser
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
IMPORTANT SAFETY ADVICE
WARNING – THIS APPLIANCE MUST NOT BE USED IN A
BATHROOM.
WARNING - DO NOT USE THIS HEATER IN THE IMMEDIATE
SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING POOL.
WARNING – THIS HEATER MUST NOT BE LOCATED IMMEDIATELY
BELOW A FIXED SOCKET OUTLET.
DO NOT USE THE HEATER UNTIL THE FEET OR WALL BRACKETS
ARE FITTED CORRECTLY.
FOLLOW these instructions carefully.
NEVER cover or obstruct in any way the heat outlet slots at the top
of the heater or the air inlet slots in the base of the heater.
The heater carries a warning 'DO NOT COVER' to alert the user to the
risk of fire that exists if the heater is accidentally covered.
Timer models 3082S, 3087S and 3087ST can be set to switch on
automatically. Remember to observe all safety warnings at all times.
If young children, the aged or infirm are likely to be left in the vicinity
of the heater, we advise that adequate precautions should be taken.
We recommend that a guard be fitted to ensure contact with the
heater is avoided and objects cannot be inserted into the product.
If the mains lead is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified person in
order to avoid a hazard.
For further information, please contact our guard supplier direct on
Tel. No. 01603 667957, or in case of difficulty or for further advice
contact the Customer Helpline.
Electrical connection
WARNING – THIS APPLIANCE MUST BE EARTHED
This heater must be used on an ~ supply only and the voltage marked on
the heater must correspond to the supply voltage. This heater is fitted with
a rewireable plug incorporating a 13 amp fuse. In the event of replacing
the fuse in the plug supplied, a 13 amp fuse approved by ASTA to BS
1362 must be used. If any other type of plug is used, a 15 amp fuse must
be fitted in the plug, the adaptor, or at the distribution board.
IMPORTANT : If the plug is not suitable for your socket, the 13 amp plug
should be removed. Before wiring the appropriate plug, please note that
the wires in this mains lead are coloured in accordance with the following
code :
GREEN AND YELLOW :
BLUE :
BROWN :
Connect the GREEN AND YELLOW wire to the terminal marked 'E' or by
the earth symbol
, or coloured GREEN or GREEN AND YELLOW.
Connect the BROWN wire to the terminal marked 'L' or coloured RED.
Connect the BLUE wire to the terminal marked 'N' or coloured BLACK
EARTH
NEUTRAL
LIVE
Installation and Operating Instructions
230
777 - 3.0kw
657 - 2.0kw
MIN
432
Wall Mounting
Three identical wall mounting brackets are secured to the base of the
heater with a fixing screw. To wall mount appliance, first remove the
brackets as follows :
Lay the heater on its back.
Following the sequence in Fig. 1 – identify and remove the fixing screw
securing the brackets located beside Mains Cable as shown in (a), then
pull out brackets and rotate them to disengage them from the slot (b).
Withdraw the brackets from the slot (c).
(a)
Select a suitable position on a wall, near to a mains power socket,
making sure that there is at least 230 mm below the heater and at least
450 mm above the heater of unobstructed space. See also 'Positioning
the heater'.
Fix the two top retaining brackets to the wall, using suitable fixings, for
2kw models at 358 mm centres and 3kw models at 478 mm centres –
see Fig 2.
Locate the heater on the top brackets and allow it to hang in place.
Fit the bottom bracket into the slot in the heater and then fix it to the wall.
Test that the heater is now securely fixed to the wall.
INDCUK308R
Issue 6
450
MIN
230
140
MIN
357
230
MIN
Floor Mtd.
Wall Mtd.
.
(b)
(c)
Fig. 1
Fig. 2

Advertisement

loading

Summary of Contents for Dimplex 3082S

  • Page 1 The heater carries a warning ‘DO NOT COVER’ to alert the user to the risk of fire that exists if the heater is accidentally covered. Timer models 3082S, 3087S and 3087ST can be set to switch on automatically. Remember to observe all safety warnings at all times.
  • Page 2 Heat selection is available on all models as an economy feature. Always ensure that the heater is stood on a firm, level base near to, but On models 3082S and 3087S - the switch is a 2 position switch with two not directly beneath, a suitable mains supply socket.
  • Page 3 Summertime Function Once the timer batteries are fully charged , if there is either a power cut or if the heater is disconnected from the mains for less than 100 hours , Summertime function is very useful for areas with summertime system , then the timer will continue to keep time &...
  • Page 4 Hampshire. SO30 2DF Republic of Ireland Tel. 01 8424833 [c] Glen Dimplex UK Limited All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex UK Limited.