Antik MX5308 User Manual

Professional 8-in-1 ts processor

Advertisement

Quick Links

Professional 8-in-1 TS Processor
MX5308
USER MANUAL
2015/06

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MX5308 and is the answer not in the manual?

Questions and answers

Summary of Contents for Antik MX5308

  • Page 1 Professional 8-in-1 TS Processor MX5308 USER MANUAL 2015/06...
  • Page 2 MX5308 8-in-1 TS Processor License Declaration Without the prior written permission of ANTIK Technology, no part of this manual shall be added or removed in any form, adaptation, excerpt, translate, reproduce or imitation. The entire contents of this manual may be changed by ANTIK Technology at any time without prior notice.
  • Page 3: Table Of Contents

    Your digital visual world! Contents OVERVIEW FEATURES TECHNICAL SPECIFICATIONS FRONT PANEL AND REAR PANEL INSTRUCTIONS Front Panel Rear Panel RS-232 Serial Port Management Ethernet Port TS over IP Ethernet Port OPERATION Local Control 5.1.1 Getting Started 5.1.2 Main Menu 5.1.3 Configuration Menu 5.1.4 System Menu...
  • Page 4 ATSC types. It supports a wide range of application by combining 8 tuners processing capability with industry standard outputs including ASI and TS/IP. MX5308 has 8 DVB common interface slots capable of working with most of well-known CAS in the market to de-crypt multiple pay TV services.
  • Page 5 Your digital visual world! Your digital visual world! TECHNICAL SPECIFICATIONS Tuner Input DVB-S/S2 Tuner Input (ISI Factory Optional) Connector Type 8×F type female 75Ω for Input Input Frequency Range 950 ~ 2150MHz Input Level -25 ~ -65dBm Symbol Rate 2 ~ 45MBaud DVB-S QPSK: 0.35 Roll-off Factor DVB-S2 8PSK: 0.35, 0.25, 0.2...
  • Page 6 MX5308 8-in-1 TS Processor Constellation 4QAM-NR,4QAM,16QAM,32QAM,64QAM Guard Interval PN420, PN595, PN945 Roll-off Factor 0.05 Interleaving Depth 240,720 FEC Code Rate 0.4, 0.6, 0.8 ATSC Tuner Input(compatible with ITU J.83 Annex B) Connector Type 8×F type female 75Ω for Input Input Frequency Range...
  • Page 7 Your digital visual world! Control & Monitoring Connector Type 1×RJ-45, 10/100 Base-T, for equipment IP Control Remote Control SNMP, HTTP (Web Interface), Proprietary HDMS (Headend Device Management System) Local Control LCD display and 6-key keypad Serial Port 1×RS-232 D-sub female, for debug use only Equipment Upgrade USB,WEB http and FTP Physical...
  • Page 8: 1 Overview

    MX5308 8-in-1 TS Processor OVERVIEW 4.1 FRONT PANEL Name Function When turned on, the Green LED indicates that power is available. When LED Power turned off, the power is not available or failed LED ON: LED Warning LED OFF: LED ON: Alarm or alarms happen to the equipment, For alarm description, LED Alarm please refer to details in the table 10.
  • Page 9: Rs-232 Serial Port

    Both web based control software and proprietary HDMS software are using this port. Notice: When apply default setting to MX5308, the above settings for IP will not be affected, this is for maintaining the connectivity of the unit to the IP Network.
  • Page 10: Ts Over Ip Ethernet Port

    MX5308 8-in-1 TS Processor 4.5 TS OVER IP ETHERNET PORT The TS over IP port is an option by adding the daughter board inside the rack. The default setting is as following: l IP address:10.10.10.10 l 2 IP address: 10.10.10.20 l Sub Mask:255.255.255.0...
  • Page 11: Local Control

    CONTROL 5.1.1 Getting Started After successful installation and connection of the Professional IRD Processor MX5308, switch on the power supply. The equipment will check the hardware and software versions, then the product name and its IP address will be shown in the LCD screen.
  • Page 12: Configuration Menu

    MX5308 8-in-1 TS Processor ● Status ● Config ● System After go into every sub-menu, you can press LEFT or RIGHT to move the cursor, then use UP or DOWN to change the value, and then you can press ENTER to make the selection.
  • Page 13: System Menu

    Your digital visual world! CI CAM Name To check what kind of CAMs have been inserted. CI Setup To set which programs should be descrambled by CI-1(~8) CI slot1 or CI slot2. BISS Mode To select the BISS mode, user can choose between Off, BISS-1 and BISS-E.
  • Page 14: Remote Control (Web)

    5.2 REMOTE CONTROL (WEB) MX5308 can be controlled by WEB. User can type IP address of MX5308 in browser. It will show login pop-up. The default user name is root and password is 12345. If you forget this username and password, you can use front panel button to change it.
  • Page 15: Configuration

    Your digital visual world! Tuner Status—User can Tuner signal status here. TS/IP Status—User can TS over IP status here. 5.2.2 Configuration Set parameters of tuner input, CI, Biss and ASI Output. www.antiktech.com...
  • Page 16: Configuration-Tuner

    MX5308 8-in-1 TS Processor 5.2.2.1 Configuration-Tuner Tuner(1~8) It is used to lock the right satellite. The description of parameters is shown in below. Click “Apply” button to submit, or click “Cancel” button to cancel. Menu Name Description To configure the local oscillator frequency according to the right satellite, its...
  • Page 17: Configuration-Cl

    Click “Apply” button to submit, or click “Cancel” button to cancel. 5.2.2.3 Configuration-Biss Biss (1~8) Set parameters of BISS Descryption. MX5308 supports BISS-1 and BISS-E mode. Click “Apply” button to submit, or click “Cancel” button to cancel. www.antiktech.com...
  • Page 18: Configuration-Asi Output

    MX5308 8-in-1 TS Processor Menu Name Description To select the correct BISS mode, user can choose between BISS- BISS Mode 0, BISS-1 and BISS-E. Input Key value in BISS-1 mode and input ID and Key in BISS-E ID and Key mode.
  • Page 19: Remux

    Your digital visual world! 5.2.3 Remux Set parameters of programs remuxing. The Remux function is a optional function, you can active or close this option in the System page. In this page, all programs can be shown in the Input TS window, you can select the programs that need to be remuxed, and then type button to add the programs into the Output TS window.
  • Page 20: Ts/Ip

    MX5308 8-in-1 TS Processor 5.2.4 TS/IP TS over IP function is also an optional function, you can select the IP board type in this page. TS/IP page will show Gigabit Out, Gigabit In and Gigabit Local (Gigabit Mode-Multiple Output only).
  • Page 21: Gigabit Out

    Your digital visual world! 5.2.4.2 Gigabit Out Gigabit Out is selected, the following page will be shown. Click “Apply” button to submit, or click “Cancel” button to cancel. www.antiktech.com...
  • Page 22: Gigabit In

    MX5308 8-in-1 TS Processor 5.2.4.3 Gigabit In Gigabit In is selected, the following page no information (Gigabit Mode-Multiple Output only). 5.2.5 System Set parameters of system. There are three subpages, Device page, IP Control Page, Version page, Login Page, Factory Default page, System Reboot and Upgrade page.
  • Page 23 Your digital visual world! In Network Setting page, user can set the network management parameters and the MAC will be shown. Click “Apply” button to submit, or click “Cancel” button to cancel. www.antiktech.com...
  • Page 24 8-in-1 TS Processor In Version page, user can read the software version. In Web Login page, user can set your own username and password to access webGUI of MX5308. In Factory Default page, user can restore factory default configuration of MX5308. www.antiktech.com...
  • Page 25 Your digital visual world! In System Reboot page, user can reboot MX5308. www.antiktech.com...
  • Page 26: Firmware Update

    MX5308 8-in-1 TS Processor FIRMWARE UPDATE Before upgrading the digital TV head-end equipment, please check whether the Hardware and Software are compliant with the version in the release note. 6.1 FIRMWARE UPGRADE FROM USB KEY The firmware is contained in a file named “target.tgz”. Copy this file in a USB key, connect the key to the USB port of the equipment to be updated.
  • Page 27 Your digital visual world! Open the IE browser and type ftp://10.10.70.48 in the address bar and press Enter. If the network configuration is correct, you can open the FTP folder without any error, as shown below. Figure 2: Open the FTP folder Enter the “ftp://10.10.70.48/pub”...
  • Page 28 MX5308 8-in-1 TS Processor Figure 4: Open MS-DOS Window Type Enter to go into the login window. Use “root” as login name and “12345” as password. Figure 5: Login Menu Key in the command “upgrade” and press Enter. The upgrade process will be launched.
  • Page 29: Firmware Update From Web

    Your digital visual world! Figure 6: Upgrading When the upgrade is finished, the equipment will reboot automatically. Check the new version through “LCD: System->Properties”, or from web control page. 6.3 FIRMWARE UPGRADE FROM WEB Open the Web control page of the equipment. Go to the “upgrade” function in the SYSTEM menu. Browse the file named “Target.tgz”, click Upload file button, then the firmware is automatically uploaded in the memory of the equipment.
  • Page 30: Installation

    MX5308 8-in-1 TS Processor INSTALLATION l Fix the device in the standard 19” rack. l Connect the power cable. Turn on the device and wait for 8 to 10 seconds, while the device will complete self inspection and configuration. The POWER Indicator LED will always light on during working.
  • Page 31 Do not remove the covers of this equipment. Hazardous voltages are present within this equipment and may be exposed if the covers are removed. Only ANTIK Technology trained and approved service engineers are permitted to service this equipment.
  • Page 32 ANTIK Technology http://www.antiktech.com Address: Čárskeho 10, SK-04001 Košice, Slovakia Tel: +421-55-3012345 Web: www.antiktech.com Email: info@antiktech.com June 2015...

Table of Contents