Download Print this page

SBI AC02582 Operating Instructions Manual page 3

Ash vacuum

Advertisement

Available languages

Available languages

Model #:
Voltage
Frequency
Power
Max Vacuum
ASH
Sound Level Max
VACUUM
Max Airfl ow
INSTRUCTIONS FOR USE
IMPORTANT NOTES:
*
Each use, verify that HEPA fi lter is in place and that HEPA seal plate
wing nut is tight. Always test seal by vacuuming up a small amount of
ash while located away from living areas
** Do not attempt to use vac to remove large piles of ash from a fi replace
or wood stove. Instead remove bulk of ash with a shovel and ash can
(or hod) and then use the ash vac for fi nal cleanup.
1. Plug cord into outlet, (see photo 1 bellow).
2. Press the on/off button to switch the appliance on (see photo
2 bellow).
3. For fi replaces and wood burning stoves see "important
note **", above. Place nozzle in fi rebox. Keep nozzle pressed
against the fl at surfaces of stove or fi replace to limit entrance
of large chunks into pickup tube. Use the built-in vibrating
fi lter cleaning feature after approximately each 1 cup of ash
is removed or when suction is reduced. Shaker instructions
are below. If large chunks are picked up, turn off machine to
dislodge.
1
HOW TO USE THE BUILT-IN VIBRATING FILTER CLEANING
FEATURE
When the suction is reduced or after about 1 cup of ash has been
removed use the vibration knob to help remove ash from fi lter
without taking off the lid.
A. Turn off machine!
B. Hold can down and retract shake off knob fully.
C. Release so knob bangs top lid.
D. This will send vibrations through the top lid to the fi lter to
help clear debris. Repeat 5 to 10 times. Suction should now
improve at star-tup.
A
4. When fi nished cleaning turn switch off , photo (see photo 4
following) .
5. Remove the plug from the outlet (see 5 following) and take
vacuum to an outside location away from valuables and
breezes.
AC02582
120 V
60 Hz
800 W
17 Kpa
<84 dB
85-CFM
2
B
C
6. Release the fl exible hose from the air intake duct. A Small
amount of ash may be generated so be carefull (see 6
following).
4
7. Verify ash is cold! Allow to cool further if needed, then dump
debris. Ash is a great garden supplement!
8. Every 3 to 5 uses, clean HEPA fi lter while outside and away
from valuables. Screw off the fi lter wing nut and HEPA seal
plate (not shown). Take the fi lter out for cleaning (see step
below) or change. Follow the three steps below for taking off
the fi lter.
NOTE: This process will be dusty. Pictures depict a clean machine
for illustrative purposes.
9. Cleaning fi lter - to limit dust place HEPA fi lter inside a plastic
bag (not included). To clean fi lter, tap gently against a hard
surface. Empty plastic bag and inspect fi lter. Dust within
the fi lter pleats may require gentle fl exing of the fi lter by
squeezing the fi lter's rubber seals so as to make the fi lter oval
instead of round. Tap fi lter while "Out of round" to get deeply
set dust out of pleats.
Follow steps below for re-assembly of the fi lter :
3
10. IMPORTANT - with fi lter installed and lid in place turn
vacuum on at a dry outside location to test fi lter seal. Look
for dust at the exhaust port. A small amount is normal after
cleaning fi lter. Vacuum up a small amount of ash while still
outside to give fi nal assurance of a good seal and to verify
fi lter integrity. Replace fi lter if dust passes though at this point.
SootStop Pre-fi lter extends the life of HEPA fi lter. Most helpful
with pellets stoves.
D
FILTER CARE: Filter may be washed or simply shaken out. Replace
if holes in fabric develop.
5
LOOSEN
WING NUT
TIGHTEN
WING NUT
INSTALLATION - Start with a new
or cleaned HEPA fi lter, seal plate
and wing nut .Place elastic over
the seal plate and pull down.
Pull SootStop fi lter fully so the
elastic contacts the rubber part.
6
3

Advertisement

loading