To get the most efficient
use from
your new dryer, read your Use and
Care Guide.
Keep Installation
Instructions
and Guide
close to the
dryer for easy reference.
Recessed and
closet installation
in!structions
The dryer may be installed
in a recessed
area or closet.
If the dryer is installed
in a closet, the
dryer MUST be exhausted
outside
Failure to do so may result in a fire.
To prevent
large amounts
of lint and
moisture from accumulating,
to maintain
drying efficiency
and to prevent
exposure
to possible
health hazards, this
dryer MUST be exhausted
outdoors.
The installation
spacing
is in inches and
centimeters
and is minimum
allowable.
Additional
spacing
should be
considered
for ease of installation,
servicing
and compliance
with local
codes and ordinances.
Closet door must have minimum
air
openings
for adequate
air flow.
Louvered
doors with equivalent
air
openings
are acceptable.
(See
diagrams
at right.) Other installations
must use the minimum
dimensions
indicated.
Companion
appliance
spacing
should be considered.
For recessed,
non-exhausted
installation,
Exhaust Deflector
Kit, Part No. 346001, is
required.
recessed
front view
L LL 0 0
l&.7
cm)
T
4-
0"' (0 cm)
Minimum installation spacing
Closet installation
must be exhausted.
side view
closet door
\
14" max
(35.7 cm,
p**
(10.2 cm)
front view
closet door
7-l
4
48
sq. in.**
(310 sq. cm)-
t
24 sq. in.**
(155 sq. cm)-
t
* Additional
clearances
for wall, door
and floor moldings
may be required.
l
* Opening
is minimum
for closet door.
Louvered
door with equivalent
air
openings
is acceptable.
l
**
Additional
space
is needed
when
external
exhaust
elbow
is used.
Page 10