Download Print this page

Whirlpool AWM 312 Service Manual page 3

Washing machine frontloader

Advertisement

S E R V I C E
Technical data
Inlet valve hot
Water temperaturemax.
Rated flow
< 1 bar 4
Pressure range
Nominal voltage
Frequency
Starting voltage
< 6 bar 160
6-10 bar170
Nominal current
Nominal power
Nominal resistor
( 20˚C ) 4060
Program timer
Typ
Hybridtimer with integrated
electronic
Fab.
Eaton EC 4475 (Timer 2b)
Nominal voltage
Frequency
Total positions
Positions
Pre wash
Main wash
Rinse
Spin
Safety position
Stop
Motor
Typ
MCA 52/64 - 148 t.f./ WHE0
i = 1 : 13,5
Resistance contacts
Whirlpool Europe
Customer Service
90
˚C
l/min.
0,5-10 bar
220-240V
50
Hz
V
V
35
mA
6
VA
230
V
50
Hz
60
pos.
01 - 09
pos.
10 - 31
pos.
32 - 49
pos.
50 - 55
pos.
56 - 58
pos.
59 - 60
68,70Ω ± 7%
6 - 7
2,15 Ω ± 7%
4 - 5
1,46 Ω ± 7%
2 - 3
0,65 Ω ± 7%
1 - 3
AWM 312
8570 312 53000
Radio interference supression
Condensator
Nominal voltage
Nominal capacity
Nominal inductances
Nominal resistance
Temperature selector switch
Positions
Nominal voltage
Value of resistors
1-2-3
4-6
5-6
Switch rotary spin speed
Positions
Nominal voltage
Value of resistors
1-2-3
4-6
5-6
Push botton switch
Start stop
Rinse hold
Pre wash
Eco
Rapid
Half load
Intensive rinse
26.06.1997 / Page 3
Doc. No: 4812 712 12529
FribourgFA 26
230
V
0,47µ FX2+2x0,022nFY
2 x 470 mH
680
mΩ
7
5
V
internal shunt
internal shunt
Pos. 1 0 Ω
Pos. 2 0,68 kΩ± 5%
Pos. 3 1,10 kΩ± 5%
Pos. 4 1,80 kΩ± 5%
Pos. 5 2,70 kΩ± 5%
Pos. 6 3,60 kΩ± 5%
Pos. 7 4,70 kΩ± 5%
7
5
V
internal shunt
internal shunt
Pos. 1 0 Ω
Pos. 2 0,68 kΩ± 5%
Pos. 3 1,10 kΩ± 5%
Pos. 4 1,80 kΩ± 5%
Pos. 5 2,70 kΩ± 5%
Pos. 6 3,60 kΩ± 5%
Pos. 7 4,70 kΩ± 5%
SST
SRS
SPW
SEC
SR
SHL
SRI

Hide quick links:

Advertisement

loading