LED and Button Descriptions
Ethernet port
Item
Description
Power
• Solid green. The electrical power is on.
LED
• Blinking green. The adapter is in the process of restarting or setting up security.
• Off. There is no electrical power.
Powerline
• Solid green. The adapter is connected to a Powerline network.
LED
• Off. The adapter has not found any other compatible Powerline devices using
the same encryption key.
The Pick A Plug feature lets you pick the electrical outlet with the strongest link
rate, indicated by the LED color:
Green:
Amber:
Link rate > 80 Mbps
Link rate > 50 and < 80 Mbps
(Best)
(Better)
Item
Description
Power LED
Ethernet
• Solid green. The Ethernet port is linked, and/or data is being transmitted.
LED
• Off. There is no Ethernet connection.
Ethernet LED
Powerline LED
Factory
Press the Factory Reset button for 1 second, then release to return the Powerline
Reset
adapter to its factory default settings.
Security
After you plug in your new AV adapter, press the Security button for 2 seconds,
button
then press the Security button on one of the other AV adapters in your existing
Security
network for 2 seconds. Both buttons must be pressed within 2 minutes.
Note:
The Security button does not work in power saving mode, during which
Factory Reset
the Power LED blinks once every 3 seconds.
Filtered
The filtered AC socket can remove some electrical noise which can affect Power-
AC Socket
line performance. Plugging the power plugs of nearby devices into the filtered
AC socket may improve performance.
Warning: Do not press the Security/Power button on the Powerline adapter until installation is
complete and the adapters are communicating with each other (indicated by the blinking
Powerline LED). Pressing this button too soon can temporarily disable Powerline communication. If
this should occur, use the Factory Reset button to return the Powerline adapter to its factory
default settings.

Important Safety Information

AC input:100-125V~, 0.1A (Max;NA) and 200-250V~, 0.1A (Max;others),
for product only.
Operating temperature: 0C~40C
The socket-outlet should be installed near the equipment and be easily
accessible.
XAV1601 ratings (maximum load):
Red:
Link rate < 50 Mbps
-- EU: 16A 250V~
(Good)
This symbol was placed in accordance with the European Union Directive 2002/96 on the Waste
Electrical and Electronic Equipment (the WEEE Directive). If disposed of within the European Union,
this product should be treated and recycled in accordance with the laws of your jurisdiction
June 2012
implementing the WEEE Directive.
-- UK: 13A 250V~
– NA: 15A 125V~
Only power cords are allowed to be inserted into the filtered AC outlet; no other
equipment with a direct plug-in is allowed. Power cord needs to be a maximum
of 1m long and a minimum of 0.75mm square of cross-sectional area.
Do not plug devices into the XAV1601 filtered AC outlet that exceed the product
ratings.The output voltage of the filtered AC outlet is the same as the power
outlet into which the XAV1601 is plugged. To help avoid damaging your system,
be sure that the attached devices are electrically rated to operate with the power
available in your location.
If the input AC voltage is less than 125Vac, the device plugged into the filtered
AC socket of the XAV1601 may not perform as well as expected.
DO NOT PLUG MAJOR HOME APPLIANCES into the filtered AC socket or into
an attached powerstrip. The device is not intended to be used with home
appliances such as air conditioners, powertools, space heaters, fans, hair
dryers, ovens, or refrigerators.
Check the electrical current for any appliance used with the device, and do not
exceed home and product outlet ratings and electrical requirements.

Technical Support

Thank you for selecting NETGEAR products.
After installing your device, locate the serial number on the label of your product and
use it to register your product at http://www.NETGEAR.com/register. Registration is
required before you can use our telephone support service. Registration via our
website is strongly recommended.
To access the XAV1601 utility, for product updates, and for Web support, go to
http://support.netgear.com.
GPL may be included in this product; to view the GPL license agreement, go to:
ftp://downloads.netgear.com/files/GPLnotice.pdf.
For complete DoC, visit the NETGEAR EU Declarations of Conformity website at:
http://support.netgear.com/app/answers/detail/a_id/11621.
NETGEAR, the NETGEAR logo, and Connect with Innovation are trademarks and/or registered trademarks of
NETGEAR, Inc. and/or its subsidiaries in the United States and/or other countries. Information is subject to change
without notice. Other brand and product names are trademarks or registered trademarks of their respective holders.
© 2012 NETGEAR, Inc. All rights reserved.

Advertisement

loading