Manuals and User Guides for Endress+Hauser Proline Prosonic Flow 91. We have
2
Endress+Hauser Proline Prosonic Flow 91 manuals available for free PDF download: Operating Instructions Manual
Endress+Hauser Proline Prosonic Flow 91 Operating Instructions Manual (118 pages)
Ultrasonic Flow Measuring System
Brand:
Endress+Hauser
| Category:
Measuring Instruments
| Size: 1.8 MB
Table of Contents
Table of Contents
3
Safety Instructions
5
Designated Use
5
Installation, Commissioning, Operation
5
Operational Safety
5
Return
6
Notes on Safety Conventions and Icons
6
Identification
7
Device Designation
7
Nameplate of the Transmitter
7
Nameplate of the Sensor
8
Nameplate of the Connections
8
Certificates and Approvals
9
Registered Trademarks
9
Installation
10
Incoming Acceptance, Transport and Storage
10
Incoming Acceptance
10
Transport
10
Storage
10
Installation Conditions
11
Installation Dimensions
11
Mounting Location
11
Orientation
12
Inlet and Outlet Runs
12
Sensor Selection and Arrangement
13
Preparatory Steps Prior to Installation
14
Determining the Necessary Installation Distances
14
Clamp-On
14
Determining Values for Installation Distances
14
Mechanical Preparation
15
Mounting the Sensor Holder with
15
U-Shaped Screws (Small Nominal Diameters)
15
Mounting the Sensor Holder with Strapping
16
Bands (Small Nominal Diameters)
16
Premounting the Strapping Bands (Medium Nominal Diameters)
17
Premounting the Strapping Bands (Large Nominal Diameters)
18
Installing Prosonic Flow W Sensor
19
Installing Prosonic Flow W
19
(DN 15 to 65 / ½ to 2½")
19
Installing Prosonic Flow W (DN 50 to 4000 / 2" to 160")
21
Mounting the Transmitter
26
Post-Installation Check
26
Wiring
27
Connecting and Grounding Prosonic Flow W (DN 50 to 4000 / 2 to 160") Two Single Coaxial Cables
27
Connecting Prosonic Flow W
27
Connecting and Grounding Prosonic Flow W
28
DN 15 to 65 (½ to 2½") Multicore Cable
28
Cable Specifications
29
Connecting the Measuring Unit
30
Transmitter
30
Terminal Assignment
31
HART Connection
31
Potential Equalization
32
Degree of Protection
32
Post-Connection Check
33
Operation
34
Display and Operating Elements
34
Brief Guide to the Function Matrix
35
General Notes
36
Enabling the Programming Mode
36
Disabling the Programming Mode
36
Communication
37
Operating Options
37
Device Description Files for Operating Programs
38
Device Variables
38
HART Commands
39
Device Status/Diagnosis Messages
44
Commissioning
45
Function Check
45
Switching on the Measuring Device
45
Commissioning Via a Configuration Program
46
Sensor Setup/Sensor Installation
46
Commissioning
47
Data Backup/Transmission
48
Application Specific Commissioning
49
Zero Point Adjustment
49
Data Storage Devices
50
Historom/T-DAT (Transmitter DAT)
50
Maintenance
51
Exterior Cleaning
51
Coupling Fluid
51
Accessories
52
Device-Specific Accessories
52
Accessories Specific to Measuring Principle
52
Communication-Specific Accessories
53
Service-Specific Accessories
54
Troubleshooting
55
Troubleshooting Instructions
55
Diagnosis Code Messages
56
Category F Diagnosis Code Messages
56
Category C Diagnosis Code Messages
57
Category S Diagnosis Code Messages
58
Process Errors Without Messages
59
Response of Outputs to Errors
60
Spare Parts
61
Removing and Installing Electronics Boards
62
Field Housing: Removing and Installing Electronics Boards Å 41
62
Replacing the Device Fuse
64
Return
65
Disposal
65
Software History
65
Technical Data
66
Technical Data at a Glance
66
Application
66
Function and System Design
66
Input
66
Output
67
Power Supply
67
Performance Characteristics
70
Operating Conditions: Installation
71
Operating Conditions: Environment
72
Operating Conditions: Process
72
Mechanical Construction
73
Human Interface
73
Certificates and Approvals
74
Ordering Information
74
Accessories
74
Documentation
74
Description of Device Functions
75
Illustration of the Function Matrix
75
Group MEASURING VALUES
77
Group SENSOR SETUP
78
Group SYSTEM UNITS
79
Group OPERATION
81
Group USER INTERFACE
83
Group TOTALIZER
84
Group CURRENT OUTPUT
85
Group PULSE/STATUS OUTPUT
87
Information on the Response of the Status Output
90
Switching Behavior of the Status Output
91
10.10 Group COMMUNICATION
92
10.11 Group PROCESS PARAMETER
93
10.12 Group PIPE DATA
95
10.13 Group LINER
98
10.14 Group LIQUID DATA
99
10.15 Group CONFIG. CHANNEL
102
10.16 Group CALIBRATION DATA
104
10.17 Group SYSTEM PARAMETER
105
10.18 Group SUPERVISION
109
10.19 Group SIMULATION SYSTEM
111
10.20 Group SENSOR VERSION
112
10.21 Group AMPLIFIER VERSION
112
10.22 Factory Settings
113
10.22.1 si Units
113
Units (for USA and Canada Only)
113
Advertisement
Endress+Hauser Proline Prosonic Flow 91 Operating Instructions Manual (108 pages)
Ultrasonic Flow Measuring System
Brand:
Endress+Hauser
| Category:
Measuring Instruments
| Size: 1.56 MB
Table of Contents
Table of Contents
3
Safety Instructions
5
Designated Use
5
Installation, Commissioning, Operation
5
Operational Safety
5
Return
6
Notes on Safety Conventions and Icons
6
Identification
7
Device Designation
7
Nameplate of the Transmitter
7
Nameplate of the Sensor
8
Nameplate of the Connections
8
Certificates and Approvals
9
Registered Trademarks
9
Installation
10
Incoming Acceptance, Transport and Storage
10
Incoming Acceptance
10
Transport
10
Storage
10
Installation Conditions
11
Installation Dimensions
11
Mounting Location
11
Orientation
12
Inlet and Outlet Runs
12
Sensor Selection and Arrangement
13
Installation Instructions
14
Installing Tensioning Bands
14
Installation for Measurement
15
Via One Traverse
15
Via Two Traverses
18
Affixing the Local Display to the
20
Blind Version
20
Rotating the Local Display
20
Mounting the Transmitter
21
Post-Installation Check
21
Wiring
22
Connecting the Sensor Connecting Cables
22
Connecting Prosonic Flow W
22
Cable Specifications
23
Connecting the Measuring Unit
24
Transmitter
24
Terminal Assignment
25
HART Connection
25
Potential Equalization
26
Degree of Protection
26
Post-Connection Check
27
Operation
28
Display and Operating Elements
28
Brief Guide to the Function Matrix
29
General Notes
30
Enabling the Programming Mode
30
Disabling the Programming Mode
30
Communication
31
Operating Options
31
Device Description Files for Operating Programs
32
Device Variables
32
HART Commands
33
Device Status/Diagnosis Messages
38
Commissioning
39
Function Check
39
Switching on the Measuring Device
39
Commissioning Via a Configuration Program
40
Sensor Setup/Sensor Installation
40
Commissioning
41
Data Backup/Transmission
42
Application Specific Commissioning
43
Zero Point Adjustment
43
Data Storage Devices
44
Historom/T-DAT (Transmitter DAT)
44
Maintenance
45
Exterior Cleaning
45
Coupling Fluid
45
Accessories
46
Device-Specific Accessories
46
Accessories Specific to Measuring Principle
46
Communication-Specific Accessories
47
Service-Specific Accessories
48
Troubleshooting
49
Troubleshooting Instructions
49
Diagnosis Code Messages
50
Category F Diagnosis Code Messages
50
Category C Diagnosis Code Messages
51
Category S Diagnosis Code Messages
52
Process Errors Without Messages
53
Response of Outputs to Errors
54
Spare Parts
55
Removing and Installing Electronics Boards
56
Field Housing: Removing and Installing Electronics Boards
56
Replacing the Device Fuse
58
Return
59
Disposal
59
Software History
59
Technical Data
60
Technical Data at a Glance
60
Application
60
Function and System Design
60
Input
60
Output
61
Power Supply
61
Performance Characteristics
62
Operating Conditions: Installation
63
Operating Conditions: Environment
64
Operating Conditions: Process
64
Mechanical Construction
65
Human Interface
65
Certificates and Approvals
66
Ordering Information
66
Accessories
66
Documentation
66
Description of Device Functions
67
Illustration of the Function Matrix
67
Group MEASURING VALUES
69
Group SENSOR SETUP
70
Group SYSTEM UNITS
71
Group OPERATION
73
Group USER INTERFACE
75
Group TOTALIZER
76
Group CURRENT OUTPUT
77
Group PULSE/STATUS OUTPUT
79
Information on the Response of the Status Output
82
Switching Behavior of the Status Output
83
Group COMMUNICATION
84
Group PROCESS PARAMETER
85
Group PIPE DATA
87
Group LINER
89
Group LIQUID DATA
90
Group CONFIG. CHANNEL
93
Group CALIBRATION DATA
95
Group SYSTEM PARAMETER
96
Group SUPERVISION
99
Group SIMULATION SYSTEM
101
Group SENSOR VERSION
102
Group AMPLIFIER VERSION
102
Factory Settings
103
Units
103
Units (for USA and Canada Only)
103
Language
103
Index
104
Advertisement
Related Products
Endress+Hauser Proline Prosonic Flow 93
Endress+Hauser prosonic flow 92
Endress+Hauser Prosonic Flow 300
Endress+Hauser Prosonic Flow 400
Endress+Hauser Prosonic Flow 500
Endress+Hauser micropilot M FMR 230
Endress+Hauser Waterpilot FMX167
Endress+Hauser Proline Promass F 500
Endress+Hauser Nivocompact FTC 131
Endress+Hauser Prosonic FDU80F
Endress+Hauser Categories
Measuring Instruments
Transmitter
Radar
Switch
Accessories
More Endress+Hauser Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL