Manuals and User Guides for Bryant 551J*08D/K Series. We have
1
Bryant 551J*08D/K Series manual available for free PDF download: Installation Instructions Manual
Bryant 551J*08D/K Series Installation Instructions Manual (56 pages)
SINGLE PACKAGE ROOFTOP COOLING ONLY SIZES 07, 08, 09, 11 AND 12 WITH PURONR (R--410A) REFRIGERANT
Brand:
Bryant
| Category:
Heat Pump
| Size: 5.3 MB
Table of Contents
Table of Contents
1
Theinstallation.
2
Safety Considerations
2
Rated Indoor Airflow (Cfm)
3
Installation
8
Jobsite Survey
8
Step 1 - Plan for Unit Location
8
Roof Mount
8
Step 2 - Plan for Sequence of Unit Installation
8
Curb- - Mounted Installation
9
Pad- - Mounted Installation
9
Frame- - Mounted Installation
9
Step 3 - Inspect Unit
9
Step 4 - Provide Unit Support
9
Roof Curb Mount
9
Slab Mount (Horizontal Units Only)
9
Alternate Unit Support (in Lieu of Curb or Slab Mount)
11
Step 5 - Field Fabricate Ductwork
11
For Units with Accessory Electric Heaters
11
Step 6 - Rig and Place Unit
11
Positioning on Curb
12
Step 7 - Convert to Horizontal and Connect
12
Ductwork
12
Step 8 - Install Outside Air Hood
13
Economizer and Two Position Damper Hood Package Removal and Setup - Factory Option
13
Economizer Hood and Two- - Position Hood
13
Step 9 - Install External Condensate Trap and Line
14
Step 10 - Make Electrical Connections
14
Field Power Supply
14
Units with Factory- - Installed Non- - Fused Disconnect
15
Non- - Fused Disconnect
15
Units Without Factory- - Installed
16
Non- - Fused Disconnect
16
All Units
16
Convenience Outlets
17
Factory Option Thru- - Base Connections
18
Units Without Thru- - Base Connections
18
Field Control Wiring
18
Thermostat
18
Central Terminal Board
19
Unit Without Thru- - Base Connection Kit
19
Heat Anticipator Settings
19
Electric Heaters
19
Single Point Boxes and Supplementary Fuses
20
Single Point Boxes Without Fuses
20
Low- - Voltage Control Connections
21
Low Ambient Control (Factory Option)
21
Variable Frequency Drive (VFD) 2- - Speed Indoor Fan Motor System (Factory- - Installed)
21
Perfect Humidityt System Control Connections
21
Perfect Humidity System - - Space RH Controller
21
Economi$Er R X (Factory- -Installed Option)
23
Product Description
23
System Components
23
Specifications
23
W7220 Economizer Module
23
Electrical
23
Inputs
23
Outputs
24
Environmental
24
Economizer Module Wiring Details
24
S- - Bus Sensor Wiring
24
CO 2 Sensor Wiring
25
Interface Overview
25
User Interface
25
Keypad
25
Menu Structure
26
Setup and Configuration
26
Time- - out and Screensaver
26
Sequence of Operation
32
Enthalpy Settings
35
Two- -Speed Fan Operation
35
Checkout
36
Power up
36
Initial Menu Display
36
Power Loss (Outage or Brownout)
37
Status
37
Checkout Tests
37
Troubleshooting
37
Alarms
37
RTU Open Controller System
38
Supply Air Temperature (SAT) Sensor
41
Outdoor Air Temperature (OAT) Sensor
41
Economi$Er R 2
42
Field Connections
42
Space Temperature (SPT) Sensors
42
Indoor Air Quality (CO 2) Sensor
43
Outdoor Air Quality Sensor
43
Space Humidity Sensor or Humidistat
44
Smoke Detector/Fire Shutdown (FSD)
45
Connecting Discrete Inputs
45
Communication Wiring - - Protocols
46
General
46
Local Access
47
RTU Open Controller Troubleshooting
47
Outdoor Air Enthalpy Control
48
Differential Enthalpy Control
48
Return Air Enthalpy Sensor
48
Smoke Detectors
49
Step 11 - Adjust Factory- -Installed Options
50
Step 12 - Install Accessories
50
Step 13 - Check Belt Tension
51
Start- - up Checklist
55
Advertisement
Advertisement
Related Products
Bryant 551J*07A/G Series
Bryant 551J*07D/K Series
Bryant 551J*12D/K Series
Bryant 551J*11D/K Series
Bryant 551J*09D/K Series
Bryant 553A
Bryant 542J180
Bryant 542E048
Bryant 547KP06A
Bryant 547KP05A
Bryant Categories
Furnace
Air Conditioner
Heat Pump
Thermostat
Fan
More Bryant Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL