Sign In
Upload
Manuals
Brands
Bard Manuals
Controller
LC6000-200
Bard LC6000-200 PLC Lead/Lag Controller Manuals
Manuals and User Guides for Bard LC6000-200 PLC Lead/Lag Controller. We have
1
Bard LC6000-200 PLC Lead/Lag Controller manual available for free PDF download: Service And Installation Instructions
Bard LC6000-200 Service And Installation Instructions (37 pages)
Part of the Bard Cooling System
Brand:
Bard
| Category:
Controller
| Size: 1.6 MB
Table of Contents
Table of Contents
2
LC6000 Controller Installation
5
Typical LC6000-200 Component Location
5
LC6000 Controller
6
Mounting the LC6000 Controller
6
LC6000 Fused Power Supply Terminals
6
Supply Wiring
7
LC6000 Controller Supply Wiring
7
Controller Grounding Posts
7
Installing Remote Indoor Temperature/Humidity Sensor(S)
8
Remote Indoor Temperature/Humidity Sensor Installation
8
Figure 1 Figure
9
Additional Remote Sensor Installation
9
Figure 3 Figure
10
Remote Outdoor Temperature/Humidity Sensor Installation
10
Run Connections
11
Generator Run Connections
11
Communication Wiring
12
Communication Wiring: Termination at the Controller
12
Communication Wiring (Daisy Chain)
13
Communication Wiring (Alt. Method)
13
Figure 10 Communication Wiring (Daisy Chain)
13
Figure 6 Figure
14
Placement of Communication Filters
14
Alarms
15
Alarm Adjustment
15
Acknowledging/Clearing Alarms
15
High Temperature Alarm
15
Low Temperature Alarm
15
Adjust Alarm Setpoints
15
Adjust Alarm Remote Notification Relay Output Direction
15
High Temperature 2 Alarm
16
Emergency off Alarm
16
Adjust Emergency Off, Emergency Vent or Generator Alarm Input Direction
16
Generator Alarm
17
Adjust Alarm Remote Notification Relay Output Direction
17
Adjust Units Running When Generator Is Active
17
Emergency Vent Alarm
18
Zone Unit Alarm
18
Humidity Alarm
19
Adjust Zone Alarm Configuration
19
Adjust Humidity Alarm Setpoints
20
Control Operation
21
Temperature Control
21
Indoor Temperature Averaging
21
Staging
21
Comfort Mode
21
FIFO (First in First Out)
21
LIFO (Last in First Out)
21
Demand Staging
21
Change Indoor Temperature Averaging Type
21
Staging Delay
22
Maximum Number of Units Running
22
Rotation
22
Adjust Staging Settings
22
Staging Maximum Number of Units Running
22
Demand
23
Humidity Control
23
Dehumidification
23
Rotation
23
Humidification
24
Enabling Humidifier
24
Humidity Control Setpoints
24
Dehumidification Types
24
Continuous Blower
25
Continuous Blower Custom Configuration
25
Continuous Blower Status
25
Additional Information
26
LC6000 Menus/Screens
26
Main Menu
26
Status Screen
26
Quick Menu
26
Alarm Log
26
Info
26
Setpoints
26
MULTI-TEC Unit Info Screen
26
FUSION-TEC WR Series Unit Info Screen
26
Additional Programming
27
Changing to Celsius
27
Configuring Number of Units
27
Menu Screens and Password Levels
27
LC6000 Passwords (Defaults)
27
LC6000 Status Messages
27
Calibrating Sensors
28
Clearing Alarm Logs
28
Configuring Free Cooling
28
Enabling High Sensible Operation
28
Clearing LC6000 Alarm Logs
28
Enabling High Sensible Operation
29
Troubleshooting
30
8403-079 Sensor
30
8403-079 Sensor: Temp/Resistance
31
8403-079 Sensor: Voltage/Humidity
32
8301-090 Outdoor Temp/Humidity Sensor
33
8301-090 Sensor
33
8301-090 Sensor: Temp/Resistance
33
LC6000-200 Terminal Block Index
34
LC6000-200 to Sensor Connection Index
35
Figure 38
36
LC6000-200 Wiring Diagram
36
LC6000 Replacement Parts List
37
Manual 2100-669F
37
Advertisement
Advertisement
Related Products
Bard LV1000-100
Bard LC5000
Bard LV1000
Bard AB3000-A
Bard AB3000-B
Bard BrightStat 8403-081
Bard BrightStat 8403-082
Bard BrightStat 8403-083
Bard BrightStat 8403-084
Bard CB5000
Bard Categories
Air Conditioner
Heat Pump
Medical Equipment
Furnace
Controller
More Bard Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL