Sign In
Upload
Manuals
Brands
Agilent Technologies Manuals
Cash Counter
53152A
Agilent Technologies 53152A Manuals
Manuals and User Guides for Agilent Technologies 53152A. We have
2
Agilent Technologies 53152A manuals available for free PDF download: Operating Manual, Service Manual
Agilent Technologies 53152A Operating Manual (142 pages)
Microwave Frequency Counter
Brand:
Agilent Technologies
| Category:
Cash Counter
| Size: 2.38 MB
Table of Contents
Table of Contents
3
In this Guide
7
Contents and Organization
8
Related Documents
9
Types of Service Available if Instrument Fails
10
Repackaging for Shipment
11
Description of the Microwave Frequency Counter
12
Options
13
Accessories Supplied and Available
14
Manuals Supplied
14
Operating Guide
14
Agilent 53150A/151A/152A Quick Reference Guide
15
Frequency Counter
17
Getting Started
19
The Front Panel at a Glance
20
The Front Panel Indicators at a Glance
21
The Front Panel Menus at a Glance
22
The Display Annunciators at a Glance
23
The Display Special Characters at a Glance
24
The Rear Panel at a Glance
25
Operating the Counter
26
Turning the Counter on
28
Turning the Display Backlight off or on
29
Using the Menu
30
Displaying the Menu
30
Navigating in the Menu and Changing Settings
30
Setting the Serial Port Baud Rate (Menu Example)
33
Selecting the Input Channel
34
Measuring Frequency
35
Measuring Relative Frequency
37
Offsetting a Frequency Measurement
38
Chapter 1 Getting Started
39
Measuring Power (Channel 2 Only)
40
Selecting the Unit of Measurement for Power
41
Measuring Relative Power
42
Offsetting a Power Measurement
42
Operating Guide
42
Using Power Correction
44
Power Correction Theory of Operation
44
Increasing Profile Accuracy
45
Selecting a Power-Correction Profile
46
Entering Data Points in a Power-Correction Profile
46
Setting the Measurement Rate
50
Setting the Number of Averages
51
Setting the Resolution
52
Chapter 2 Operating Your Frequency Counter
55
Introduction
56
Chapter Summary
56
How this Counter Works for You
57
Summary of the Measurement Sequence
58
Using the Selection Keys
59
Sequencing through the Menu
59
Numeric Entry
60
Changing States
61
Using the Clear and Reset/Local Keys
63
Acknowledging Messages
63
Other Function Selection Keys
64
Measuring Frequency
66
Setting the Resolution and the Measurement Rate
68
Setting the Resolution
68
Setting the Measurement Rate
70
Rate Setting Example
70
Setting the Resolution and Measurement Rate
68
Resolution Setting Example
69
Setting the Number of Averages
71
Averages Setting Example
71
Measuring Relative Frequency
74
Relative Frequency Example
74
Offsetting a Frequency Measurement
75
Frequency Offset Example
75
Measuring Power
78
Power Measurement Example
78
Measuring Relative Power
80
Relative Power Example
80
Offsetting a Power Measurement
81
Power Offset Example
81
Using Power Correction
84
Power Correction Theory of Operation
85
Increasing Profile Accuracy
86
Power Correction Examples
86
Power Correction Example: Selecting a Correction Profile
87
Power Correction Example: Editing Data Point Values
89
Using the Menu
93
Navigating in the Menu and Changing Settings
95
Reference Oscillator (REF OSC)
96
Do Self Test
97
Battery Voltage (BATT VOLTAGE)
97
Operating Hours (OP HOURS)
97
Model Number, Firmware Version, Serial Number, and Option Codes
97
Preset
99
Serial Port Data Rate (BAUD)
100
Frequency Modulation (FM)
100
Channel 1 Low-Pass Filter (CH1 LPF)
100
Recall User Settings (RECALL)
100
Save User Settings (SAVE)
100
Power Correction (PWR CORR)
100
Specifications Introduction
102
Rack Mounting the Counter Rack Mounting the Counter
110
Operating Guide
114
Overview
114
Status Messages
114
Self-Test Messages
115
Error Messages
118
Using the Battery Option
119
Overview
120
Operating the Counter from the Batteries
120
Operating the Counter from a DC Power Source
121
Replacing the Batteries
122
Removing the Batteries
122
Installing Batteries
123
Charging the Batteries
126
Precautions
127
Declaration of Conformity
141
Advertisement
Agilent Technologies 53152A Service Manual (111 pages)
Microwave Frequency Counter
Brand:
Agilent Technologies
| Category:
Laboratory Equipment
| Size: 1.91 MB
Table of Contents
Table of Contents
4
How to Use this Guide
8
Repair Strategy
8
Instrument Identification
9
Instruments Covered by this Guide
9
Assembly-Level Service Guide Organization
9
How to Order Guides
10
Description of the Microwave Frequency Counter
11
Options
12
Hardware
12
Support
12
Accessories Supplied and Available
13
Accessories Supplied
13
Accessories Available
13
Manuals Supplied
13
Performance Tests Introduction
15
Operational Verification
15
Complete Performance Tests
16
Recommended Calibration Cycle
16
Test Record
16
Equipment Required
17
Operational Verification
19
10 Mhz Test
19
Run Self Test
20
External Timebase Test
21
10 Mhz External Timebase Input Test
21
Complete Performance Tests
24
Test 1: External Timebase Input Test
25
Mhz External Timebase Input Test
25
Mhz External Timebase Input Test
27
10 Mhz External Timebase Input Test
28
Test 2: Channel 1 Frequency Sensitivity
29
Test 2A: 10 Hz to 20 Mhz Frequency Sensitivity
29
Test 2B: 50 Mhz to 125 Mhz Frequency Sensitivity
31
Test 3: Channel 2 Frequency Sensitivity
34
Test 3A: 50 Mhz to 20 Ghz Frequency Sensitivity
34
Test 3B: 22 Ghz to 26.5 Ghz Frequency Sensitivity
36
Test 3C: 30 Ghz to 46 Ghz Frequency Sensitivity
37
Test 4: Channel 2 Power Measurement
38
Test 4A: 50 Mhz to 20 Ghz Power Measurement (-20 Dbm)
38
Test 4B: Channel 2 22 Ghz to 26.5 Ghz Power Measurement (-20 Dbm)
40
Test 4C: Channel 2 26.5 Ghz to 46 Ghz Power Measurement (-20 Dbm)
41
Test 4D: Channel 2 50 Mhz to 20 Ghz Power Measurement (0 Dbm)
41
Test 4E: Channel 2 22 Ghz to 26.5 Ghz Power Measurement (0 Dbm)
42
Test 4F: Channel 2 30 Ghz to 46 Ghz Power Measurement (0 Dbm)
42
Performance Test Record (Page 1 of 4)
43
Performance Test Record (Page 2 of 4)
44
Performance Test Record (Page 3 of 4)
45
Performance Test Record (Page 4 of 4)
46
Service Introduction
49
Returning the Counter to Agilent Technologies for Service
50
Providing Repair Information
50
Calibration Procedure
53
Equipment Required
53
Pre-Troubleshooting Information
55
Safety Considerations
55
Recommended Test Equipment
56
Repair Considerations
56
Electrostatic Discharge
56
Surface Mount Repair
57
Disassembly and Reassembly Specifics
57
After Service Considerations
57
Product Safety Checks
57
Product Performance Checks
58
Assembly Identification and Location
58
Troubleshooting the Counter
60
Power Supply Check
60
Adjusting the +5 VDC Output
61
Self-Test
62
Running the Self Test
62
Self Test Error Messages
63
Replacing Assemblies Introduction
67
Tools Required
68
Do this First
68
Removing the Bumpers
69
Removing the Handle and Handle Mounts
70
Removing the Rear Bezel
71
Removing the Shroud
73
Removing the Front Bezel
76
Removing the Rear Panel Assembly
77
Removing the Cooling Fan
80
Replacing the Power Supply
81
Replaceable Parts Introduction
85
Replaceable Parts
85
How to Order a Part
86
Contacting Agilent Technologies
87
Parts Identification
88
Reference Designations
88
Cabinet Parts and Hardware
88
Accessories and Miscellaneous Items
88
Backdating Introduction
97
Specifications
98
Introduction
99
Measurement Specifications and Characteristics
100
Typical Power Measurement Uncertainty at 25°C for Various Input Levels
102
Typical Power Measurement Uncertainty at −25 Dbm Input Level
103
Advertisement
Related Products
Agilent Technologies 53150A
Agilent Technologies 53151A
Agilent Technologies 53181A
Agilent Technologies 53131A
Agilent Technologies 53132A
Agilent Technologies 53220A
Agilent Technologies 53230A
Agilent Technologies 53210A
Agilent Technologies 53147A
Agilent Technologies 53148A
Agilent Technologies Categories
Measuring Instruments
Laboratory Equipment
Test Equipment
Water Pump
Power Supply
More Agilent Technologies Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL