DAIKIN AIR CONDITIONER
• Read these Safety Precautions carefully to ensure correct installation.
• This manual classifies the precautions into DANGER, WARNING and CAUTION. Be sure to follow all the
precautions below: they are all important for ensuring safety.
DANGER
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.
CAUTION
Failure to follow any of CAUTION may in some cases result in grave consequences.
• The following safety symbols are used throughout this manual:
Be sure to observe this instruction.
• After completing installation, test the unit to check for installation errors. Give the user adequate instructions
concerning the use and cleaning of the unit according to the Operation Manual.
DANGER
• Refrigerant gas is heavier than air and replaces oxygen. A massive leak could lead to oxygen depletion, especially in
basements, and an asphyxiation hazard could occur leading to serious injury or death.
• If the refrigerant gas leaks during installation, ventilate the area immediately.
Refrigerant gas may produce a toxic gas if it comes in contact with fire such as from a fan heater, stove or cooking device.
Exposure to this gas could cause severe injury or death.
• After completing the installation work, check that the refrigerant gas does not leak.
Refrigerant gas may produce a toxic gas if it comes in contact with fire such as from a fan heater, stove or cooking device.
Exposure to this gas could cause severe injury or death.
• Do not ground units to water pipes, telephone wires or lightning rods because incomplete grounding could cause a
severe shock hazard resulting in severe injury or death, and to gas pipes because a gas leak could result in an
explosion which could lead to severe injury or death.
• Safely dispose of the packing materials.
Packing materials, such as nails and other metal or wooden parts, may cause stabs or other injuries.
Tear apart and throw away plastic packaging bags so that children will not play with them.
Children playing with plastic bags face the danger of death by suffocation.
• Do not install unit in an area where flammable materials are present due to risk of explosion resulting in serious
injury or death.
• Do not ground units to telephone wires or lightning rods because lightning strikes could cause a severe shock hazard
resulting in severe injury or death, and to gas pipes because a gas leak could result in an explosion which could lead
to severe injury or death.
Safety Precautions (1)
Be sure to establish an earth connection.
3P235796-1F M08B133E
Two-dimensional bar code
is a code for manufacturing.
Never attempt.

Advertisement

Table of Contents
loading

Summary of Contents for Daikin RKS30

  • Page 1 3P235796-1F M08B133E DAIKIN AIR CONDITIONER Two-dimensional bar code is a code for manufacturing. Safety Precautions (1) • Read these Safety Precautions carefully to ensure correct installation. • This manual classifies the precautions into DANGER, WARNING and CAUTION. Be sure to follow all the precautions below: they are all important for ensuring safety.
  • Page 2: Safety Precautions

    Safety Precautions (2) WARNING • Installation should be left to the authorized dealer or another trained professional. Improper installation may cause water leakage, electrical shock, fire, or equipment damage. • Install the air conditioner according to the instructions given in this manual. Incomplete installation may cause water leakage, electrical shock, fire or equipment damage.
  • Page 3: Precautions For Selecting The Location

    Accessories Accessories supplied with the outdoor unit: (A) Installation manual (B) Drain socket assy (C) Tube (D) Binding band Precautions for Selecting the Location 1) Choose a place solid enough to bear the weight and vibration of the unit, where the operation noise will not be amplified.
  • Page 4: Outdoor Unit Installation Drawings

    Outdoor Unit Installation Drawings Model 30/36 class Max. allowable length 98.4ft (30m) Min. allowable length 6.6ft (2m) Max. allowable height 65.6ft (20m) Wrap the insulation Additional refrigerant pipe with the finishing required for refrigerant 0.55oz/ft tape from bottom to top. pipe exceeding 32ft (50g/m) (10m) in length.
  • Page 5: Installing Outdoor Unit

    Outdoor Unit Installation (1) Installing outdoor unit. 1) When installing the outdoor unit, refer to “Precautions for Selecting the Location” and the “Outdoor Unit Installation Drawings”. 2) If drain work is necessary, follow the procedures below. Drain work. • Use drain plug for drainage. •...
  • Page 6: Flaring The Pipe End

    Outdoor Unit Installation (2) Flaring the pipe end. Flaring Set exactly at the position shown below. 1) Cut the pipe end with a pipe cutter. Flare tool for R410A Conventional flare tool 2) Remove burrs with the cut surface facing Clutch-type Wing-nut type Clutch-type...
  • Page 7: Purging Air And Checking Gas Leakage

    Outdoor Unit Installation (3) Purging air and checking gas leakage. • When piping work is completed, it is necessary to purge the air and check for gas leakage. WARNING 1) Do not mix any substance other than the specified refrigerant (R410A) into the refrigeration cycle. 2) When refrigerant gas leaks occur, ventilate the room as soon and as much as possible.
  • Page 8: Pump Down Operation

    Outdoor Unit Installation (4) Refilling the refrigerant. Check the type of refrigerant to be used on the machine nameplate. Filling a cylinder with an Filling other cylinders Precautions when adding R410A attached siphon Fill from the liquid pipe in liquid form. Stand the cylinder upright Turn the cylinder when filling.
  • Page 9 Wiring (1) WARNING 1) Do not use spliced wires, stranded wires (CAUTION (1)), extension cords, or starburst connections, as they may cause overheating, electrical shock, or fire. Follow all local, and state electrical codes. 2) Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc., from the terminal block.) Doing so may cause electric shock or fire.
  • Page 10 Wiring (2) • Do not turn ON the safety breaker until all Firmly fix the wires with the terminal screws. work is completed. Outdoor unit Strip the insulation from the wire (3/4 inch 1 2 3 If the length of a connection wire is (20mm)).
  • Page 11 Facility Setting Switch (cooling at low outdoor temperature) This function is limited only for facilities (the target of air conditioning is equipment (such as computer)). Never use it in a residence or office (the space where there is a human). 1) You can expand the operation range to 5˚F (–15˚C) by turning on switch B (SW4) on the PCB.
  • Page 12: Trial Operation And Testing

    Trial Operation and Testing Trial operation and testing. 1-1 Measure the supply voltage and make sure that it falls in the specified range. 1-2 Trial operation should be carried out in either cooling or heating mode. n For heat pump 1) In cooling mode, select the lowest programmable temperature;...
  • Page 13 3P235796-1F M08B133E...

This manual is also suitable for:

Rks36Rxs30Rxs36

Table of Contents