Installation; Technical Specifications - Lincoln Electric Invertec V450-PRO User Manual

Hide thumbs Also See for Invertec V450-PRO:
Table of Contents

Advertisement

A-1

TECHNICAL SPECIFICATIONS -

INPUT AT RATED OUTPUT - THREE PHASE ONLY
INPUT VOLTS
380-415V
50/60HZ.
PULSE
FREQUENCY
0.15 - 1000 Hz
OPEN CIRCUIT VOLTAGE
30-76
76
76
18-76
76
INPUT
VOLTAGE /
FREQUENCY
380-415
50/60 Hz
HEIGHT
26.10 in
663 mm
OPERATING TEMPERATURE RANGE
-20°C to +40°C

INSTALLATION

INVERTEC V450-PRO (CE)
OUTPUT
CONDITIONS
400A@36V 100%
500A@40V 60%
PULSE
VOLTAGE
RANGE
5 - 55 VDC
PROCESS CURRENT RANGE (DC)
RECOMMENDED INPUT WIRE AND FUSE SIZES
TYPE 75°C
COPPER WIRE IN
CONDUIT AWG
(MM
2
) SIZES
8 (10)
PHYSICAL DIMENSIONS
WIDTH
19.86 in
505 mm
TEMPERATURE RANGES
INVERTEC V450-PRO (CE)
INPUT
CURRENT
48
OUTPUT
PULSE AND
BACKGROUND
TIME RANGE
100 MICRO SEC. -
3.3 SEC.
MIG/MAG
FCAW
SMAW
GTAW
Pulse
TYPE 75°C
GROUND WIRE IN
CONDUIT AWG
(MM
2
) SIZES
10 (6)
DEPTH
32.88 in
835 mm
STORAGE TEMPERATURE RANGE
INPUT
I
max
CURRENT
1
37
AUXILIARY
POWER
220 VAC AT
5 AMPS
24VAC
42VAC at
10 AMPS
CURRENT
50-500 Average Amps
40-500 Average Amps
55-500 Average Amps
5-500 Average Amps
5-750 Peak Amps
TYPE 75°C
(SUPER LAG)
OR BREAKER
SIZE (AMPS)
63 AMP
WEIGHT
278 lbs.
126 kg.
-40°C to +40°C
A-1
I
eff
1

Advertisement

Table of Contents
loading

Table of Contents