FLAME APPEARANCE

Flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed.
In addition, periodically check the flames visually during operation.
CHECKING THE PILOT FLAME
The pilot fl ame must always be present when the heater is in operation. It should just touch the top of the ther-
mocouple tip for natural. See Figure 31 for correct pilot flame.
If the pilot flame does not touch the thermocouple, then the main burner cannot function reliably. See Figure 32 for incor-
rect shape of pilot flame.
THERMOSTAT AND MILLI-VOLT CONTROL
Thermocouple
for Natural
Thermocouple
for LP
Figure 31 - Correct Appearance of Pilot Flame
26
Thermocouple
for Natural
Thermocouple
for LP
Figure 32 - Incorrect Appearance of Pilot Flame
23D8036