SF42A, SF42AI, SCF42A SCF42AI ESIDENTIAL IREPLACES NSTALLATION PERATION AND AINTENANCE ANUAL 42 I UILT URNING IREPLACES GLASS DOORS FAN ASSEMBLY AND OUTSIDE COMBUSTION AIR KIT AVAILABLE SF42 SERIES U. L. ® HESE FIREPLACES ARE LISTED FOR USE "S" S SCF42 WITH ERIES CHIMNEY SYSTEM COMPONENTS SERIES...
ONGRATULATIONS You have chosen a fine woodburning fireplace. These fireplaces have been designed and manufac- tured for years of heating and viewing enjoyment. Please take time to read this entire manual before installing or operating your fireplace. ABLE OF ONTENTS Listing And code Approvals...................2 Important Information............
The use of improper parts in the installation can be hazardous and voids the warranty offered by Martin Hearth & Heating. This fireplace is designed to burn wood. This fireplace is not designed to burn coal, unplumbed liquid fuels, unplumbed gaseous fuels or household refuse. Any attempt to burn these fuels in the fireplace can be hazardous.
LEARANCES (FLUE OUTLET HEIGHT) IGURE RESIDENTIAL INSTALLATION 14 FT. = MIN. HEIGHT (NO OFFSETS) 14 FT. = MIN. HEIGHT (2-30˚ ELBOWS) ELBOWS) ROUND CHIMNEY CAP 21 FT. = MIN. HEIGHT (4-30˚ ELBOWS) ELBOWS) MODEL SC 86 FT. = MAX. HEIGHT (CHIMNEY SUPPORT EVERY 30 FT.) ROOF FLASHING STORM...
IREPLACE OCATION CAUTION: Do not install fireplace over carpeting. This fireplace does not weigh more than large pieces of furniture and can normally be located near a load bearing wall without requiring additional foundations or supports. If however, the fireplace is to be trimmed with a heavy stone or brick facing and hearth extension, be sure the supporting structure is adequate.
NSTALLATION REPARATION Survey the planned location for the fireplace for overhead plumbing or electrical wires, etc., that might complicate the installation or endanger persons installing or cleaning the chimney. Avoid a location where the chimney cap will be near abrupt changes in the roof shape, nearby wall or embankments, under or near trees or above the roof of a single story wing of a two story building as shown by Figure 8.
Page 9
NSTALLATION REPARATION IGURE SINGLE STORY INSTALLATION WITH SINGLE STORY INSTALLATION WITH ATTIC SPACE ATTIC SPACE SC CHIMNEY CAP SC CHIMNEY CAP FLUE OUTLET HEIGHT FLUE OUTLET HEIGHT STORM COLLAR STORM COLLAR 3 FT. MIN. OR 2 FT. ABOVE 3 FT. MIN. OR 2 FT. ABOVE ANY POINT WITHIN 10 FT.
LOOR ROTECTION If this fireplace is installed on a combustible floor, the floor area 20 inches in front of, and 12 inches either side of the fireplace opening must be protected by an insulating noncombustible hearth extension. This hearth extension may be either minimum 6-inch thick stone or brick as shown by Figure 10, an H2066 Hearth Extension Kit or a locally constructed hearth equivalent to the H2066.
Page 11
LOOR ROTECTION The ability of insulating material to retard the transfer of heat may be expressed as either Thermal Conduc- tance (C), Thermal Conductivity (K), or Thermal Resistance (R). The mathematical relationship of these values and the formulas for converting one value to another is as follows: IGURE C = K divided by the material thickness (Example C = .43 divided by 1/2 (.50)
Page 12
IREPLACE OMPONENTS IGURE GD42B OR GD42PB CHIMNEY SCF42A/SCF42AI SF42A/SF42AI GLASS DOOR KIT SUPPORT SF FIRESTOP H2066 HEARTH 612-1212 SC ROUND SPACER EXTENSION KIT SE30 30∞ FLASHING CHIMNEY CAP ELBOW 403 DUCT AK4 COMBUSTION FP-4-U CONNECTOR AIR ASSEMBLY UNINSULATED FA2 FAN ASSEMBLY FLEX PIPE CHIMNEY CAP...
Before beginning the installation, be sure you have the proper parts in sufficient quantity. Refer to the Parts Diagram and List section of this manual for proper identification of parts. Do not substitute parts. Use only parts listed for use with Martin Hearth & Heating Models SF42A, SF42AI, SCF42A, and SCF42AI fireplaces.
HIMNEY NSTALLATION IGURE NOTE: FLUE OUTLET SHOULD BE TWO FEET ABOVE ALL PORTIONS OF NOTE: FLUE OUTLET SHOULD BE TWO FEET ABOVE ALL PORTIONS OF THE BUILDING WITHIN TEN FEET AS SHOWN BY THESE ILLUSTRATIONS. THE BUILDING WITHIN TEN FEET AS SHOWN BY THESE ILLUSTRATIONS. THE CHIMNEY MUST NOT EXTEND MORE THAN 90 INCHES ABOVE THE CHIMNEY MUST NOT EXTEND MORE THAN 90 INCHES ABOVE "A"...
Page 16
HIMNEY NSTALLATION TABLE 1 IGURE MINIMUM REQUIRED ROOF OPENING ACTUAL MINIMUM FRAMED OPENING CENTER POINT CENTERLINE "S" SERIES DOUBLE "E" SERIES DOUBLE OF CHIMNEY ROOF PITCH WALL CHIMNEY WALL CHIMNEY WALL CHIMNEY WALL CHIMNEY 0/12 14 1/2" x 14 1/2" 17"...
HIMNEY FFSET NSTALLATION LBOW NSTALLATION The following are important points that should be observed when installing elbows on the fireplace: 1. The support straps of all elbows not installed directly on top of the fireplace should be nailed securely to the surrounding structure.
Page 18
HIMNEY FFSET AND NSTALLATION CONTINUE CHIMNEY TO PROPER CONTINUE CHIMNEY TO PROPER HEIGHT AND INSTALL ROUND HEIGHT AND INSTALL ROUND IGURE CHIMNEY CAP OR CHIMNEY CHIMNEY CAP OR CHIMNEY 14-1/2" IGURE HOUSING. HOUSING. 22-1/16" STORM COLLAR STORM COLLAR FLASHING FLASHING SF FIRESTOP SPACER.
HIMNEY NSTALLATION SC C ODEL HIMNEY : The proper height as previously explained is important to assure proper draft and safety. The PECIAL chimney cap extends the flue outlet four inches above the top of the last section of chimney. This should be kept in mind when determining the proper height for the chimney.
Page 20
HIMNEY EIGHT AND FFSET HARTS ABLE STRAIGHT RUN CHIMNEY SECTIONS CHIMNEY SECTIONS WITH ELBOW OFFSETS TOTAL TOTAL INTERMEDIATE CHIMNEY SECTIONS ELBOW INCHES INCHES HEIGHT SECTIONS 12" 18" 36" 48" OFFSET RISE (INCHES) 12" 18" 36" 48" 4 1/2 26 1/2 31 3/4 15 1/2 41 1/4...
HIMNEY HASE NSTALLATION The preinstalled chimney sections should be no more than 10 inches below the top of the chase. The installation should be planned so that either an 18-inch or 36-inch chimney section will be used for the top section. This is necessary to ensure complete engagement of the inlet air telescope and chimney cap into the top section.
& R UTSIDE OMBUSTION RECAUTIONS ECOMMENDATIONS : The use of outside air for combustion is optional unless required by building codes. It is only necessary to supply outside combustion air to one side of the fireplace. Use the model AK4 combustion air kit. IGURE SECURING OUTSIDE AIR STARTING COLLAR TO FIREPLACE SECURING OUTSIDE AIR STARTING COLLAR TO FIREPLACE...
Page 23
& R UTSIDE OMBUSTION RECAUTIONS ECOMMENDATIONS UTSIDE OMBUSTION ECOMMENDATIONS CONTINUED 1. Extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air assembly should be avoided. These conditions will increase the resistance to the free flow of air through the duct.
OMBUSTION SSEMBLY AK4 C ODEL OMBUSTION SSEMBLY 1. Remove the cover plate from the 4-inch outlet opening location on the left or right outside of the fireplace. DO NOT remove the cover if the outside air will not be connected. 2.
PPLIANCE NSTALLATION Improper installation or operation of a gas appliance in this fireplace can allow unburned gas to leak ARNING out which will cause a fire or explosion hazard, or the release of poisonous carbon monoxide into the dwelling which can cause serious injury or death to its inhabitants. To reduce these risks to a minimum, the following important notices and instructions should be read and followed carefully.
Page 26
PPLIANCE NSTALLATION 8. Be sure the gas is turned off at the appliance, then turn the gas on at the cut off valve and test the gas line connections for leaks with soapy water solution or a liquid leak detector. DO NOT USE A MATCH OR OTHER FLAME SOURCE TO CHECK FOR GAS LEAKS.
NSTALLATION INSTALLATION OF NON-COMBUSTIBLE FACING MATERIALS TO THE FRONT FACE OF THE FIREPL INSTALLATION OF NON-COMBUSTIBLE FACING MATERIALS TO THE FRONT FACE OF THE FIREPLACE NON-COMBUSTIBLE FACING MATERIAL USE ONLY NON-COMBUSTIBLE COMBUSTIBLE FRAMING MATERIALS BELOW TOP OF SPACERS. MEMBERS FACING MATERIAL TO TOP OF SPACERS.
LASS NSTALLATION AND CCESSORY LASS NSTALLATION This fireplace has been tested and listed for use with optional Model GD42P or GD42PB glass doors. For installation of the Models GD42P or GD42PB glass doors, see the instructions provided with the doors. SSEMBLY The model SCF42A and SCF42AI Fireplaces may be equipped with a accessory fan Model FA2.
IREPLACE PERATION : If a decorative gas appliance is used in the fireplace the fireplace damper must be fixed in an open ARNING position. (See additional operation information in section titled “Operation Guidelines”.) DVANTAGES OF A URNING IREPLACE These are the practical, ecological advantages of wood as a fuel. Also to be considered is the aesthetic appeal.
Page 30
IREPLACE PERATION You’ll need a minimum of three logs, preferably four, to make a good fire. Add kindling and new logs as needed to rekindle a dying fire. New logs should be added at the rear grate after raking the coals toward the front. D .
Make sure the chimney is clear from any accumulation of soot, creosote or any other debris, and that all joints are intact. Martin Hearth & Heating does not recommend chemical cleaners because some may contain elements that corrode the metal parts of the chimney or fireplace.
Page 32
AINTENANCE AND AFETY IREPLACE AINTENANCE At the end of each heating season or when the fireplace will not be in use for an extended time, the ashes should be removed and the hearth area should be swept as clean as is practical. The slow absorption of moisture into the ashes over a long period of time could cause a condition which would be corrosive to the metal fireplace parts.
Page 33
25. Don’t clean the chimney with metallic devices or chemical cleaners. 26. Don’t use the fireplace or chimney for venting wood or coal burning heaters or inserts unless approved in writing by Martin Hearth & Heating. 27. Don’t put combustibles within 24 inches of the fireplace opening "W...
EPAIR IAGRAMS AND ISTS All repair part orders should be placed through your local dealer. To ensure prompt and accurate service, please provide the following information when placing a repair part order: Model number of your Appliance, Part Name, Part Number, and Quantity of parts needed. Technical Service Department 2813 W.
Page 35
EPAIR IAGRAMS AND ISTS All repair part orders should be placed through your local dealer. To ensure prompt and accurate service, please provide the following information when placing a repair part order: Model number of your Appliance, Part Name, Part Number, and Quantity of parts needed. Technical Service Department 2813 W.
IMITATIONS AND XCLUSIONS 1. No one has authority to add to or vary this limited warranty, or to create for Martin Hearth & Heating any other obligation of liability in connection with this fireplace and accessory. 2. Martin Hearth & Heating...
Page 37
OMPONENT 1. Contact your nearest dealer. If you cannot locate your dealer, call or write Martin Hearth & Heating as indicated below. 2. If you do not receive satisfactory service from the dealer within a reasonable time, write Martin Hearth & Heating and include the date you purchased your fireplace or component, its serial number, and details of the problem you are having.