HOW TO SET THE AIR FLOW DIRECTION
(horizontal)
(downwards)
the position of the louver
[EXAMPLE] For Upper position 2, Lower position 6
Upper
position
Movable
range
Lower
position
Note : If the upper limit position number and the lower limit
position number are set to the same position, the louver
is fixed at that position. And auto swing does not function.
NOTICE
• If you press
RESET button during settings, the display will return to previous display. If you press
button during settings, the mode will end and the original display will return, and the settings that have not been
completed will become invalid.
• When plural remote controllers are connected, louver position setting cannot be set by slave remote control.
12
< WIRED REMOTE CONTROL >
7
Press
SET button (Fixing of the upper
limit position)
The upper limit position is fixed and the setting position is
displayed for two seconds. Then proceed to lower limit position
selection display.
[EXAMPLE]
"
" (lights for two seconds)
"
" (shows current setting)
8
Press ▲ or ▼ button (Selection of lower limit
position)
Select the lower limit position of louver.
"position 1" is the most horizontal, and "position 6" is the most
downwards.
"position --" is to return to the factory setting. If you need to
change the setting to the factory setting, use "position --".
"
" (the most horizontal)
 "
"
 "
"
 "
"
 "
"
 "
" (the most downwards)
 "
" (return to the position of shipment)
9
Press
SET button (Fixing of the lower limit
position)
The upper limit position and lower limit position are fixed, the set
positions lights for two seconds, and then the setting is completed.
• After the setting is completed, the louver which was set
moves from the original position to the lower limit position,
and goes back to the original position again. (This operation
is not performed if the indoor unit and/or indoor unit fan is in
operation.)
[Example]
"
" (lights for two seconds)
"
"
"
10
Press
button.
Louver adjusting mode ends and returns to the original display.

HOW TO OPERATE VENTILATION

(WHEN A VENTILATOR IS INSTALLED)
When the ventilator is set to "NO VENTI LINK", the ventilator can be turned on and off independently regardless
of the operation of the air conditioner.
When the ventilator is set to "VENTI LINK", the ventilator operation will be interlocked with the air conditioner
operation.
1

FOR COMFORTABLE USE

Clean the filter frequently
The filter should be cleaned when
the "Filter cleaning" message
See page 16
is displayed, and at the ends of
cooling and heating seasons.
If the filter is clogged...
• The cooling/heating capacity will get reduced. Moreover it leads
to waste of electricity and larger operation noise.
• It may cause failure.
• Dew may form and drop during cooling.
Do not block the inlet and outlet grilles of the
indoor and outdoor units.
Excessive load to the unit may cause failure.
Keep moderate room temperature
Too much cooling or heating is not good for your health. It will also
waste the electricity.
< WIRED REMOTE CONTROL >
VENTILATION OPERATION NOT LINKED WITH UNIT'S
OPERATION
1
Press
VENTI button.
"
" is displayed, and the ventilation operation begins.
Stop
Press
VENTI button again.
NOTICE
• If no ventilator is connected, no operation can be performed by
pressing the ventilation button. ("
" is displayed).
VENTILATION OPERATION LINKED WITH UNIT'S OPERATION
1
Press
button.
If a ventilator is connected, ventilation will operate automatically.
"
" is displayed.
Stop
Press
button again.
NOTICE
• No operation can be performed by pressing the ventilation button.
("
" is displayed).
Block direct sunlight and prevent draft
Block direct sunlight with blinds and curtains during cooling. Close
the windows and doors except when ventilation is necessary.
Adjust the airflow properly
Do not expose yourself directly to the airflow for too long time. For
small animals and plants, it is harmful as well.
If you feel cold underneath your feet during heating
If the ceiling is so high that the warm airflow does not circulate
underneath your feet, it is recommended to use a circulator.
Consult your dealer for more detail.
Stop the operation and turn the power supply
off if there are any possibility of lightning
strikes during a thunderstorm.
Lightning strikes may lead to the failure of air-conditioning system.