3. POWER AMPLIFIER ADJUSTMENT

Idling Current Alignment

1.
Each of the measurement points are provided with the
two test points. Set a digital Voltage meter to DC voltage
input, connect the meter to the test points at both contact
points.
2.
After the setup above, turn on the main switch.
3.
Adjust variable resistors (VR91 - VR97) according to the
digital voltmeter readings. The target setting value is the
following table for each channels.
Settings :
Master Volume — Minimum
Speaker out
— No Load
Top lid
— OPEN
CN63(2p)
VR93 or
VR9x
TR BIAS
PWB
DC voltmeter........Connect to CN6x
No.
Channel
1
Surround Left
2
Center
3
Surround Right
4
Front Left
5
Surroud Back Left
6
Front Right
7
Surroud Back Right
MAIN PWB
CUP12083Z
CN61(2p)
CN65(2p)
VR91 or
VR95 or
VR97 or
VR9x
VR9x
VR9x
Measuremet
Alignment
Point
Point
CN62
VR93 or VR9x
CN65
VR91 or VR9x
CN64
VR95 or VR9x
CN67
VR97 or VR9x
CN61
VR92 or VR9x
CN66
VR96 or VR9x
CN63
VR94 or VR9x
アイドリング電流調整
電源を
する前にそれぞれの
1.
ON
ルボルトメーターを接続します。デジタルボルトメーター
電圧入力にセットします。
DC
上記のセットアップの後に、本機の電源を
2.
デジタルボルトメーターの電圧値を監視しながら可変抵抗
3.
(VR91
VR97)
各チャンネルの目標値は下記の表を参照下さい。
セッティング
:
マスター・ボリューム ̶ 最小
スピーカー接続
トップカバー
CN67(2p)
CN62(2p)
CN66(2p)
VR92 or
VR96 or
VR9x
VR9x

Time Table of Idling Current Rise

After Turning ON
5 min
10 min
20 min
30 min
40 min
50 min
60 min
8
端子と
端子間にデジタ
"+"
"-"
します。
ON
を調節します。
̶ 無し
無し
––
CN64(2p)
VR94 or
VR9x
Measurement Voltage
(CN6x)
7.5 mV ± 0.5 mV
7.5 mV ± 0.5 mV
7.5 mV ± 0.5 mV
7.5 mV ± 0.5 mV
7.5 mV ± 0.5 mV
7.5 mV ± 0.5 mV
7.5 mV ± 0.5 mV