The 50A55 control board is equipped with two LED lights for troubleshooting. The diagnostic codes are listed below in table
3.
MAKE SURE TO ID LED'S CORRECTLY: REFER TO INSTALLATION INSTRUCTIONS FOR CONTROL BOARD LAYOUT.
LED #1
SIMULTANEOUS
SLOW FLASH
SIMULTANEOUS FAST
SIMULTANEOUS FAST
FLASH
SLOW FLASH
OFF
ALTERNATING SLOW
ALTERNATING SLOW
FLASH
SLOW FLASH
ON
ON
ON
OFF
FAST FLASH
SLOW FLASH
ALTERNATING FAST
ALTERNATING FAST
FLASH
NOTE − Slow flash equals 1 Hz (one flash per second). Fast flash equals 3 Hz (three flashes per second). Drop out flame sense current < 0.15 microAmps
1
É É
É É É É
ON
Pre -Purge
OFF
É É É É É É É É É É É É É É É É É É É É É É É É
DEMAND
É É É É É É É É É É É É É É É É É É É É É É É É É É
É É É É É É É É É É É É É É É É É É É É É É É É
CAB
IGNITOR
É É É É É É É É É É É É É É É É É É É É É É É É É É
GAS VALVE
INDOOR BLOWER
*Blower on time will be 45 seconds after ignition. Blower off time will depend on OFF TIME" Setting.
TABLE 3
DIAGNOSTIC CODES
LED #2
SIMULTANEOUS
SLOW FLASH
Normal operation − signaled when heating demand initiated at thermostat.
FLASH
Primary or Secondary limit open. Units with board 12L42: Limit must close within
5 trials for ignition or board goes into one hour limit Watchguard. Units with board
ON
56L85: Limit must close within 3 minutes or board goes into one hour limit Watch-
Pressure switch open or has opened 5 times during a single call for heat; OR:
Blocked inlet/exhaust vent; OR: Condensate line blocked; OR: Pressure switch
SLOW FLASH
FLASH
OFF
SLOW FLASH
ON
OFF
ON
SLOW FLASH
Low flame signal. Measures below .7 microAmps. Replace flame sense rod.
FAST FLASH
Improper main ground or line voltage below 75 volts; OR: Broken ignitor; OR:
FLASH
50A55 Control Board Ignition Sequence
15
Ignitor Warmup
É É É É É É É É
DESCRIPTION
Power − Normal operation
Also signaled during cooling and continues fan.
closed prior to activation of combustion air blower.
Watchguard − burners fail to ignite.
Flame sensed without gas valve energized.
Rollout switch open. OR: 9 pin connector improperly attached.
Circuit board failure or control wired incorrectly.
Main power polarity reversed. Switch line and neutral.
Open ignitor circuit.
40
37
36
Trial for
Blower On"
Ignition
Delay
É É É É É É É É É É É É É É
É É É É É É É É É É É É É É
FIGURE 5
Page 10
guard.
82
É É É É É É É É É
É É É É É É É É É
5 SEC
Post
Purge