Sanyo VPC-E10 Service Manual page 18

Hide thumbs Also See for VPC-E10:
Table of Contents

Advertisement

AF_WIDE: ZW
ZW: adjustment value of focus at zoom position wide
(–88<=ZW<=50)
AF_MID1: ZM1
ZM1: adjustment value of focus at zoom position middle1
(–109<=ZM1<=61)
AF_MID2: ZM2
ZM2: adjustment value of focus at zoom position middle2
(–132<=ZM2<=69)
AF_MID3: ZM3
ZM3: adjustment value of focus at zoom position middle3
(–153<=ZM3<=74)
AF_MID4: ZM4
ZM4: adjustment value of focus at zoom position middle4
(–159<=ZM4<=78)
AF_MID5: ZM5
ZM5: adjustment value of focus at zoom position middle5
(–164<=ZM5<=89)
AF_MID6: ZM6
ZM6: adjustment value of focus at zoom position middle6
(–174<=ZM6<=92)
AF_MID7: ZM7
ZM7: adjustment value of focus at zoom position middle7
(–174<=ZM7<=97)
AF_TELE: ZT
ZT: adjustment value of focus at zoom position tele
(–167<=ZT<=83)
2. Lens Adjustment (Infinity)
Camera
Preparation:
POWER switch: ON
If using a ready-made collimator, set to infinity.
The tester should be used to adjust the voltage between the
terminals of the power connector that is being supplied from
the power supply (voltage between the battery socket termi-
nals of the camera) to 4.1 ± 0.1 V.
Note:
Do not vibrate during the adjustment.
Collimator
Adjustment method:
1. Set the camera so that it becomes center of the siemens
star chart in the collimator. (zoom wide and tele)
(Set a distance of 0.5-1.0 cm between camera lens and
collimator lens when zoom tele edge. Do not touch the
each lens.)
2. Double-click on the DscCalDi.exe.
3. Select "Infinity Cal." on the LCD "Test", and click the "Yes".
4. Lens infinity adjustment value will appear on the screen.
5. Click the OK.
Dsc Calibration
Infinity calibration :
AF_TEMP_AD: 458
AF_I_WIDE: 9
AF_I_MID1: 11
AF_I_MID2: 15
AF_I_MID3: 18
AF_I_MID4: 13
AF_I_MID5: 7
AF_I_MID6: -2
AF_I_MID7: -10
AF_I_TELE: -7
Adjustment value determination is effectuated using below val-
ues.
The adjustment values fulfill the conditions below, they are de-
termined as within specifications.
Adjustment value determination
AF_TEMP_AD: ATAD
ATAD: adjustment value of AD value of temperature in
focus lens (326<=ATAD<=897)
AF_I_WIDE: ZIW
ZIW: infinity adjustment value of focus at zoom position
wide (–89<=ZIW<=43)
AF_I_MID1: ZIM1
ZIM1: infinity adjustment value of focus at zoom position
middle1 (–111<=ZIM1<=56)
AF_I_MID2: ZIM2
ZIM2: infinity adjustment value of focus at zoom position
middle2 (–137<=ZIM2<=65)
AF_I_MID3: ZIM3
ZIM3: infinity adjustment value of focus at zoom position
middle3 (–159<=ZIM3<=61)
AF_I_MID4: ZIM4
ZIM4: infinity adjustment value of focus at zoom position
middle4 (–167<=ZIM4<=77)
AF_I_MID5: ZIM5
ZIM5: infinity adjustment value of focus at zoom position
middle5 (–176<=ZIM5<=92)
AF_I_MID6: ZIM6
ZIM6: infinity adjustment value of focus at zoom position
middle6 (–192<=ZIM6<=101)
– 18 –
x