400 Series
8
Engine timing
Injection timing
Engine
403C-11 Gen-set
403C-11 Gen-set
403C-11 Gen-set
403C-11 Gen-set
403C-11 Industrial
403C-11 Industrial
403C-11 Industrial
403C-11 Industrial
403C-11 Industrial
403C-15 Gen-set
403C-15 Gen-set
403C-15 Gen-set
403C-15 Gen-set
403C-15 Industrial
403C-15 Industrial
403C-15 Industrial
403C-15 Industrial
403C-15 Industrial
404C-22 Gen-set
404C-22 Gen-set
404C-22 Gen-set
404C-22 Industrial
404C-22 Industrial
404C-22 Industrial
404C-22 Industrial
404C-22 Industrial
404C-22T Industrial
If the fuel injection pump is replaced or renewed, the same shim thickness as originally fitted should be used.
The fuel adjustment screw must not be adjusted from the original setting. The maximum no load speed must
be checked after assembly.
No service parts are available for the 400 Series fuel injection pump.
Workshop Manual, TPD 1458E, issue 3 - Perkins Confidential: Green
Maximum rated engine speed rev/min
1500
1800
3000
3600
2200
2400
2600
2800
3000
1500
1800
3000
3600
2200
2400
2600
2800
3000
1500
1800
3000
2200
2400
2600
2800
3000
2800
Operation 8-1
Injection timing (BTDC)
18° ± 1°
18° ± 1°
23° ± 1°
22° ± 1°
23° ± 1°
23° ± 1°
23° ± 1°
23° ± 1°
23° ± 1°
14° ± 1°
14° ± 1°
20° ± 1°
20° ± 1°
22° ± 1°
22° ± 1°
22° ± 1°
20° ± 1°
20° ± 1°
12° ± 1°
12° ± 1°
18° ± 1°
18° ± 1°
18° ± 1°
20° ± 1°
20° ± 1°
20° ± 1°
18° ± 1°
8
69