Whirlpool AWM 295/3 Service Manual page 3

Frontloader
Table of Contents

Advertisement

S E R V I C E
Technical data
Drain pump (synchronus)
Nominal voltage
Nominal current
Nominal consumption
Frequency
Resistor (coil)
Motor protection
Capacity (1.25m height)
Program timer
Type
Hybridtimer with integreated
electronic
Fab.
Nominal voltage
Frequency
Total positions
Cotton/coloured laundry
Pre wash
pos.
Main wash
pos.
Rinse
pos.
Spin
pos.
Stop
pos.
Easy care
Pre wash
pos.
Main wash
pos.
Rinse
pos.
Spin
pos.
Stop
pos.
Delicate
Pre wash
pos.
Main wash
pos.
Rinse
pos.
Spin
pos.
Stop
pos.
Wool
Pre wash
pos.
Main wash
pos.
Rinse
pos.
Spin
pos.
Stop
pos.
Silk
Pre wash
pos.
Main wash
pos.
Rinse
pos.
Spin
pos.
Stop
pos.
Whirlpool Europe
Customer Service
230
V
0.3
A
34
W
50
Hz
155 ± 7%
no
15 ± 2
l/min
EC 4477 (Timer 2a)
230
V
50
Hz
60
01 - 02
03 - 12
13 - 19
20 - 22
23
24 - 26
27 - 34
35 - 39
40 - 41
42
43 - 44
45 - 51
52 - 56
57 - 59
60
-
47 - 51
52 - 56
57 - 59
60
-
49 - 51
52 - 56
57 - 59
60
AWM 295/3
8570 295 53011
Motor
Type
Resistance contacts
6 - 7
4 - 5
2 - 3
1- 3
Radio interference supression
Nominal voltage
Nominal capacity
Nominal inductance
Nominal resistance
Spin selector switch
Positions
Nominal voltage
Value of resistors:
1 - 2 - 3
4 - 6
5 - 6
pos.1
pos.2
pos.3
pos.4
pos.5
pos.6
pos.7
Push button switch
Start stop
Energy save
Hlaf load
Rapid wash
Rinse hold
22.11.1999 / Page 3
Doc. No: 4812 712 14728
MCA 52/64 - 148/WHE0
i = 1 : 13.1
± 7% Ω
68.7
± 7% Ω
2.15
± 7% Ω
1.46
± 7% Ω
0.65
230
V
470nFX1+2x22nFY
2 x 1
mH
680
kΩ
7
5
V
internal shunt
internal shunt
0 Ω
± 5% kΩ
0.68
± 5% kΩ
1.10
± 5% kΩ
1.80
± 5% kΩ
2.70
± 5% kΩ
3.60
± 5% kΩ
4.70
SM
SEC
SHL
SR
SRS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents