5mm
490mm
50mm
850mm
100mm
6
5mm
5mm during operation
500mm for servicing
4.0 Clearances
4.1
Clearances around the boiler (Fig. 10)
1. The minimum clear spaces needed around the
boiler are:
Top:
Bottom: 100mm (4 in)
Sides:
Front:
2. These clearances must not be obstructed in
any way. Blocking the clearance spaces will
result in the appliance overheating and possible
damage may occur.
3. The boiler may be installed in a cupboard if these
minimum clearances are kept. Note that the label
affixed to the front of the boiler must be left in place
to ensure future servicing is successfully
undertaken.
320mm
4. The compartment should be large enough to
house the boiler and ancillary equipment only.
Fig. 10
5. IT SHOULD NOT BE USED AS A STORAGE
CUPBOARD.
6. The gas burning compartment of your boiler is
completely sealed from the room in which it is fitted.
Products from the combustion of gas are vented to
the outside through the flue terminal which must be
kept free from obstruction as this would interfere
with the correct operation of the boiler.
50mm (2 in)
5mm (
3
/
in)
16
5mm (
3/
in)
16