Remote Operation

The Broadway Direct Vent Insert comes equipped with
a thermostatic remote control .
Once a pilot light has been established, and the gas
control knob turned to the "ON" position, the burner may
be turned on or off simply with the remote control.
The remote can be operated in three ways.
1) Manual operation
Simply press the large "UP" or "Down" buttons, the word
"Man" as well as a large arrow in the upper left corner
will be displayed.
To raise the fl ame press the "up" button, and to lower
the fl ame press the "down". In this mode the "auto" and
"Timer" functions are overridden.
Fig# 20
2) Auto / Thermostatic Operation
Push and hold the "Auto" button until the temperature
reading on the hand set display fl ashes. While it is fl ashing
push the large "up" and "down" buttons until the desired
temperature is displayed, wait until the temperature stops
fl ashing. The remote will now check the temperature
of the room every fi ve mins and adjust the fi re to up or
down to suit the temperature you have set.
Fig# 21
Auto
Button
161204-24
3) Timer setting
The third option is to program the fi replace to operate at
set times. It has two "on and "off" cycles which allows
you to program the fi re to come on just before you get
up, shut down just after you leave, be on again when
you get back and the shut down for the night.
Program this feature as follows:
a) Set the temperature as per (2), Auto / Thermostatic
operation , if not already done.
b) Press and hold the "timer" button and it down until
"P1*" is displayed in the handset. When its fl ashing press
the large up and down buttons to set the time you would
like the fi replace to come on in the morning.c) Press
timer again and the P1(moon) will appear, set the time
you wish the fi replace to go off when you leave.
d) Press timer a third time "P2*" will appear, this is the
time you would like the fi replace to come on when you
return, set this again bu using the large up and down
buttons.
e) Press the "timer" button for the fourth and fi nal time, the
"P2 (moon) appears, set the time you wish the fi replace
to go off in the evening using the large "up" and "down"
buttons. Wait until the display stops fl ashing.
"Up"
The on /off times and temperature are now set.The
fi replace will come on and off at the times you have set
and keep the room to the temperature you set.
If you want to override the timer feature, just press "auto"
"Down"
to put you back into thermostat only setting or the large
up and down buttons to put you in manual operation.
Fig# 22
Extend Shutdown:
To shutdown the appliance including the pilot, partially
depress and turn gas control knob clockwise past "PILOT"
to the "OFF" position. DO NOT FORCE.
Flashing
NOTE: The control has an interlock device which
Display
does not allow the pilot to be lit when the appliance is
at operating temperature. Let the appliance cool down
(approx. 60 sec.) before attempting to relight the pilot.
DO NOT use force to rotate the control knob.
Timer
Button
Flashing
Display