Update
Firmware update of the System Access Point and the
free@home devices. The update file contains both the
updates of the System Access Point as well as the up-
dates for all system devices. The update consists of four
steps:
1.
Upload of the firmware to the System Access Point:
Takes place automatically after the update file has
been selected.
2.
Processing the firmware: Takes place automatically
after the successful update. The process can take a
few minutes.
3.
Installing the firmware: Takes place after confirming
the update dialogue. The update takes a few minutes.
After the update has been carried out successfully, the
System Access Point restarts. This could lead to the
website in the Internet browser continuing to indicate
an ongoing update process. An update of the website
(F5 key) rectifies the problem.
4.
Firmware update of all free@home devices connected
to the bus: After confirming the update dialogue, all
free@home devices connected to the bus are updated
automatically. The update is always carried out simul-
taneously on two devices and can be recognized by
the mutual flashing of the LEDs. The process takes
approximately 2 minutes for each device. The system
can be operated as usual during the update.
System Manual
®
05 Types of Devices
Service
Updating all devices: Loads ther current firmware to the
free@home devices. Only necessary if the update of the
devices was rejected during the update dialogue.
Master reset: Resets all free@home devices connected
to the bus to the factory settings. All data backups, user
data, floor plans and time programs are retained.
Resetting the database: Resets the System Access
Point completely or partly to the factory settings. The
selection of the parameters to be reset is made in the
pop-up window