Craftsman 16923 Owner's Manual page 8

Air compressor 10-gallon 1 hp off lubricated
Table of Contents

Advertisement

Available languages

Available languages

Operating
Procedures
Daily Start-Up Procedures
1. Set the Auto-On/Off
lever to the Off position.
2. Inspect the air compressor,
air hose, and any
accessories/tools
being used for damage or
obstruction.
If any of these mentioned items
are in need of repair/replacement,
contact
your local authorized service dealer before
use.
3. Close the drain valve.
4. Check the oil level of the pump.
5. Connect the air hose to the quick connect
socket on the regulator assembly
by inserting
the quick connect plug on the air hose into
the quick connect socket. The quick connect
socket collar will snap forward and lock
the plug into place providing an air tight seal
between the socket and plug. To release the
air hose push the collar back on the quick
connect socket.
i
6. Plug the power cord into the proper receptacle.
7. Turn the Auto-On/Off
lever to the On-Auto
position and the compressor
will start and
build air pressure in the tank to cut-out pressure
and then shut off automatically.
8. Adjust the regulator to a PSI setting that is
needed for your application and be sure it is
within the safety standards required to
perform the task. If using a pneumatic tool,
the manufacturer should have recommendations
in the manual for that particular tool on
operating PSI settings.
9. The air compressor
is now ready for use.
Daily Shut-Down
Procedures
1. Set the Auto-On/Off
lever to the Off position.
2. Unplug the power cord from the receptacle.
3. Set the outlet pressure to zero on the regulator.
4. Remove any air tools or accessories. When
draining the tank, always use ear and eye
protection. Drain the tank in a suitable location;
condensation
will be present in most cases of
draining.
5. Open the drain valve allowing air to bleed from
the tank. After all of the air has bled from
the tank, close the drain valve to prevent
debris buildup in the valve.
When draining the tank, always use ear and eye
protection. Drain the tank in a suitable location;
condensation
will be present in most cases of
draining.
Water that remains
in the tank during storage
will corrode
and weaken
the air tank which could
cause
the tank to rupture.
To avoid serious
injury,
be sure to drain the tank Nter each use or daily.