Summary of Contents for Craftsman CRAFTSMAN 919.167362

  • Page 1: Air Compressor

    • Maintenance • Service and Adjustments • Troubleshooting • Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/craftsman D28409 Rev. 0 1/22/03...
  • Page 2: Table Of Contents

    HOW TO ORDER REPAIR PARTS .....back cover FULL ONE YEAR WARRANTY AIR COMPRESSOR If this air compressor fails due to a defect in material or workmanship within one year from the date of purchase, RETURN IT TO THE NEAREST SEARS REPAIR CENTER THROUGHOUT THE UNITED STATES AND SEARS WILL REPAIR IT, FREE OF CHARGE.
  • Page 3: Specification Chart

    SPECIFICATION CHART Model No. Max. Developed HP Bore Stroke Voltage-Single Phase Minimum Branch Circuit Requirement Fuse Type Air Tank Capacity Approx. Cut-In Approx. Cut-out SCFM @ 40 psig SCFM @ 90 psig SAFETY GUIDELINES - DEFINITIONS This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS.
  • Page 4: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. WARNING: Risk of explosion or fire What Could Happen It is normal for electrical contacts within the motor and pressure switch to spark.
  • Page 5 WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. What Could Happen Failure to properly drain condensed water from tank, causing rust and thinning of the steel tank.
  • Page 6 WARNING: Risk of Electrical Shock WHAT CAN HAPPEN Your air compressor is powered by electricity. Like any other electrically powered device, If it is not used properly it may cause electric shock. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution.
  • Page 7 WARNING: RISK OF BURNS WHAT CAN HAPPEN Touching exposed metal such as the compressor head or outlet tubes, can result in serious burns. WARNING: RISK FROM MOVING PARTS WHAT CAN HAPPEN Moving parts such as the pulley, flywheel, and belt can cause serious injury if they com into contact with you or your clothing.
  • Page 8 RISK OF UNSAFE OPERATION WARNING: WHAT CAN HAPPEN Unsafe operation of your air compressor could lead to serious injury or death to you or others. D28409 HAZARD HOW TO PREVENT IT Review and understand all instructions and warnings in this manual.
  • Page 9: Glossary

    • Air Pressure Regulators Air compressors should be operated on not more than a 50% duty cycle. This means an air compressor that pumps air more than 50% of one hour is considered misuse, because GLOSSARY When the tank pressure drops to a certain low level the motor will restart automatically.
  • Page 10: Installation

    HOW TO SET UP YOUR UNIT Location of the Air Compressor Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air.
  • Page 11 Extension Cords Using extension cords is not recommended. The use of extension cords will cause voltage to drop resulting in power loss to the motor and overheating. Instead of using extension cords attach extra air hoses to each other starting at the air outlet. If an extension cord must be used, be sure it is: •...
  • Page 12: Operation

    "cut-out" pressure. Safety Valve: If the pressure switch does not shut off the air compressor at its "cut-out" pressure setting, the safety valve will protect against high pressure by "popping out" at its factory set pressure (slightly higher than the pressure switch "cut-out"...
  • Page 13: How To Use Your Unit

    Break-in Procedure following break-in instructions are not closely followed. This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced. NOTE: Pull coupler back until it clicks to prevent air from escaping through the quick connect.
  • Page 14 Run the compressor for 15 minutes. Make sure the drain valve is open and there is minimal air pressure build-up in tank. After 15 minutes, close the drain valve (clockwise). The air receiver will fill to "cut-out" pressure and the motor will stop. The compressor is now ready for use.
  • Page 15: Maintenance

    After the water has been drained, close the drain valve (clockwise). The air compressor can now be stored. NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, the reinstalled.
  • Page 16: Service And Adjustments

    SERVICE AND ADJUSTMENTS Unit cycles automatically when power is on. When doing Maintenance, you may be exposed to voltage sources, compressed air or moving parts. Personal injuries can occur. Before performing any Maintenance or repair, unplug the compressor and bleed off all air pressure.
  • Page 17 To Replace Regulator Release all air pressure from air tank. See “To Drain Tank” in the Maintenance section. Unplug unit. Remove the outlet pressure gauge and quick connect (if equipped) from the regulator. Remove the regulator. Outlet Pressure Gauge Quick Regulator Connect Apply pipe sealant tape to the...
  • Page 18: Storage

    Protect the electrical cord and air hose from damage (such as being stepped on or run over). Wind them loosely around the compressor handle. (If so equipped) Store the air compressor in a clean and dry location. 18- ENG Water will condense in the air...
  • Page 19: Troubleshooting Guide

    Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure. PROBLEM...
  • Page 20 PROBLEM Pressure reading It is normal for "some" on the regulated pressure drop to occur. pressure gauge drops when an accessory is used. Compressor is Prolonged excessive use of air. not supplying enough air to Compressor is not large operate accessories.
  • Page 21 PROBLEM Motor will not Fuse blown, circuit breaker run. tripped. Extension cord is wrong length or gauge. Loose electrical connections. Faulty motor. CAUSE Check fuse box for blown fuse and replace as necessary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit.
  • Page 22: Repair Parts

    AIR COMPRESSOR DIAGRAM Air Compressor Model Number 919.167362 Torque 50-60 in.-lbs. Torque 9-12 ft.-lbs. Torque Snug Torque 60-75 in.-lbs. Torque Snug 22- ENG D28409...
  • Page 23: Parts List

    Gauge 2"OD 200PSI 1/8 NPT (2 used) Bushing Reducer 1/8-1/4 NPT Pressure Switch Nipple 1/4-18 NPT Label Specification (Not Shown) Label, Drain Tank Rubber Foot (3 used) Label, Performance Label, Craftsman Label, Hot Surface Label, Warning Eng/Span 23- ENG D28409...
  • Page 24 Air Compressor Model Number 919.167362 D28409 PUMP DIAGRAM 24- ENG 79-4 79-3 79-2...
  • Page 25 Air Compressor Model Number 919.167362 PART NUMBER Z-D27642 SSF-615 SST-3025-1 AC-0108 SSF-586 >x 78 --------- > 79 --------- >x 79-2 AC-0208 > 79-3 ACG-29 >x 79-4 SSF-3158-1 >x 80 SSG-8156 AC-0032 ACG-45 AC-0037 SSF-589 SSF-927 CAC-1173-1 DAC-142 DAC-143 DAC-144 Not Illustrated...
  • Page 26: Español

    GARANTÍA ............26 CUADRO DE ESPECIFICACIONES .
  • Page 27: Cuadro De Especificaciones

    CUADRO DE ESPECIFICACIONES Modelo Nº Máx. HP desarrollado Diámetro interior Carrera Tensión monofásica Circuito mínimo requerido Tipo de fusible Acción retardada Capacidad de aire en el tanque Presión de corte de entrada Presión de corte de salida SCFM a 40 psig SCFM a 90 psig DEFINICIONES DE NORMAS DE SEGURIDAD SEGURIDAD Y PREVENCIÓN DE PROBLEMAS DEL EQUIPO: Para ayudar al...
  • Page 28 INSTRUCCIONES IMPORTANTES DE SEGURIDAD GUARDE ESTAS INSTRUCCIONES LA OPERACIÓN O EL MANTENIMIENTO INADECUADOS DE ESTE PRODUCTO PODRÍAN OCASIONAR SERIAS LESIONES Y DAÑOS A LA PROPIEDAD. LEA Y COMPRENDA TODAS FUNCIONAMIENTO ANTES DE UTILIZAR ESTE EQUIPO. ADVERTENCIA: RIESGO DE EXPLOSIÓN O INCENDIO ¿QUÉ...
  • Page 29 ADVERTENCIA: RIESGO DE EXPLOSIÓN TANQUE DE AIRE: LAS SIGUIENTES CONDICIONES PODRÍAN, CAUSAR EL DEBILITAMIENTO DEL TANQUE, Y DETERMINAR SU EXPLOSIÓN VIOLENTA, DAÑOS A LA PROPIEDAD O SERIAS LESIONES. ¿QUÉ PUEDE OCURRIR? 1. Drenaje inadecuado del agua condensada en el tanque, siendo la causa del óxido que reduce el espesor del tanque de acero.
  • Page 30 ADVERTENCIA: RIESGO DE DESCARGA ELÉCTRICA ¿QUÉ PUEDE OCURRIR? Su compresor de aire está accionado por electricidad. Como cualquier otro dispositivo eléctrico impulsado eléctricamente, si no se lo utiliza adecuadamente, podría causarle una descarga eléctrica. Las reparaciones intentadas por personal no calificado podrían ocasionar serias lesiones o la muerte por electrocución.
  • Page 31 ADVERTENCIA: RIESGO DE QUEMADURAS ¿QUÉ PUEDE OCURRIR? Tocar el metal expuesto tal como el cabezal del compresor o los tubos de salida del escape, puede ocasionarle serias quemaduras. ADVERTENCIA: RIESGO DE PARTES MÓVILES ¿QUÉ PUEDE OCURRIR? Partes movibles tales como la polea, el volante y la correa podrían ser la causa de serias lesiones si ellas entraran en contacto con usted o sus ropas.
  • Page 32 ADVERTENCIA: RIESGO DE OPERACIÓN INSEGURA ¿QUÉ PUEDE OCURRIR? La operacion insegura de su compresor de aire podría ocasionarle serias lesiones o la muerte a usted u otros. D28409 PELIGRO ¿CÓMO PREVENIRLO? Revise y comprenda todas las instrucciones y advertencias contenidas en este manual. Familiarícese con los métodos de operación y control del compresor de aire.
  • Page 33: Glosario

    Familiarícese con los siguientes términos, antes de operar la unidad: CFM: (Cubic feet per minute) Pies cúbicos por minuto. SCFM: (Stardard cubic feet per minute) Pies cúbicos estándar por minuto; una unidad de medida que permite medir la cantidad de entrega de aire. PSIG: (Pound per square inch) Libras por pulgada cuadrada.
  • Page 34: Instalación

    CÓMO PREPARAR LA UNIDAD Ubicación del compresor de aire Ubique al compresor de aire en una zona limpia, seca y bien ventilada. La bomba del compresor de aire y su carcasa han sido diseñadas para permitir un enfriamiento adecuado. Las aberturas de ventilación del compresor resultan - entonces - necesarias para el mantenimiento de una adecuada...
  • Page 35 Cables de extensión eléctrica No se recomienda la utilización de cables de extensión eléctrica. El uso de cables de extensión eléctrica originará una caída de tensión, lo que determinará una pérdida de potencia del motor así como su recalentamiento. En lugar de utilizar un cable de extensión eléctrica, incremente el alcance de la manguera de aire dentro de la zona de trabajo, añadiéndole otro largo...
  • Page 36: Operación

    Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicación de los distintos controles y regulaciones. Conserve este manual para referencias futuras.
  • Page 37 Bomba de compresión del aire (no mostrada): Comprime el aire dentro del tanque. El aire de trabajo no se encuentra disponible hasta que el compresor haya alcanzado a llenar el tanque hasta un nivel de presión por encima del requerido para la salida del aire.
  • Page 38 Luego de 15 minutos, cierre la válvula de drenaje (sentido horario). El aire recibido irá llenando hasta el punto de "corte" de presión, y el motor se detendrá. El compresor estará ahora listo para ser usado. Antes de cada puesta en marcha: Coloque el interruptor On/Auto/Off en la posición "OFF"...
  • Page 39: Mantenimiento

    Responsabilidades del cliente Verifique la válvula de seguridad Drenaje del tanque Cuando se realizan trabajos de mantenimiento, usted puede estar expuesto a fuentes de voltaje, aire comprimido o piezas en movimiento. Pueden ocurrir lesiones personales. Antes de realizar cualquier trabajo de mantenimiento o reparación, desconecte la fuente de energía del compresor y purgue toda la presión de aire.
  • Page 40: Servicios Y Regulaciones

    La unidad cicla automáticamente en cuanto la energía eléctrica es conectada. Al efectuar el mantenimiento, usted quedará expuesto a tensión viva, aire comprimido o partes en movimiento. Debido a tales circunstancias, podrían ocurrirle lesiones personales. Antes de efectuar mantenimiento o reparación alguna, desenchufe el compresor y purgue cualquier presión de aire.
  • Page 41 Para reemplazar el regulador Libere toda la presión del aire del tanque. Vea "Drenaje del tanque" en la sección "Mantenimiento". Desenchufe el equipo. Usando una llave de tuercas ajustable retire el medidor de salida de presión y la conexión rápida del regulador (si la tiene).
  • Page 42: Almacenaje

    Antes de guardar su compresor de aire, asegúrese de hacer lo siguiente: Revise la sección "Mantenimiento" de las páginas precedentes y ejecute el mantenimiento programado de acuerdo a la necesidad. Coloque la palanca On/Auto/Off en la posición "OFF". Gire el regulador en sentido antihorario y fije la presión de salida en cero.
  • Page 43: Guía De Diagnóstico De Problemas

    GUÍA DE DIAGNÓSTICO DE PROBLEMAS El desarrollo de reparaciones puede exponer a sitios con corriente viva, partes en movimiento o fuentes de aire comprimido que podrían ocasionar lesiones personales. Antes de intentar reparación alguna, desenchufe el compresor de aire y purgue toda la presión de aire del tanque.
  • Page 44 PROBLEMA Es normal que ocurra algún La lectura de la descenso en la presión. presión sobre un manómetro (si viene equipado con éste) desciende cuando se utiliza un accesorio. El compresor no Excesivo y prolongado uso del esta aire. suministrando suficiente El compresor no tiene cantidad de aire...
  • Page 45 PROBLEMA El motor no Fusible fundido; interruptor funciona. automático del circuito disparado. El cable de extensión eléctrica tiene una longitud o calibre erróneo. Conexiones eléctricas sueltas. Falla el motor. CAUSA Verifique la caja de fusibles observando la existencia de fusibles fundidos y sustitúyalos en caso de necesidad.
  • Page 46: Notes/Notas

    NOTES/NOTAS 46- SP D28409...
  • Page 47: Notes/Notas

    NOTES/NOTAS 47- SP D28409...
  • Page 48 Get it fixed, at your home or ours! For repair – in your home – of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner’s manuals that you need to do-it-yourself.